Order by:   Filter results: 
Web Code Reference Description Category Price
19165 93392 KNX occupancy detector with integrated KNX bus connector PD11-KNX-FLAT-DX SENSORS
  • Low profile KNX occupancy detector with integrated KNX bus connector
  • 1x Light (for regulating or switching), 1x slave output, 3 separate HVAC-blocs
  • HVAC mode (1=comfort, 2=stand-by, 3=economy, 4 = antifreeze/heat protection)
  • Intelligent semi-automatic mode, occupancy-independent regulating mode (photoelectric switch), full automatic mode
  • Individual adaption of the motion sensor sensitivity
  • Detection area can be extended thanks to master-slave-mode
  • Extensive optimization options for light measurement
  • Measured light value is communicated to the bus
  • Adaption of dimming curve
  • Measuring of mixed light thanks to internal light sensor
  • Determination of the reflection factor, e.g. on a desk, with the optional Infrared Luxmeter IR-LM
  • IR remote control-capable via IR remote control (optionally)
  • PIN code
  • Burn-in function for fluorescent lamps selectable from 1h till 100h
  • Various locking functions
  • Status LEDs can be activated / deactivated
  • IR remote control-capable via 5 button remote control, programmable at choice (accessory)
  • Programming button (phys. address) can be operated via remote control
  • Regulation/switching of three light groups via offset (external influence possible)
  • Manual influence via external KNX push buttons possible
  • Function control (heartbeat, cyclical sending)
  • Short presence, self-adjusting follow-up time, corridor function
  • Soft-start
  • Occupancy simulation
  • Forced switch-off
  • Two logic modules
  • Intelligent central-off function
  • Recall of light scenes
  • Premonition of switch-off
  • Behaviour upon bus voltage return definable at choice
  • Variable safety pause after switching off the lights
  • ??Temperature- and noise sensor
  • Settings ex ETS 4 for integration in KNX systems
  • The product database for import into the ETS database can be downloaded from the B.E.G. homepage.
  • Spring clips for quick and easy installation in suspended ceilings
  • Includes blinds and clamp ring for installation in lightsApplication examples: offices, schools, nursery schools, hospitals, conference rooms.
  • 19165
    93392 KNX OCCUPANCY DETECTOR WITH INTEGRATED KNX BUS CONNECTOR PD11-KNX-FLAT-DX SENSORS
    19207 93365 Binary input or output device (4X push button interface) PBM-KNX-DX-4W INPUTS
    • Binary input or output device (push button interface) for pattress boxes (60 mm)
    • User-friendly ETS interface
    • Settings ex ETS 4 for integration in KNX systems
    • The product database for import into the ETS database can be downloaded from the B.E.G. homepage.


    Supply voltage: 21 - 31 V DC of the KNX bus

    Dimensions: 38 x 41 x 12 mm

    Nominal current: 9.5 mA (typ.) (Imax parametrierbar 12.5 mA bzw. 20 mA)

    Degree of protection / Class: IP20 / Class III

    Operating temperature: -5 ° C to +45 ° C

      Programming LED

    Connection type: 2 x 1 mm null Connector: 8 pin

      Imax 3.6 mA konst. (PWM) LED 3.5 V / 4 mA




    Manufacturer: B.E.G. Brück Electronic GmbH
    Color:
    Reference: 93365
    Name: PBM-KNX-DX-4W

    19207
    93365 BINARY INPUT OR OUTPUT DEVICE (4X PUSH BUTTON INTERFACE) PBM-KNX-DX-4W INPUTS
    19209 93381 KNX presence detector with integrated KNX-BUS interface PD2N-KNX-BA-UP SENSORS
    KNX presence detector with integrated KNX-BUS interface Flush-mounted version Parameterization as of ETS 4 for integration in KNX systems The product database for import into the ETS database can be downloaded from the B.E.G. homepage.
    19209
    93381 KNX PRESENCE DETECTOR WITH INTEGRATED KNX-BUS INTERFACE PD2N-KNX-BA-UP SENSORS
    19214 93382 KNX presence detector with integrated KNX-BUS coupler Ceiling installation DETECTORS
    KNX presence detector with integrated KNX-BUS coupler Ceiling installation version Parameterization as of ETS 4 for integration in KNX systems The product database for import into the ETS database can be downloaded from the B.E.G. homepage.
    19214
    93382 KNX PRESENCE DETECTOR WITH INTEGRATED KNX-BUS COUPLER CEILING INSTALLATION DETECTORS
    19217 93383 KNX presence detector with integrated KNX-BUS coupler flush-mounted version DETECTORS
    KNX presence detector with integrated KNX-BUS interface Flush-mounted version Parameterization as of ETS 4 for integration in KNX systems The product database for import into the ETS database can be downloaded from the B.E.G. homepage.
    19217
    93383 KNX PRESENCE DETECTOR WITH INTEGRATED KNX-BUS COUPLER FLUSH-MOUNTED VERSION DETECTORS
    19660 92719 KNX mini occupancy detector with integrated bus connector TIME TRANSMITTERS - SWITCHES
    • KNX mini occupancy detector with integrated bus connector
    • 1x Light (for regulating or switching), 1x slave output, 3 separate HVAC-blocs
    • HVAC mode (1=comfort, 2=stand-by, 3=economy, 4 = antifreeze/heat protection)
    • Intelligent semi-automatic mode, occupancy-independent regulating mode (photoelectric switch), full automatic mode
    • Individual adaption of the motion sensor sensitivity
    • Detection area can be extended thanks to master-slave-mode
    • Extensive optimization options for light measurement
    • Measured light value is communicated to the bus
    • Adaption of dimming curve
    • Measuring of mixed light thanks to internal light sensor
    • Determination of the reflection factor, e.g. on a desk, with the optional IR-BT-Adapter
    • IR remote control-capable via IR remote control (optionally)
    • PIN code
    • Burn-in function for fluorescent lamps selectable from 1h till 100h
    • Various locking functions
    • Status LEDs can be activated / deactivated
    • IR remote control-capable via 5 button remote control, programmable at choice (accessory)
    • Programming button (phys. address) can be operated via remote control
    • Regulation/switching of three light groups via offset (external influence possible)
    • Manual influence via external KNX push buttons possible
    • Function control (heartbeat, cyclical sending)
    • Short presence, self-adjusting follow-up time, corridor function
    • Soft-start
    • Occupancy simulation
    • Forced switch-off
    • Two logic modules
    • Intelligent central-off function
    • Recall of light scenes
    • Premonition of switch-off
    • Behaviour upon bus voltage return definable at choice
    • Variable safety pause after switching off the lights
    • Temperature sensor
    • Settings ex ETS 4 for integration in KNX systems
    • The product database for import into the ETS database can be downloaded from the B.E.G. homepage.
    • Typical applications:
      Offices, conference rooms, schools, nursery schools, hospitals
    19660
    92719 KNX MINI OCCUPANCY DETECTOR WITH INTEGRATED BUS CONNECTOR TIME TRANSMITTERS ...
    19724 93385 PD4N-KNX-ST KNX occupancy detector FLUSH MOUNT DETECTORS
    KNX occupancy detector with integrated KNX bus connector
        1x Light (for regulating or switching), 1x slave output, 3 separate HVAC blocs
        Intelligent semi-automatic mode, occupancy-independent regulating mode (photoelectric switch), full automatic mode
        Individual adaption of detection sensitivity for each PIR sensor
        Direction of movement can be identified
        Adaptation of dimming curve
        Mixed light measurement with internal and external light sensor
        Determination of the reflection factor, e.g. on a desk, with the optional BLE-IR adapter
        Burn-in function for fluorescent lamps selectable from 1h to 100h
        Various locking functions
        Status LEDs can be activated / deactivated
        Programming button can be operated via remote control
        Regulation / switching of three light groups via offset (external influence possible)
        Short presence, self-adjusting follow-up time, corridor function
        Soft-start
        Recall of light scenes
        HVAC mode (1 = comfort, 2 = standby, 3 = economy, 4 = antifreeze / heat protection)
        PIR sensors can be deactivated individually
        Detection area can be extended thanks to master-slave-mode
        Extensive optimization options for light measurement
        Measured light value is communicated to the bus
        IR remote control-capable via IR remote control (optional)
        PIN code
        Manual influence via external KNX push buttons possible
        Function control (heartbeat, cyclical sending)
        Forced switch-off
        Intelligent central-off function
        Premonition of switch-off
        Behavior on bus voltage definitive at choice
        Variable safety break after switching off the lights
        Settings ex ETS 4 for integration into KNX systems
        The product database for the ETS database can be downloaded from the B.E.G. homepage.
        Spring clamps
        blinds
        Typical applications:
        monitoring of large areas like underground garages, gyms, warehouses, loading ramps, halls
    19724
    93385 PD4N-KNX-ST KNX OCCUPANCY DETECTOR FLUSH MOUNT DETECTORS
    19208 93380 KNX occupancy detector with integrated KNX bus connector SENSORS
    • KNX occupancy detector with integrated KNX bus connector
    • Full automatic mode
    • 1x light (for switching), 1 separate HVAC bloc
    • Measuring of mixed light thanks to internal light sensor
    • Various locking functions
    • Status LEDs can be activated / deactivated
    • Behaviour upon bus voltage return definable at choice
    • Settings ex ETS 4 for integration in KNX systems
    • The product database for import into the ETS database can be downloaded from the B.E.G. homepage.
    • Spring-clamps
    • Blinds
    • Application examples:
      corridors, halls, staircases, storage rooms, cellars, toilet
    •  

    • Voltage :

      24 V DC
      Dimensions:
      FC= Ø 83 x 55 mm
      FM= Ø 106 x 42 mm
      typ. power input :
      12 mA
      Detection area :
      vertical 360°
      Range :
      max. Ø 10 m across
      max. Ø 6 m towards
      max. Ø 4 m smaller movements
      Monitored surface, when the detector is mounted at the recommended height and for tangential approach :
      79 m²
      Mounting height min./max./recommended:
      2 m / 5 m / 2.5 m
      Degree / class of protection :
      FC= IP20 / Class II
      FM= IP20 / Class II
      Ambient temperature :
      -25 °C to +55 °C
      Housing :
      Polycarbonate, UV-resistant
      Number of light sensors:
      1
      Number of PIR sensors:
      1
      Brightness set value :
      5 - 2000 Lux
    19208
    93380 KNX OCCUPANCY DETECTOR WITH INTEGRATED KNX BUS CONNECTOR SENSORS
    19210 93360 KNX occupancy detector with integrated KNX bus connector DETECTORS
    KNX occupancy detector with integrated KNX bus connector
    1x Light (for regulating or switching), 1x slave output, 3 separate HVAC-blocs
    HVAC mode (1=comfort, 2=stand-by, 3=economy, 4 = antifreeze/heat protection)
    Intelligent semi-automatic mode, occupancy-independent regulating mode (photoelectric switch), full automatic mode
    Individual adaption of the motion sensor sensitivity
    Detection area can be extended thanks to master-slave-mode
    Extensive optimization options for light measurement
    Measured light value is communicated to the bus
    Adaption of dimming curve
    Mixed light measurement with internal and external light sensor
    Determination of the reflection factor, e.g. on a desk, with the optional Infrared Luxmeter IR-LM
    IR remote control-capable via IR remote control (optionally)
    PIN code
    Burn-in function for fluorescent lamps selectable from 1h till 100h
    Various locking functions
    Status LEDs can be activated / deactivated
    Programming button (phys. address) can be operated via remote control
    Regulation/switching of three light groups via offset (external influence possible)
    Manual influence via external KNX push buttons possible
    Function control (heartbeat, cyclical sending)
    Short presence, self-adjusting follow-up time, corridor function
    Soft-start
    Forced switch-off
    Intelligent central-off function
    Recall of light scenes
    Premonition of switch-off
    Behaviour upon bus voltage return definable at choice
    Variable safety pause after switching off the lights
    ??Temperature- and noise sensor
    Settings ex ETS 4 for integration in KNX systems
    The product database for import into the ETS database can be downloaded from the B.E.G. homepage.
    Spring-clamps
    19210
    93360 KNX OCCUPANCY DETECTOR WITH INTEGRATED KNX BUS CONNECTOR DETECTORS
    19213 93361 KNX presence detector with integrated KNX-BUS interface Flush-mounted DETECTORS

    KNX presence detector with integrated KNX-BUS interface Flush-mounted version Presence simulation Parameterization from ETS 4 onwards for integration in KNX systems The product database for import into the ETS database can be downloaded from the B.E.G. homepage.

    https://www.beg-luxomat.com/es/productos/luxomatnet/knx/detectores-de-presencia-serie-deluxe-knx-dx/pd2n-knx-dx/

    19213
    93361 KNX PRESENCE DETECTOR WITH INTEGRATED KNX-BUS INTERFACE FLUSH-MOUNTED DETECTORS
    19725 93307 Surface mounting set IP54 for PD2N and PD4N flush-mount devices OTHER ACCESSORIES
  • Surface mounting set IP54 for PD2N and PD4N flush-mount devices
  • The SM mounting set is suitable for the following KNX Generation 6 devices:
  •  PD2N-KNX-ST-FM
     PD2N-KNX-DX-FM
     PD2N-KNX-BA-FM
     PD4N-KNX-ST-FM
     PD4N-KNX-DX-FM
     PD4N-KNX-K-DX-FM
  •  

    19725
    93307 SURFACE MOUNTING SET IP54 FOR PD2N AND PD4N FLUSH-MOUNT DEVICES OTHER ACCESSORIES
    19817 92979 KNX multifunction Room Controller GATEWAYS
    Pre-wired control unit for KNX occupancy detectors and other loads for being mounted in a false ceiling
        Gateway DALI/KNX for connecting up to 45 DALI lights
        GST18 plugs and sockets
        Pre-wiring allows for cost savings and prevents erroneous installations
        The integrated service switch allows for using (basic functions) the connected loads even without ETS
        All B.E.G. KNX motion and occupancy detectors can be combined with the KNX-RCT
        Already integrated are a DALI gateway, a roller shutter actuator and two push button interfaces
    19817
    92979 KNX MULTIFUNCTION ROOM CONTROLLER GATEWAYS
    19839 93362 Indoor presence detector 180-KNX-BA without frame DETECTORS
    Automatic mode
    The parameterization to ETS 4 for the integration in KNX systems
    The product database for importing into the ETS system can be downloaded from the B.E.G. website.
    For the combination with cover frame (measurements of the inner cover 50 x 50 mm) in 5 different colors
    Examples of applications: monitoring of public facilities, toilets, corridors, libraries, meeting rooms
    Technical data
    Supply voltage:
    of the KNX bus
    Dimensions:
    (without bezel) 70 x 70 x 61 mm
    Rated current:
    12 mA
    Detection angle:
    horizontal 180 °
    Scope:
    max. 10 m cross
    max. 3 m frontal
    Cross coverage area:
    157 m² / 1,1 m Assembly height
    19839
    93362 INDOOR PRESENCE DETECTOR 180-KNX-BA WITHOUT FRAME DETECTORS
    19841 93363 KNX occupancy detector with integrated KNX bus coupler, especially for installation in walls DETECTORS

    KNX occupancy detector with integrated KNX bus coupler, especially for installation in walls
    1x Light (for regulating or switching), 1x slave output, 3 separate HVAC-blocs
    Intelligent semi-automatic mode, occupancy-independent regulating mode (photoelectric switch), full automatic mode
    Individual adaption of the motion sensor sensitivity
    Adaption of dimming curve
    Measuring of mixed light thanks to internal light sensor
    Determination of the reflection factor, e.g. on a desk, with the optional BLE-IR-Adapter
    Burn-in function for fluorescent lamps selectable from 1h till 100h
    Various locking functions
    Status LEDs can be activated / deactivated
    Programming button (phys. address) can be operated via remote control
    Regulation/switching of three light groups via offset (external influence possible)
    Short presence, self-adjusting follow-up time, corridor function
    Soft-start
    Recall of light scenes
    HVAC mode (1=comfort, 2=stand-by, 3=economy, 4 = antifreeze/heat protection)
    Detection area can be extended thanks to master-slave-mode
    Extensive optimization options for light measurement
    Measured light value is communicated to the bus
    IR remote control-capable via IR remote control (optionally)
    PIN code
    Manual influence via external KNX push buttons possible
    Function control (heartbeat, cyclical sending)
    Forced switch-off
    Intelligent central-off function
    Premonition of switch-off
    Behaviour upon bus voltage return definable at choice
    Variable safety pause after switching off the lights
    Settings ex ETS 4 for integration in KNX systems
    The product database for import into the ETS database can be downloaded from the B.E.G. homepage.
    For use with covering (interior cover dimensions 50x50mm) in 5 different colours
    In combination with centre plates usable with current frame systems of various manufacturers
    B.E.G. frames and centre plates for combination with other frame systems available
    Please order cover frame separately, available in various colours
    Application examples: monitoring of public lavatories, corridors, archive rooms, conference rooms

    Voltage:
    via KNX BUS
    Dimensions:
    (covering not included) 70 x 70 x 61 mm
    typ. power input:
    12 mA
    Detection area:
    horizontal 180°
    Range:
    max. 10 m across
    max. 3 m towards
    Monitored area (tangential movement):
    157 m² / 1,1 m Mounting height
    Mounting height min./max./recommended:
    1 m / 2,2 m / 1,1 m
    Degree / class of protection:
    IP20 / Class III
    Ambient temperature:
    -25 °C to +55 °C
    Housing:
    Polycarbonate, UV-resistant
    Number of light sensors:
    1
    Number of PIR sensors:
    1
    Orientation light:
    5 - 100 % / OFF / 1 min - 255 min
    Night light:
    5 - 100 %
    Brightness set value:
    5 - 2000 Lux
    19841
    93363 KNX OCCUPANCY DETECTOR WITH INTEGRATED KNX BUS COUPLER, ESPECIALLY FOR INSTALLATION IN WALLS DETECTORS


    KNX SPECIAL CATALOGUES
    Different looks for KNX push buttons
    Push buttons
    Smart metering
    MDT Catalog 2017
    Iddero Verso Interactive Presentation

    LEARN
    Free webinars
    uBrick Tutorials
    VideoTutorials CBSE


    PARTICIPATE
    µBrick Trivia
    KNX Tips & tricks
    TEST
    Free test of CBSE visualization

    LATEST KNX NEWS
    All news

    LATEST KNX OFFERS
    All offers
    DOWNLOADS
    KNX - All brands

    FUTURASMUS KNX GROUP
    Contact
    Location
    Futurasmus in the world
    FOLLOW US
    YouTube Channel
    Facebook
    LinkedIN
    Google+
    Twitter

    KNX++ TRAINING CENTER
    Futurasmus Zentrum

    CERTIFIED KNX TEST LAB
    Futurasmus KNX Lab
    SPECIALIZED KNX WHOLESALER CERTIFIED KNX TRAINING CENTRE
    Futurasmus KNX Group is a highly specialized and internationally active KNX Wholesaler, being our forte the excellent technical support we provide. You can visit our online catalogue in this website and, if you are a professional, ask for a non binding offer for your KNX projects. Should you be interested in buying KNX components, you are welcome to read our General Sales Conditions and contact our technicians and commercial agents per telephone, e-mail or online help. Since 2003 we have been a Certified Training Centre KNX++, which means that we are entitled to impart the KNX Basic Course as well as the KNX Advanced Course and KNX Tutor Course. We are manufacturer-independent and also offer other specialized and monographic KNX seminars. After teaching more than 1.500 KNX partners, our KNX Trainers have quite a large and positive expertise. Please, contact us for customized KNX training worldwide (groups of at least 8 people) at training@futurasmus-knxgroup.org
    USE OF COOKIES
    We use our own and third-party cookies, analyzing your browsing habits in out website, with the finality of ensuring the quality, security and improvement of the offered services through the same. In the case that the user does not explicitly state whether to accept the installation of cookies, but continues using our website, it will mean that he has consented expressly, informing him about the possibility to block or remove the installed cookies on his computer by configuring the appropriate settings of the browser. You can get more information on this subject reading our "Cookies Policy".