Order by:   Filter results: 
Web Code Reference Description Category Price
16254 UIM-KNX 42 KNX USB interface, programming, 2U SYSTEM DEVICES
• The USB interface enables bidirectional communication / data connection between PC and the KNX TP bus
•.ETS
•.commissioning of bus devices
•.visualisation,
•.protocol
•.diagnosis
• Any software based on FALCON (ETS3, ETS4, ETS5, EITT etc.) communicates via flexible common EMI protocol through UIM-KNX 42 with other devices in the network.
• The intelligent USB interface supports long telegrams (max 228 bytes) as well as Raw Frames – a special diagnostic mode.
• Modular installation device for 35mm DIN rails
16254
UIM-KNX 42 KNX USB INTERFACE, PROGRAMMING, 2U SYSTEM DEVICES
16255 MECtp Interface LINE COUPLER, 2TE MRDC SYSTEM DEVICES

The MECtp commonly known as “line coupler” is the first member of our family of media coupling devices. The basic functionality of MECtp is coupling a mainline “Twisted pair “ with a sub line “Twisted pair”.
MECtp provides galvanic isolation between the two connected lines. Due to the flexibility of MECtp , the coupler can be used as a line coupler to connect a line with a main line or a backbone coupler to connect a main line with a backbone line. The main task of MECtp is filtering the traffic according the installation place in the hierarchy or according to the built in filter tables for group oriented communication.
The MECtp provides outstanding features compared to other similar products, for example support for long messages (up to 250 byte length) and a configurable one button activation of special functions. These are helpful during installation, during run time and for trouble shooting. The high informative 6 duo LED display shows accurate the bus status on each line. This helps identifying common communication problems due to bus load or retransmissions on both lines.

Available functions are:
- suppress device configuration on the sub line
- enable or disable filtering of group messages
- suppress device oriented messages
- trace the traffic on the sub line
- reduced number of retransmissions

16255
MECTP INTERFACE LINE COUPLER, 2TE MRDC SYSTEM DEVICES
18236 IPS640 640mA Power Supply with diagnostic functions 2U size SYSTEM DEVICES

With a very small footprint of only 2 units (36mm) our new KNX power supply unit IPS640 with diagnostics is the smallest of its kind for KNX in the the marketplace. The highly-efficient device features an additional auxiliary power output (e.g. to support individual components). Both outputs are overload and short circuit protected. The IPS640 generates a stable KNX system voltage of 30 V DC and the integrated choke decouples the bus line from the auxiliary output. Any desired load distribution on the outputs is possible.

The duo-LED display of the IPS640 indicates the state of the power supply unit and the bus line. The device reset can be triggered over the bus by a communication object or directly at the device by a single button press. All configurations can be done with the ETS software. For diagnostic purposes bus voltage, bus current, device temperature and several times of operation are monitored. Additionally all details (number, duration) on events like short-circuit, overload, load disconnection, device startup and reset are easily accessible.

The info data of the IPS640 can be read out via the KNX bus. It can be sent on demand, at adjustable time intervals and after a certain change in value. It can also be sent after a faulty behaviour event and on crossing a pre-set threshold value. Number and duration of these over threshold events are available information as well. When the IPS640 returns to normal working condition (after bus reset, device startup, short circuit) the readout is sent automatically. The alarm functionality can be used to switch other devices.

All above mentioned features can be activated and deactivated by the user. When activated the IPS640 monitors the values of relevant measurements. For details on alarm functionality and switching othe devices ase download our "Technical and Application Description".

18236
IPS640 640MA POWER SUPPLY WITH DIAGNOSTIC FUNCTIONS 2U SIZE SYSTEM DEVICES


KNX SPECIAL CATALOGUES
Different looks for KNX push buttons
Push buttons
Smart metering
Iddero Verso Interactive Presentation

LEARN
Free webinars
uBrick Tutorials
VideoTutorials CBSE


PARTICIPATE
µBrick Trivia
KNX Tips & tricks
TEST
Free test of CBSE visualization

LATEST KNX NEWS
All news

LATEST KNX OFFERS
All offers
DOWNLOADS
KNX - All brands

FUTURASMUS KNX GROUP
Contact
Location
Futurasmus in the world
FOLLOW US
YouTube Channel
Facebook
LinkedIN
Google+
Twitter

KNX++ TRAINING CENTER
Futurasmus Zentrum

CERTIFIED KNX TEST LAB
Futurasmus KNX Lab
SPECIALIZED KNX WHOLESALER CERTIFIED KNX TRAINING CENTRE
Futurasmus KNX Group is a highly specialized and internationally active KNX Wholesaler, being our forte the excellent technical support we provide. You can visit our online catalogue in this website and, if you are a professional, ask for a non binding offer for your KNX projects. Should you be interested in buying KNX components, you are welcome to read our General Sales Conditions and contact our technicians and commercial agents per telephone, e-mail or online help. Since 2003 we have been a Certified Training Centre KNX++, which means that we are entitled to impart the KNX Basic Course as well as the KNX Advanced Course and KNX Tutor Course. We are manufacturer-independent and also offer other specialized and monographic KNX seminars. After teaching more than 1.500 KNX partners, our KNX Trainers have quite a large and positive expertise. Please, contact us for customized KNX training worldwide (groups of at least 8 people) at training@futurasmus-knxgroup.org
USE OF COOKIES
We use our own and third-party cookies, analyzing your browsing habits in out website, with the finality of ensuring the quality, security and improvement of the offered services through the same. In the case that the user does not explicitly state whether to accept the installation of cookies, but continues using our website, it will mean that he has consented expressly, informing him about the possibility to block or remove the installed cookies on his computer by configuring the appropriate settings of the browser. You can get more information on this subject reading our "Cookies Policy".