Order by:   Filter results: 
Web Code Reference Description Category Price
8137 70157 KNX PY Pyranometer FOR knx SENSORS
KNX PY Pyranometer for KNX/EIB
Measures the global radiation. With 4 limit values and logic gates (AND
and OR). Output of a mixed value from own and external value. Configuration
with ETS software. With combined fixture for wall/pole mounting, with
2 brackets for pole mounting. Delivery with installation instructions5
8137
70157 KNX PY PYRANOMETER FOR KNX SENSORS
18995 70704 PC interface: KNX RF USB stick RF

 PC interface: KNX RF USB stick

It connects a PC with the KNX system via KNX RF radio. The user gets comfortable access to KNX RF directly from his windows-based computer.

The USB stick is easily operated in a USB slot of the computer. Via the ETS software from version 5, devices are addressed and programmed or diagnosis are made via the USB stick. The KNX RF USB Stick is a practical tool for the installation of KNX systems.

For example, the radio remote control Remo KNX RF can be used with KNX RF in the KNX system.

Please note: You will need a media coupler for connecting KNX TP and KNX RF, like the KNX RF LC-TP.

18995
70704 PC INTERFACE: KNX RF USB STICK RF
19054 70401 sensor for temperature and humidity (with dew point) Mini-Sewi KNX TH SENSORS

The Sensors Mini-Sewi KNX T and Mini-Sewi KNX TH measures the ambient temperature. Mini-Sewi KNX TH additionally captures the air humidity and calculates the dew-point. Via the bus, the indoor sensors can receive external values of temperature or humidity and process them further with their own data to a total value (mixed value, e.g. room average).

All measurement values can be used for the control of limit-dependent switching outputs. States can be linked via AND logic gates and OR logic gates. In addition, an integrated actuating variable comparator can compare and output variables that were received via communication objects.

An integrated PI-controller controls a heating/cooling (according to temperature). Mini-Sewi KNX TH offers a second controller for ventilation (humidification/dehumidification according to humidity) and a warning can be output to the bus as soon as the comfort field, as per DIN 1946, is left

19054
70401 SENSOR FOR TEMPERATURE AND HUMIDITY (WITH DEW POINT) MINI-SEWI KNX TH SENSORS
19055 70402 Mini-Sewi KNX TH-Pr Presence Detector with Temperature/Humidity Sensor and dew point. SENSORS

The Sensor Mini-Sewi KNX TH-Pr detects motion. It measures the temperature and the air humidity and calculates the dew-point. Via the bus, the indoor sensor can receive external values of temperature and humidity and process them further with its own data to a total value (mixed value, e.g. room average).

All measurement values can be used for the control of limit-dependent switching outputs. States can be linked via AND logic gates and OR logic gates. In addition, an integrated actuating variable comparator can compare and output variables that were received via communication objects.

Integrated PI-controllers control ventilation (humidification/dehumidification according to humidity) and heating/cooling (according to temperature). The Mini-Sewi KNX TH-Pr can output a warning to the bus as soon as the comfort field, as per DIN 1946, is left.

19055
70402 MINI-SEWI KNX TH-PR PRESENCE DETECTOR WITH TEMPERATURE/HUMIDITY SENSOR AND DEW POINT. SENSORS
5667 3095 Suntracer KNX basic 230 VAC SENSORS

Sensor for brightness, wind, precipitation, temperature. With logic gates.

 

Brightness measurement: The current light intensity is measured by means of a sensor.

Wind measurement: The measurement of wind speed is accomplished electronically and thus noiseless and reliable even in case of hail, snow and minus temperature. Air swirls and up-draught in the radius of the weather station are collected, too.

Precipitation perception: The surface of the sensor is heated so that only drops and flakes are recognised as precipitation but not fog or dew. If it stops raining or snowing, the sensor dries quickly and the precipitation message ends.

Temperature measurement

Threshold values can be adjusted per parameter or via communication objects

8 AND and 8 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits.

Configuration is accomplished by means of the KNX software ETS.

5667
3095 SUNTRACER KNX BASIC 230 VAC SENSORS
5688 3090 SUNTRACER GPS light KNX 230V CA Meteorological Station for KNX/EIB SENSORS
The Suntracer KNX weather station:

* Measures temperature, wind speed and brightness.

* Recognize precipitation and receive the RF DCF77 signal for the date and time.

* Also, calculate the exact position of the sun (azimuth and elevation), as well as the coordinates of location and time.


In the very compact box, there are the sensors, the analysis electronics and the Bus couplers.

The measurement values ??are sent to the KNX Bus as physical values ??in the EIS 5 format. The position of the sun is also transmitted to the Bus and calculated based on the date, time and location parameter.

The measured values ??and the calculated values ??are available in the form of communication objects for various switching outputs that are switched independently of their threshold values. The threshold values ??themselves can be established either by parameters or by means of communication objects.

The weather station has an integrated annual and weekly time switch whose switching outputs can be used as communication objects. The weekly time switch switches up to 4 different time intervals for each day of the week. With the annual time switch you can also establish 3 periods distributed throughout the year in which a maximum of 2 daily on / off times can be given. Switching hours
they can be established either by parameters or by means of communication objects.

There are also 8 logical AND gates and 8 OR logic gates, each with 4 inputs. Various switching events can be used as inputs for the logic gates, as well as 8 logic inputs (in the form of communication objects). The output of each gate can be configured as desired: as 1 Bit or as 2 x 8 Bit.
5688
3090 SUNTRACER GPS LIGHT KNX 230V CA METEOROLOGICAL STATION FOR KNX/EIB SENSORS
6034 70131 Actuators KNX S-B4T-UP: 4 binary inputs, 1 input for temperature sensor ( T-KTY82). ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows
Available for 24 V DC motors or 230 V motors (motor connection of the
230V models with microfuse T6,3 A). Configuration with ETS software. For
assembly in a flush mounted socket. Delivery with installation instructions5.
6034
70131 ACTUATORS KNX S-B4T-UP: 4 BINARY INPUTS, 1 INPUT FOR TEMPERATURE SENSOR ( T-KTY82). ACTUATORS - OUTPUTS
6035 70133 Actuators KNX S-B2-UP 230 VAC 2 BINARY ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows  Available for 24 V DC motors or 230 V motors (motor connection of the  230V models with microfuse T6,3 A). Configuration with ETS software. For assembly in a flush mounted socket. Delivery with installation instructions

6035
70133 ACTUATORS KNX S-B2-UP 230 VAC 2 BINARY ACTUATORS - OUTPUTS
6036 70135 Actuators KNX S-UP 230 VAC , without additional inputs ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows  Available for 24 V DC motors or 230 V motors (motor connection of the 230V models with microfuse T6,3 A). Configuration with ETS software. For  assembly in a flush mounted socket. Delivery with installation instructions5.
6036
70135 ACTUATORS KNX S-UP 230 VAC , WITHOUT ADDITIONAL INPUTS ACTUATORS - OUTPUTS
6037 70134 Actuators KNX S-UP 24 VDC ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows  Available for 24 V DC motors or 230 V motors (motor connection of the 230V models with microfuse T6,3 A). Configuration with ETS software. For  assembly in a flush mounted socket. Delivery with installation instructi
6037
70134 ACTUATORS KNX S-UP 24 VDC ACTUATORS - OUTPUTS
6038 70130 Actuators KNX S-B4T-UP 24V ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows
Available for 24 V DC motors or 230 V motors (motor connection of the
230V models with microfuse T6,3 A). Configuration with ETS software. For
assembly in a flush mounted socket. Delivery with installation instructions5.
6038
70130 ACTUATORS KNX S-B4T-UP 24V ACTUATORS - OUTPUTS
6039 70132 KNX/EIB Actuators KNX S-B2-UP 24V ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows
Available for 24 V DC motors or 230 V motors (motor connection of the
230V models with microfuse T6,3 A). Configuration with ETS software. For
assembly in a flush mounted socket. Delivery with installation instructions5
6039
70132 KNX/EIB ACTUATORS KNX S-B2-UP 24V ACTUATORS - OUTPUTS
6040 70122 KNX Meteorological Sensors KNX W 230 VAC SENSORS
With logic gates (AND and OR). Configuration with ETS software. With combined fixture for wall/pole mounting, with 2 brackets for pole mounting. Delivery with installation instructions
6040
70122 KNX METEOROLOGICAL SENSORS KNX W 230 VAC SENSORS
6041 70123 KNX Meteorological Sensors KNX W 24VDC SENSORS
The Wind Sensor KNX W electronically measures the wind speed and transfers the value to the KNX system. Three switching outputs with adjustable threshold values as well as additional AND and OR logic gates are available.
The sensor system, the evaluation electronics and the electronics of the bus connection are mounted in a compact housing.
6041
70123 KNX METEOROLOGICAL SENSORS KNX W 24VDC SENSORS
6044 70126 KNX Meteorological Sensors RW 230VAC SENSORS
The rain/wind sensor KNX RW measures precipitation and wind speed and transfers the values to the KNX system. Four switching outputs with three adjustable threshold values as well as additional AND and OR logic gates are available. The sensor system, the evaluation electronics and the electronics of the bus connection are mounted in a compact housing
6044
70126 KNX METEOROLOGICAL SENSORS RW 230VAC SENSORS
6045 70127 KNX RW 24VDC Rain/Wind Sensor for KNX/EIB. SENSORS
KNX Meteorological Sensors With logic gates (AND and OR). Configuration with ETS software. With combined fixture for wall/pole mounting, with 2 brackets for pole mounting. Delivery with installation instructions5. Suitable 20 VAC power supply unit for 24 V DC (20 VAC
6045
70127 KNX RW 24VDC RAIN/WIND SENSOR FOR KNX/EIB. SENSORS
6046 70128 KNX LW 230VAC Light/Wind Sensor for KNX/EIB. SENSORS
KNX Meteorological Sensors With logic gates (AND and OR). Configuration with ETS software. With combined fixture for wall/pole mounting, with 2 brackets for pole mounting. Delivery with installation instructions5. Suitable 20 VAC power supply unit for 24 V DC (20 VAC)
6046
70128 KNX LW 230VAC LIGHT/WIND SENSOR FOR KNX/EIB. SENSORS
6047 70129 KNX Meteorological Sensors KNX LW 24VDC SENSORS
KNX Meteorological Sensors With logic gates (AND and OR). Configuration with ETS software. With combined fixture for wall/pole mounting, with 2 brackets for pole mounting. Delivery with installation instructions5. Suitable 20 VAC power supply unit for 24 V DC (20 VAC) model
6047
70129 KNX METEOROLOGICAL SENSORS KNX LW 24VDC SENSORS
6117 3096 Suntracer KNX basic 24 V DC (20 VAC) SENSORS
Meteorological Station for KNX/EIB
With wind sensor, heated rain sensor (1.2 W), sun sensor and outdoor temperature
sensor. AND and OR logic gates. Configuration with ETS software.
With combined fixture for wall/pole mounting, with 2 brackets for
pole mounting.
Suitable 20 VAC power supply unit for 24 V DC (20 VAC) model: Nº 2018.
6117
3096 SUNTRACER KNX BASIC 24 V DC (20 VAC) SENSORS
6331 70140 KNX PS640 for bus voltage and 24 V DC, Reset by means of the key pad possible SYSTEM DEVICES
KNX PS640 Power Supply Systems for KNX/EIB  The power supplies deliver a 29 V bus voltage for the KNX/EIB system and  24 V DC supply voltage for 24 V devives. Output currant max. 640 mA. With  display and key pad. For assembly on a top hat rail.
6331
70140 KNX PS640 FOR BUS VOLTAGE AND 24 V DC, RESET BY MEANS OF THE KEY PAD POSSIBLE SYSTEM DEVICES
8071 70151 KNX SO250Tank Sensor for KNX/EIB SENSORS
KNX SO250Tank Sensor for KNX/EIB
For measurement of the capacity of liquids in tanks and for distance measurement.
KNX interface, 2 output relays. Configuration with ETS software.
Evaluation unit with display and key pad, assembly on top hat rail.
Cable length of measuring sensor 10 m. Delivery with installation instructions5
8071
70151 KNX SO250TANK SENSOR FOR KNX/EIB SENSORS
8136 70141 KNX PS640 Power Supply Systems SYSTEM DEVICES
KNX PS640 Power Supply Systems for KNX/EIB  The power supplies deliver a 29 V bus voltage for the KNX/EIB system and 24 V DC supply voltage for 24 V devives. Output currant max. 640 mA. With display and key pad. For assembly on a top hat rail.
KNX PS640 for bus voltage and 24 V DC, Reset by means of the key pad possible.
8136
70141 KNX PS640 POWER SUPPLY SYSTEMS SYSTEM DEVICES
8138 70121 KNX T-AP Temperature Sensor for KNX/EIB SENSORS

The Temperature Sensor KNX T-AP measures temperature in indoor and outdoor areas. The sensor can receive an external measured value via the bus and process it with the own data to an overall temperature (mixed value).
The KNX T-AP provides four switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling

  • Measurement of temperature
  • Mixed value from own measured value and external value (proportions can be set in percentage)
  • PI controller for heating (one or two step) and cooling (one or two step)
  • 4 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
  • 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
  • Configuration is made by using the KNX software ETS
8138
70121 KNX T-AP TEMPERATURE SENSOR FOR KNX/EIB SENSORS
9032 3094 Suntracer KNX-GPS light Weather station for KNX with GPS receiver SENSORS
The Weather Station Suntracer KNX-GPS light measures temperature, wind speed and brightness. It perceives precipitation and receives the GPS signal for time and position. Furthermore, the exact position of the sun (azimuth and elevation) is calculated on the basis of location coordinates and time.

All data may be used for the control of switching outputs which depend on threshold values. The states may be linked by means of AND and OR logic gates.

The compact housing of Suntracer KNX-GPS light stores the sensor system, the evaluation electronics and the electronics of the bus connection.


Functions and Operation:

· Brightness and position of the sun: The current light intensity is measured by means of a sensor. At the same time, Suntracer KNX-GPS light calculates the position of the sun (azimuth and elevation) on the basis of time and location

· Wind measurement: The measurement of wind speed is accomplished electronically and thus noiseless and reliable even in case of hail, snow and minus temperature. Air swirls and up-draught in the radius of the weather station are collected, too

· Precipitation perception: The surface of the sensor is heated so that only drops and flakes are recognised as precipitation but not fog or dew. If it stops raining or snowing, the sensor dries quickly and the precipitation message ends

· Temperature measurement

· Week and calendar time switch: The weather station receives time and date from the integrated GPS receiver. The week time switch operates up to 4 different periods each day. With the calendar time switch, you may determine 3 additional periods where the time switch accomplishes up to 2 activations and deactivations each day. The Switching outputs can be used as communication objects. The switching times are set by parameter or via communication objects

· Switching outputs for all measured and calculated values (Threshold values can be set by parameter or via communication objects)

· 8 AND and 8 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits

· Configuration is accomplished by means of the KNX software ETS



9032
3094 SUNTRACER KNX-GPS LIGHT WEATHER STATION FOR KNX WITH GPS RECEIVER SENSORS
9360 70142 KNX PS640-IP Router / Power Supply System SYSTEM DEVICES
The Power Supply System KNX PS640-IP combines the central functions of a KNX bus line: Power supply with throttle, IP router and IP interface:
The Power Supply Unit of the KNX PS640-IP delivers a 29 V bus voltage for the KNX system and 24 V DC supply voltage for 24 V devices.
Special operating conditions such as short circuit, electrical surge, overcharge or excess temperature are recorded and may be read off on the display. The present power discharge is displayed as well. It is possible to reset the connected bus devices directly by means of the key pad.

The IP router of the KNX PS640-IP allows for forwarding of telegrams between different lines via a rapid LAN (IP) backbone. The KNX PS640-IP therfore also takes on the function of a line coupler.

In parallel, the KNX PS640-IP can be used as interface for accessing the bus access via IP. Like this, the KNX system can be configuered and supervised from any PC in the LAN (Tunnelling).
9360
70142 KNX PS640-IP ROUTER / POWER SUPPLY SYSTEM SYSTEM DEVICES
9404 3093 Suntracer KNX-GPS Weather Station SENSORS
The Weather Station Suntracer KNX-GPS measures temperature, wind speed and brightness. It perceives precipitation and receives the GPS signal for time and position. Furthermore, the exact position of the sun (azimuth and elevation) is calculated on the basis of location coordinates and time.

All data may be used for the control of switching outputs which depend on threshold values. The states may be linked by means of AND and OR logic gates.

The compact housing of Suntracer KNX-GPS stores the sensor system, the evaluation electronics and the electronics of the bus connection.

Functions and Operation:

· Brightness and position of the sun: The current light intensity is measured by means of a sensor. At the same time, Suntracer KNX-GPS calculates the position of the sun (azimuth and elevation) on the basis of time and location

· Shading control for up to 6 fronts with tracking of the slats and shadow edge

· Wind measurement: The measurement of wind speed is accomplished electronically and thus noiseless and reliable even in case of hail, snow and minus temperature. Air swirlsand up-draught in the radius of the weather station are collected, too

· Precipitation perception: The surface of the sensor is heated so that only drops and flakes are recognised as precipitation but not fog or dew. If it stops raining or snowing, the sensor dries quickly and the precipitation message ends

· Temperature measurement

· Week and calendar time switch: The weather station receives time and date from the integrated GPS receiver. The week time switch operates up to 4 different periods each day. With the calendar time switch, you may determine 3 additional periods where the time switch accomplishes up to 2 activations and deactivations each day. The Switching outputs can be used as communication objects. The switching times are set by parameter

· Switching outputs for all measured and calculated values (Threshold values can be set by parameter or via communication objects)

· 8 AND and 8 OR logic gates with each 4 inputs. Every switching incident as well as 16 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits

· Configuration is accomplished by means of the KNX software ETS
9404
3093 SUNTRACER KNX-GPS WEATHER STATION SENSORS
9506 70119 Brightness Sensor KNX L
Brightness Sensor | Light Sensor | Sun Sensor
SENSORS
The brightness sensor measures the intensity of illumination and transfers the value to the KNX system. Six switching outputs with adjustable threshold values as well as additional AND and OR logic gates are available.
The sensor system, the evaluation electronics and the electronics of the bus connection are mounted in a compact housing.

Functions and Operation:

Brightness measurement: The current light intensity is measured by a sensor

3 switching outputs for twilight (up to 1000 lux), 3 for daylight (1-99 klux), each with adjustable threshold values (Threshold values can be set by parameter or via communication objects)

8 AND and 8 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits

Configuration is accomplished by means of the KNX software ETS
9506
70119 BRIGHTNESS SENSOR KNX L
BRIGHTNESS SENSOR | LIGHT SENSOR | SUN SENSOR
SENSORS
9986 70184 KNX TH65-AP Thermo-Hygrometer SENSORS
The KNX TH65-AP for KNX measures temperature and air humidity in indoor or outdoor areas and may be used for the prescribed monitoring of store rooms, stables or green houses.

In passive houses, the thermo-hygrometer checks the inlet of the outer air in automatic ventilation systems or it controls the comfort field according to DIN 1946.

Besides the calculation of mixed values, adjustable switching outputs and logic gates, the KNX TH65-AP offers a PI control for heating, cooling and ventilation.

The device is mounted on-wall and connected to the KNX bus system.
9986
70184 KNX TH65-AP THERMO-HYGROMETER SENSORS
10042 70220 KNX T-UN temperature sensor, IP 68, -30…+130°C SENSORS
The Temperature Sensor KNX T-UN consists of evaluation electronics and measuring sensor. The sensor measures temperature in indoor and outdoor areas. The sensor can receive an external measured value via the bus and process it with the own data to an overall temperature (mixed value). The KNX T-UN provides four switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling.
Functions:
• Measurement of temperature
• Mixed value from own measured value and external value (proportions can be set in percentage)
• PI controller for heating (one or two step) and cooling (one or two step)
• 4 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
• 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
10042
70220 KNX T-UN TEMPERATURE SENSOR, IP 68, -30…+130°C SENSORS
12314 70221 KNX T-UN temperature sensor, IP 43, -35…+100°C SENSORS
The Temperature Sensor KNX T-UN consists of evaluation electronics and measuring sensor. The sensor measures temperature in indoor and outdoor areas. The sensor can receive an external measured value via the bus and process it with the own data to an overall temperature (mixed value). The KNX T-UN provides four switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling.
Functions:
• Measurement of temperature
• Mixed value from own measured value and external value (proportions can be set in percentage)
• PI controller for heating (one or two step) and cooling (one or two step)
• 4 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
• 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
12314
70221 KNX T-UN TEMPERATURE SENSOR, IP 43, -35…+100°C SENSORS
15795 70154 Suntracer KNX SL Weather Station for KNX SENSORS
With wind sensor, heated precipitation sensor (1.2 W), brightness sensor, outdoor temperature sensor, air pressure sensor and GPS receiver. Calculation of the position of the sun. Calendar time switch, week time switch. Shading control for 8 fronts with tracking of the slats and shadow edge and with frost protection. Logic gates (AND/OR). 4 comparators. Configuration with ETS software. Auxiliary voltage: 12…40 V DC (12…28 V AC). With combined fixture for wall/pole mounting, incl. clip for pole mounting. With installation instructions.
15795
70154 SUNTRACER KNX SL WEATHER STATION FOR KNX SENSORS
15803 70382 Vari KNX 3L, 3 brightness sensors, rotated 90° each SENSORS
Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.
Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.
15803
70382 VARI KNX 3L, 3 BRIGHTNESS SENSORS, ROTATED 90° EACH SENSORS
15816 70383 Vari KNX 3L, 3 brightness sensors, rotated 90° each, temperature sensor, IP44 SENSORS

Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.


Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15816
70383 VARI KNX 3L, 3 BRIGHTNESS SENSORS, ROTATED 90° EACH, TEMPERATURE SENSOR, IP44 SENSORS
15817 70384 Vari KNX 3L, 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, IP44 SENSORS


Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15817
70384 VARI KNX 3L, 3 BRIGHTNESS SENSORS, ROTATED 90° EACH, TEMPERATURE SENSOR, HUMIDITY SENSOR, IP44 SENSORS
15818 70385 KNX Temperature sensor, IP44 SENSORS


Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15818
70385 KNX TEMPERATURE SENSOR, IP44 SENSORS
15819 70386 KNX Temperature sensor, humidity sensor, IP44 SENSORS

Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15819
70386 KNX TEMPERATURE SENSOR, HUMIDITY SENSOR, IP44 SENSORS
15820 70388 KNX temperature sensor, humidity sensor, air pressure sensor., IP44 SENSORS

Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15820
70388 KNX TEMPERATURE SENSOR, HUMIDITY SENSOR, AIR PRESSURE SENSOR., IP44 SENSORS
15821 70389 KNX 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor., IP44 SENSORS

Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15821
70389 KNX 3 BRIGHTNESS SENSORS, ROTATED 90° EACH, TEMPERATURE SENSOR, HUMIDITY SENSOR, AIR PRESSURE SENSOR., IP44 SENSORS
15864 70387 KNX GPS receiver TIME TRANSMITTERS - SWITCHES

Output of UTC, local time, mounting position. Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

15864
70387 KNX GPS RECEIVER TIME TRANSMITTERS ...
16714 70390 KNX 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor., IP44 SENSORS

Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

16714
70390 KNX 3 BRIGHTNESS SENSORS, ROTATED 90° EACH, TEMPERATURE SENSOR, HUMIDITY SENSOR, AIR PRESSURE SENSOR., IP44 SENSORS
19053 70400 temperature sensor Mini-Sewi KNX T SENSORS

The Sensors Mini-Sewi KNX T and Mini-Sewi KNX TH measures the ambient temperature. Mini-Sewi KNX TH additionally captures the air humidity and calculates the dew-point. Via the bus, the indoor sensors can receive external values of temperature or humidity and process them further with their own data to a total value (mixed value, e.g. room average).

All measurement values can be used for the control of limit-dependent switching outputs. States can be linked via AND logic gates and OR logic gates. In addition, an integrated actuating variable comparator can compare and output variables that were received via communication objects.

An integrated PI-controller controls a heating/cooling (according to temperature). Mini-Sewi KNX TH offers a second controller for ventilation (humidification/dehumidification according to humidity) and a warning can be output to the bus as soon as the comfort field, as per DIN 1946, is left.

19053
70400 TEMPERATURE SENSOR MINI-SEWI KNX T SENSORS
17072 70392 Sewi KNX Temperature sensor SIN FAMILIA

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.
Sewi KNX T Temperature sensor

 

17072
70392 SEWI KNX TEMPERATURE SENSOR SIN FAMILIA
17073 70393 Sewi KNX Wall/Ceiling Sensors, Combined sensor for temperature and air humidity SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX TH Combined sensor for temperature and air humidity

17073
70393 SEWI KNX WALL/CEILING SENSORS, COMBINED SENSOR FOR TEMPERATURE AND AIR HUMIDITY SENSORS
17074 70394 Sewi KNX AQS CO2-Sensor SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX AQS CO² sensor

17074
70394 SEWI KNX AQS CO2-SENSOR SENSORS
17075 70395 Sewi KNX Wall/Ceiling Sensors, Brightness sensor SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX L Brightness sensor

17075
70395 SEWI KNX WALL/CEILING SENSORS, BRIGHTNESS SENSOR SENSORS
17076 70396 Sewi KNX Wall/Ceiling Sensors, Brightness sensor with presence detector SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX L-Pr Brightness sensor with presence detector

17076
70396 SEWI KNX WALL/CEILING SENSORS, BRIGHTNESS SENSOR WITH PRESENCE DETECTOR SENSORS
17077 70397 Sewi KNX Wall/Ceiling Sensors, Combined sensor for CO², temperature, humidity, and air pressure SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX AQS/TH-D Combined sensor for CO², temperature, humidity, and air pressure

17077
70397 SEWI KNX WALL/CEILING SENSORS, COMBINED SENSOR FOR CO², TEMPERATURE, HUMIDITY, AND AIR PRESSURE SENSORS
17079 70398 Sewi KNX Wall/Ceiling Sensors, Combined sensor for temperature, humidity, brightness and presence detection SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX Wall/Ceiling Sensors, CCombined sensor for temperature, humidity, brightness and presence detection

 

17079
70398 SEWI KNX WALL/CEILING SENSORS, COMBINED SENSOR FOR TEMPERATURE, HUMIDITY, BRIGHTNESS AND PRESENCE DETECTION SENSORS
17080 70399 Sewi KNX Wall/Ceiling Sensors, Combined sensor for CO², temperature, humidity, air pressure, brightness, SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

 

Sewi KNX AQS/TH-D L-Pr Combined sensor for CO², temperature, humidity, air pressure, brightness,presence detection

 

 

17080
70399 SEWI KNX WALL/CEILING SENSORS, COMBINED SENSOR FOR CO², TEMPERATURE, HUMIDITY, AIR PRESSURE, BRIGHTNESS, SENSORS
17447 70405 SALVA KNX basic Smoke Detector ALARMS CENTRAL

Smoke alarm sensors with optical detection based on the scattered light principle, certified according to EN 14604:2005/AC:2008 and 1172-CPR-150013. Local acoustic alarm signal output (warning sound at least 85 dB) and transfer to KNX bus. Local alarm acknowledgement
Signalling of smoke alarm
Smoke chamber pollution measurement and pollution display according to UL directive 
Power supply via battery (9 V). Lack of battery capacity is signalled optically and acoustically for 30 days and transmitted to the bus
High operative safety due to elaborate automatic self-testing of the entire electronics and separate energy measurement
Faults signalled locally and via the bus
High deceptive alarm immunity due to powerful measuring chamber and consideration of temperature fluctuations (though no temperature smoke alarm) 
8 AND and 8 OR logic gates each with 4 inputs. All switching events as well as 16 logic inputs (in the form of communications objects) can be used as inputs for the logic gates. The output from each gate can be configured optionally as 1-bit or 2 x 8-bit
8 multi-function modules (computers) for changing the input data by calculations, by querying a condition or by converting the data point type
4 actuating variable comparators to output minimum, maximum or average values. 5 inputs each for values received via communication objects


Additional functions for Salva KNX TH:

Signalling of heat alarms 
Temperature sensor and air humidity sensor with mixed value calculation, dewpoint calculation, comfort field query (DIN 1946)
Threshold values for measured and calculated values, adjustable via parameters or communication objects
PI control for heating/cooling (depending on temperature)
PI controller for ventilation (depending on air humidity)

17447
70405 SALVA KNX BASIC SMOKE DETECTOR ALARMS CENTRAL
10037 70195 KNX Touch One - 5,7" Colour touch display VISUALIZATION

https://www.youtube.com/watch?v=udtEHLr81pc

5,7" Colour touch display with advanced functions for the control of façades and HVAC.

- Available with frame in aluminium/graphite or White/grey
- Surface mounting
- Light, dimmer, blind control, etc
- Automatic functions for façade and HVAC control (ventilation, heating, air conditioning) customized by the final user.
- Temperature and humidity measurement.
- Time programming.
- Scenes.
- 4 free potential binary inputs (up to 50meter cable)
- Integrated KNX bus coupler
- Optionally, RF control remote with 8 channels:
o Magnetic wall mounting.
o Available in aluminium or white

10037
70195 KNX TOUCH ONE - 5,7" COLOUR TOUCH DISPLAY VISUALIZATION
16717 70320 Heating Actuator for KNX, 4 outputs. CLIMATE CONTROL

The KNX K actuators have got internal temperature controllers and output channels for controlling heating or cooling systems. The temperature controllers can control both the outputs on the KNX K and other climate control system on the KNX Bus.

In automatic mode, the temperature controllers are set at nominal temperatures for different modes. This way, it is easy to switch between the modes, comfort, standby, eco and building protection. The switch is made via an object e. g. via a manual switch, time switch or sensor switch outputs in the KNX-System.

The buttons on the device allow for direct manual switching of the connected systems. LEDs show whether the output channel was manually operated or is running in an automatic mode.

16717
70320 HEATING ACTUATOR FOR KNX, 4 OUTPUTS. CLIMATE CONTROL
11337 70244 KNX VOC-UP basic Mixed Gas SENSORS

The Mixed Gas Sensor KNX VOC-UP basic recognizes volatile organic compounds in the room air. The indoor sensor can receive an external VOC value via the bus and process it with the own data to an overall value (mixed value, e. g. room average).

The KNX VOC-UP basic provides four switching outputs with adjustable threshold values. The switching outputs and further communication objects can be linked by AND and OR logic gates. Additionally, an integrated actuating variable comparator can compare and output values that are received via communication objects.
An integrated PI controllers allows for control of ventilation depending on VOC concentration.

The housing is completed with a frame of the switching series installed in the building and thus merges with the interior.

Functions and Operation:

  • Measurement of VOC (volatile organic compounds) in the air. In this process, an air quality value in CO2 eqivalents is calculated via an algorithm from the sum signal of all componds included in the mixed gas.
  • Mixed value from own measured value and external value (proportions can be set in percentage)
  • PI controller for ventilation depending on VOC concentration: dehumidification/humidification (one step) or dehumidification (one or two step)
  • 4 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
  • 8 AND and 8 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
  • 2 actuating variable comparators for output of minimum, maximum or avarage values
  • Configuration is accomplished by means of the KNX software ETS
11337
70244 KNX VOC-UP BASIC MIXED GAS SENSORS
11923 70310 KNX I4-ERD Evaluation Unit for Ground Sensors TH-ERD SENSORS

Evaluation unit KNX I4-ERD for monitoring of ground temperature/humidity. For up to 4

Ground Sensors TH-ERD. 2 threshold values for temperature/humidity per sensor. Installationon DIN rail. Operating voltage 230 V AC. Delivery with installation instructions4. Suitable

ground temperature/humidity sensor: TH-ERD (optional), cable length 10 m.

11923
70310 KNX I4-ERD EVALUATION UNIT FOR GROUND SENSORS TH-ERD SENSORS
11931 70144 KNX PS640+USB with bus functions SYSTEM DEVICES

The Power Supply Systems KNX PS640+ and KNX PS640+USB deliver a 29 V bus voltage for the KNX system and 24 V DC supply voltage for 24 V devices. The KNX PS640+USB has got an additional USB interface for easy bus access.

Special operating conditions such as short circuit, electrical surge, overcharge or excess temperature are recorded and may be read off on the display. The present power discharge is displayed as well. It is possible to reset the connected bus devices directly by means of the key pad.

In addition all functions can be realised via the bus, too, e. g. the transfer of malfunction messages and operating data and a time/period reset. Malfunction messages are stored by the KNX PS640+(USB).

Functions and Operation:

  • Delivers a 29 V KNX bus voltage (reduced), output current max. 640 mA, short-circuit proof
  • Delivers 24 V DC (not reduced), output current max. 150 mA
  • Reset of a line directly on the device
  • Record of operating hours, overload, external overvoltage, internal overvoltage, short circuit and excess temperature
  • Display of operating data bus voltage, bus current and temperature of the device
  • The display may be shown in German, English, Spanish or Dutch
  • Bus connection for data transfer (e. g. malfunction messages, operating data)
  • Possibility for reset and diagnostics via the bus
  • Only KNX PS640+USB: USB interface for bus access via PC

Technical Data:

HousingPlastic material
ColourWhite
MountingSnap-on fitting on mounting rails
Protection categoryIP 20
Dimensionsapprox. 123 x 89 x 61 (W x H x D, mm), 7 width units
Weightapprox. 370 g
Ambient temperatureOperation -5…+45 °C, storage -25…+70°C
Ambient air humiditymax. 95% RH, avoid bedewing
Operating voltage230 V AC , 50 Hz
Outputs• KNX bus voltage 29 Volt (reduced),
Output current max. 640 mA, short-circuit proof
• 24 V DC (not reduced), Output current max. 150 mA
• KNX data
Data outputKNX +/- bus terminal plug
Communication objects27

Scope of Delivery:

  • Rail-mounted device with display and keypad
  • Data sheet with installation instruction and description of parameter setting (German or English)
  • Product file VD2 (German, English, Spanish) as download
11931
70144 KNX PS640+USB WITH BUS FUNCTIONS SYSTEM DEVICES
12300 70258 Corlo Touch,Touch Display for KNX, 3,5", white, with crhome-plated glossy edge VISUALIZATION

Touch display usable as a switch, for the setting of automatic functions and display of information.

Touch sensitive surface 3.5 inches. RGB frame illumination. Integrated proximity sensor and brightness sensor. Internal automatic functions for control of shading, room conditioning (heating, cooling, ventilation), lighting. 4 inputs (binary inputs or for temperatures sensor T-PT, Nº 30515). Micro SD card slot. USB interface. Installation in a socket.

Operating voltage 12...40 V DC. Delivery with installation instructions4.

Available in white or black. Please order display with edge to match the frame (glossy/matt).

Corlo Touch KNX: KNX connection for data communication.

Corlo Touch KNX WL: KNX connection. Connector for W-LAN stick.

Frame Corlo: Available as 1-, 2- or 3-gang frame, glossy or matt chrome-plated.

12300
70258 CORLO TOUCH,TOUCH DISPLAY FOR KNX, 3,5", WHITE, WITH CRHOME-PLATED GLOSSY EDGE VISUALIZATION
12304 70252 Corlo Touch, Touch Display for KNX. 3,5". Integrierte Wi-Fi, white, with chrome-plated glossy edge VISUALIZATION

Touch display usable as a switch, for the setting of automatic functions and display of information.

Touch sensitive surface 3.5 inches. RGB frame illumination. Integrated proximity sensor and brightness sensor. Internal automatic functions for control of shading, room conditioning (heating, cooling, ventilation), lighting. 4 inputs (binary inputs or for temperatures sensor T-PT, Nº 30515). Micro SD card slot. USB interface. Installation in a socket. Operating voltage 12...40 V DC. Delivery with installation instructions4.

Available in white or black. Please order display with edge to match the frame (glossy/matt).

Corlo Touch KNX: KNX connection for data communication.

Corlo Touch KNX WL: KNX connection. Connector for W-LAN stick.

Frame Corlo: Available as 1-, 2- or 3-gang frame, glossy or matt chrome-plated.

12304
70252 CORLO TOUCH, TOUCH DISPLAY FOR KNX. 3,5". INTEGRIERTE WI-FI, WHITE, WITH CHROME-PLATED GLOSSY EDGE VISUALIZATION
12316 70153 Tank Sensors for KNX SO250 basic SENSORS

Functions and Operation:

  • Distance measurement
  • Level measurement (filling volume or height) in ball, cubical and cylindrical
    tanks. Several tanks of the same type set up as a bank
  • 5 switched outputs with variable thresholds (thresholds are set optionally by parameters or via communication objects)
  • Setting of bus functions by means of the KNX software ETS
12316
70153 TANK SENSORS FOR KNX SO250 BASIC SENSORS
12971 70222 KNX T6-UN-B4 temperature evaluation unit SENSORS

The KNX T6-UN-B4 temperature evaluation unit has six inputs for T-100 or T-130 temperature sensors and four analogue/digital inputs, which can for example be used for buttons or T-NTC temperature sensors. The temperature measurement values for all inputs can be processed with external measurement values to provide a combined value (total temperature, average temperature).

The KNX T6-UN-B4 provides six switched outputs with adjustable threshold values. Six PI controllers control the heating and cooling (one- or two-stage). Logic gates can be used to set up additional operations.

12971
70222 KNX T6-UN-B4 TEMPERATURE EVALUATION UNIT SENSORS
14642 70350 Temperature sensors for KNX SENSORS

Thermometer for indoor applications. 4 threshold values, logic gates (AND/OR). Output of a mixed value from own and external value. PI controller for heating/cooling. Configuration with ETS software. Operating voltage: bus voltage.

Available in 4 colours: white glossy (simital to RAL 9016), aluminium matt, antracite matt, stainless stell matt. For installation in a socket. Frame not included. With installation instructions.

 

14642
70350 TEMPERATURE SENSORS FOR KNX SENSORS
14646 70282 Single push buttons, with integrated Temperature Sensor PUSH BUTTONS

The Single switch Corlo M1-T and the Double switch Corlo M2-T are mechanical switches for the Corlo system. A sensor for measuring the room temperature is integrated into both switches.
The switch contacts and the temperature sensor output may be used for the conventional installation and, for example, relay controls and PLC. The temperature contact is also ideally suited for a connection to the Corlo Touch KNX display.

14646
70282 SINGLE PUSH BUTTONS, WITH INTEGRATED TEMPERATURE SENSOR PUSH BUTTONS
14652 70286 M2-T Double Push Button, with sensor temperatura, 2 fold PUSH BUTTONS

Single or double push button for  System Corlo. Glass surface in black or white, Please order push button with edge to match the frame (custom coloured edge/frame on request)

Corlo Push Button M-T with integrated temperature sensor T-NTC. Available as single push button Corlo M1-T and as double push button Corlo M2-T.

14652
70286 M2-T DOUBLE PUSH BUTTON, WITH SENSOR TEMPERATURA, 2 FOLD PUSH BUTTONS
14924 70145 KNX PS640+IP WITH BUS FUNCTIONS AND ETHERNET INTERFACE SIN FAMILIA

The power supplies deliver a 29 V bus voltage for the KNX system and 24 V DC supply voltage for 24 V devices. Output current max. 640 mA. With display and key pad. Reset on the device possible. Installation on DIN rail.

KNX PS640: without bus functions.
KNX PS640+: with bus functions (transfer of malfunction messages/operating, time/period reset via the bus).
KNX PS640 USB: without bus functions. With USB interface.
KNX PS640+USB: with bus functions (transfer of malfunction messages/operating data, time/period reset via the bus) and USB interface.
KNX PS640-IP: without bus functions. With Ethernet interface (RJ45 connector). Allows for routing (Ethernet as fast backbone for KNX data), use as line coupler, tunneling (bus access over IP).
KNX PS640+IP: with bus functions (transfer of malfunction messages/operating data, time/period reset via the bus) and Ethernet interface (RJ45 connector). Allows for routing (Ethernet as fast backbone for KNX data), use as line coupler, tunneling (bus access over IP).

14924
70145 KNX PS640+IP WITH BUS FUNCTIONS AND ETHERNET INTERFACE SIN FAMILIA
15796 70155 Suntracer KNX sl light Weather Station for KNX SENSORS

With wind sensor, heated precipitation sensor (1.2 W), brightness sensor, outdoor temperature sensor and GPS receiver. Calculation of the position of the sun. Calendar time switch, week time switch. Shading control for 5 fronts. Logic gates (AND/OR). 4 comparators. Configuration with ETS software. Auxiliary voltage: 12…40 V DC (12…28 V AC). With combined fixture for wall/pole mounting, incl. clip for pole mounting. With installation instruction

The Suntracer KNX sl light weather station for the bus system of edi-
ficio KNX measures temperature, wind speed and brightness. Detect price
calls and receives the GPS signal for time and location. At the same time,
calculates the exact position of the sun (azimuth and elevation) with the coordinates of the
and the moment

All values ??can be used for the control of switching outputs dependent on
teeth limit values. States can be associated by means of logic gates Y and
logical doors O. If necessary, multifunctional modules modify the data
input through calculations, query of a condition or conversion of the type of points
to data.
Integrated shading control allows intelligent control of the screen
solar of up to five facades.
In the compact housing of the Suntracer KNX sl light there are sensors, electronic
evaluation system and bus coupling electronics.


Functions:


• Brightness measurement (current light intensity)
• GPS receiver with indication of the current time and the coordinates of the
site. At the same time, the Suntracer weather station
KNX sl light calculates the position of the sun (azimuth and elevation)


• Shading control for up to 5 facades


• Wind measurement: Wind speed is measured electronically and from
Silent and reliable way, even with hail, snow and subzero temperatures.
It also captures air turbulence and rising winds, within the range of
scope of the device


• Precipitation detection: The surface of the sensor is heated, so
that only drops and flakes are recognized as precipitation, but not
fog or dew. If it stops raining or snowing, the sensor dries quickly and the
rain alarm ceases


• Temperature measurement


• Anti-frost protection for shading


• Weekly timer and calendar: All switching outputs of
time can be used as communication objects.
The weekly timer has 24 time intervals. Each interval
time can be parameterized as output or as input If the period of
time is an output, the switching time will be determined by
parameter or by communication object.
The calendar timer has 4 time intervals. For each
interval of time can be determined two connections / disconnections that
they are made daily


• Switching outputs for all measured and calculated values.
Adjustable limit values ??by means of parameters or objects of
communication


• 8 logical AND doors and 8 logical OR doors with 4 inputs, respectively.
As inputs for the logic gates you can use all the events of
switching and the 16 logical inputs in the form of communication objects.
The output of each gate can be configured as a 1 or 2 x 8 bit bit.


• 8 multifunctional modules (calculators) for data modification of
input through calculations, by consulting a condition or by
conversion of the type of data point


• Summer compensation for cooling. Through a curve
Feature adapts the temperature specified in the room to the temperature
outside and the minimum and maximum value of the temperature is determined
specified


The configuration is done through the KNX ETC Software. The product file
is available for download on the Elsner Elektronik homepage at www.el-
sner-elektronik.de in the "Downloads" menu.

15796
70155 SUNTRACER KNX SL LIGHT WEATHER STATION FOR KNX SENSORS
15797 70156 SUNTRACER KNX sl basic Weather Station for KNX SENSORS
With wind sensor, heated precipitation sensor (1.2 W), 3 brightness sensors (rotated 90° each), outdoor temperature sensor. Logic gates (AND/OR). 4 comparators. Configuration with ETS software. Auxiliary voltage: 12…40 V DC (12…28 V AC). With combined fixture for wall/pole mounting, incl. clip for pole mounting. With installation instructions.
15797
70156 SUNTRACER KNX SL BASIC WEATHER STATION FOR KNX SENSORS
15798 70158 Wind sensor for KNX W sl SENSORS

With logic gates (AND/OR). Configuration with ETS software. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Auxiliary voltage: 12…40 V DC (12…28 V AC). With installation instructions.
KNX W sl: Wind Sensor for KNX.

KNX R sl: Rain Sensor for KNX.

KNX RW sl: Rain/Wind Sensor for KNX.

KNX LW sl: Brightness/Wind Sensor for KNX.

15798
70158 WIND SENSOR FOR KNX W SL SENSORS
15800 70162 Rain/wind sensor for KNX RW sl SENSORS
With logic gates (AND/OR). Configuration with ETS software. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Auxiliary voltage: 12…40 V DC (12…28 V AC). With installation instructions.
KNX W sl: Wind Sensor for KNX.KNX R sl: Rain Sensor for KNX.KNX RW sl: Rain/Wind Sensor for KNX.KNX LW
15800
70162 RAIN/WIND SENSOR FOR KNX RW SL SENSORS
15801 70164 Brightness/Wind sensor for KNX LW sl SENSORS

With logic gates (AND/OR). Configuration with ETS software. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Auxiliary voltage: 12…40 V DC (12…28 V AC). With installation instructions.
KNX W sl: Wind Sensor for KNX.

KNX R sl: Rain Sensor for KNX.

KNX RW sl: Rain/Wind Sensor for KNX.

KNX LW sl: Brightness/Wind Sensor for KNX.

15801
70164 BRIGHTNESS/WIND SENSOR FOR KNX LW SL SENSORS
15826 70358 KNX temperature sensor with display and two push buttons SENSORS

The KNX T-B-UP measures ambient temperature. The sensor can receive an external measured value via the bus and process it with the own data to an overall temperature (mixed value). The KNX T-B-UP offers two push buttons for changing the ambient temperature (target value).

The KNX T-B-UP provides three switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling.

The integrated display shows the own value and data received from the bus (e. g. date,time). The housing is completed with a frame of the switching series installed in the building and thus merges with the interior.

Functions and Operation:

  • Measurement of temperature
  • Display 1-3 rows (own values or values received from the bus)
  • 2 push buttons for changing the ambient temperature at the device.
    The step size can be adjusted from 0,1°C to 5°C.
  • Mixed value from own measured value and external value (proportions can be set in percentage)
  • PI controller for heating (one or two step) and cooling (one or two step)
  • 3 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
  • 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
  • Configuration is accomplished by means of the KNX software ETS
15826
70358 KNX TEMPERATURE SENSOR WITH DISPLAY AND TWO PUSH BUTTONS SENSORS
16718 70321 Heating Actuator for KNX, 8 outputs. CLIMATE CONTROL

The KNX K actuators have got internal temperature controllers and output channels for controlling heating or cooling systems. The temperature controllers can control both the outputs on the KNX K and other climate control system on the KNX Bus.

In automatic mode, the temperature controllers are set at nominal temperatures for different modes. This way, it is easy to switch between the modes, comfort, standby, eco and building protection. The switch is made via an object e. g. via a manual switch, time switch or sensor switch outputs in the KNX-System.

The buttons on the device allow for direct manual switching of the connected systems. LEDs show whether the output channel was manually operated or is running in an automatic mode.

16718
70321 HEATING ACTUATOR FOR KNX, 8 OUTPUTS. CLIMATE CONTROL
16728 70391 KNX Door or Gate Control Module with 3 Outputs and 2 Binary Inputs ACTUATORS - OUTPUTS

 The Door operator control module KNX A3-B2 has three outputs for door control and two binary inputs.

Functions:

• 3 outputs for door operation (impulse or dead-man mode)
• 2 binary inputs for the bus functions switches, toggle switches, blinds, shutters, marquees, windows, dimmers, 8 but encoders, temperature encoders, brightness encoder, scenes

16728
70391 KNX DOOR OR GATE CONTROL MODULE WITH 3 OUTPUTS AND 2 BINARY INPUTS ACTUATORS - OUTPUTS
17678 70179 KNX T-Objekt-UP Temperature Sensor SENSORS
The Temperature Sensor KNX T-Objekt-UP measures ambient temperature. The sensor can receive an external measured value via the bus and process it with the own data to an overall temperature (mixed value).
The KNX T-Objekt-UP provides three switching outputs with adjustable threshold values. The switching outputs and further communication objects can be linked via AND and OR logic gates. Additionally, an integrated actuating variable comparator can compare and output values that are received via communication objects. The sensor has got a PI controller for heating and cooling.
The device is completed with a frame and cover of the switching series installed in the building and thus merges with the interior.
17678
70179 KNX T-OBJEKT-UP TEMPERATURE SENSOR SENSORS
17679 70406 Salva KNX TH with temperature and humidity sensor SENSORS

Salva KNX

KNX Smoke Detector,temperature and air humidity

Salva KNX TH and Salva KNX basic are smoke detector sensors for the KNX building bus system. Their compact housing accommodates the sensors, evaluation circuits and bus-coupling electronics. The smoke alarm features an automatic evaluation sensor system for early and accurate fire alarms. Alarms are output as a local acoustic signal and a bus telegram. Salva KNX basic signals smoke alarm, Salva KNX-TH signals smoke and/or heat alarm.

AND logic gates and OR logic gates allow for a link between data and statuses. Multi-functional modules change input data as required by means of calculations, querying a condition, or converting the data point type.

The Salva KNX TH model additionally features integrated sensors for temperature and air humidity. The measured values can be used for the control of limit-dependent switching outputs. The devices have PI controls for heating/cooling (depending on temperature) and for ventilation (depending on humidity).

17679
70406 SALVA KNX TH WITH TEMPERATURE AND HUMIDITY SENSOR SENSORS
17688 70193 KNX WS1000 Style Building Contorl System VISUALIZATION

KNX WS1000 Style building controller invitation to tender

 

Control panel for KNX with integrated controller functions. Colour touch display (8.4 inches) for operation and automatic function setting. Default setting via ETS.

Indoor automatic functions for shading (sun/eye protection) and window exhaust air extraction for 22 channels/façades. Lighting control and time functions. KNX connection for data transfer.

Also 32 wireless channels (Elsner RF wireless for optional exhaust air extraction units, motor control units, sensors, remote control). Direct connection of a weather station possible (P04i-GPS).

Operating voltage: 230V AC Central unit dimensions 270 x 185 x 9 (W x H x installation depth in mm), surface or cavity wall mounting, dimensions of surface mounting box 254 x 171 x 85 (W x H x D in mm). Colour white/grey.

 

Manufactured by: Elsner Elektronik (www.elsner-elektronik.de)

Type: KNX WS1000 Style

17688
70193 KNX WS1000 STYLE BUILDING CONTORL SYSTEM VISUALIZATION
17690 70197 KNX Touch One Style - Touch Panel for Room Automation VISUALIZATION
  • Internal automatic shade controls (sun protection / privacy)
  • Room temperature control (heating, cooling, ventilation)
  •  Internal lighting control Integrated interior sensors (temperature, humidity)
  •  Bus functions for time and scene control Universal menu for displaying and operating the function and assignments of objects
  •  Functions of bus: comparator of variables of accionamiento, logic And / Or The configuration realizes using the software ETS KNX

The Room Controller KNX Touch One Style enables control of the KNX building technology for one room by means of a touch-sensitive display screen. The unit provides integrated control functions which can also be directly set on the display (automatic). Basic settings are made by the installer in the ETS.
The KNX Touch One Style with integrated indoor sensor (temperature, air humidity) includes an internal automated operation function for shades (sun/privacy shades) and room climate control (heating, cooling, ventilation), internal light control as well as bus functions for time and scene control. 4 binary inputs enable the connection of conventional buttons, switches and window contacts.
Eight universal pages with up to eight functions per page can be created to ensure the orderly operation and display of the function and object assignments.
The Remo 8 eight-channel wireless remote control can be learned by means of the KNX Touch One Style for remote control of the drives.

17690
70197 KNX TOUCH ONE STYLE - TOUCH PANEL FOR ROOM AUTOMATION VISUALIZATION
17691 70190 KNX Interface for WS1000 Color/Style SIN FAMILIA
The KNX Interface for WS1000 allows for communication between the WS1000 Color or WS1000 Style Control System and the KNX bus system. On the one hand, data of the control unit can be sent to the KNX bus (e. g. weather data). On the other hand, the WS1000 can control drives in the KNX system directly and use sensor data from the KNX system.
17691
70190 KNX INTERFACE FOR WS1000 COLOR/STYLE SIN FAMILIA
17692 70249 KNX B8-TH KNX interface, 8 binary and 2 sensor inputs INPUTS
The  Interface KNX B8-TH: has eight binary inputs and two additional sensor inputs
for temperature or temperature and air humidity. They are used to integrate signals
and values from conventional buttons and sensors into the KNX building bus.
The application software of the Interface KNX B8-TH:
contains both switch outputs for temperature and humidity as well as PI
controllers for heating/cooling and ventilation. The binary inputs can be configured as switches,
up/down buttons, dimmers or encoders in various configurations.
Due to its compact design, the interface fits into a switch box. The binary contacts are
connected using the cables supplied with the delivery.
17692
70249 KNX B8-TH KNX INTERFACE, 8 BINARY AND 2 SENSOR INPUTS INPUTS
17693 70143 KNX PS640 USB: without bus functions. With USB interface. SYSTEM DEVICES

The power supplies deliver a 29 V bus voltage for the KNX system and 24 V DC supply voltage for 24 V devices. Output current max. 640 mA. With display and key pad. Reset on the device possible. Installation on DIN rail.
KNX PS640: without bus functions.
KNX PS640+: with bus functions (transfer of malfunction messages/operating, time/period reset via the bus).
KNX PS640 USB: without bus functions. With USB interface.
KNX PS640+USB: with bus functions (transfer of malfunction messages/operating data, time/period reset via the bus) and USB interface.
KNX PS640-IP: without bus functions. With Ethernet interface (RJ45 connector). Allows for routing (Ethernet as fast backbone for KNX data), use as line coupler, tunneling (bus access over IP).
KNX PS640+IP: with bus functions (transfer of malfunction messages/operating data, time/period reset via the bus) and Ethernet interface (RJ45 connector). Allows for routing (Ethernet as fast backbone for KNX data), use as line coupler, tunneling (bus access over IP).

17693
70143 KNX PS640 USB: WITHOUT BUS FUNCTIONS. WITH USB INTERFACE. SYSTEM DEVICES
17694 60121 WS1000 Color Building Control System 4 drive outputs 230 V VISUALIZATION
Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow
17694
60121 WS1000 COLOR BUILDING CONTROL SYSTEM 4 DRIVE OUTPUTS 230 V VISUALIZATION
17695 60122 WS1000 Color Building Control System 6 drive outputs 230 V VISUALIZATION

Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

17695
60122 WS1000 COLOR BUILDING CONTROL SYSTEM 6 DRIVE OUTPUTS 230 V VISUALIZATION
17696 60123 WS1000 Color Building Control System 8 drive outputs 230 V VISUALIZATION

Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

17696
60123 WS1000 COLOR BUILDING CONTROL SYSTEM 8 DRIVE OUTPUTS 230 V VISUALIZATION
17698 60125 WS1000 Color Building Control System 4 drive outputs 230 V VISUALIZATION

Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

17698
60125 WS1000 COLOR BUILDING CONTROL SYSTEM 4 DRIVE OUTPUTS 230 V VISUALIZATION
17699 60126 WS1000 Color Building Control System 6 drive outputs 230 V SIN FAMILIA

Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

17699
60126 WS1000 COLOR BUILDING CONTROL SYSTEM 6 DRIVE OUTPUTS 230 V SIN FAMILIA
17700 60127 WS1000 Color Building Control System 8 drive outputs 230 V VISUALIZATION

Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

17700
60127 WS1000 COLOR BUILDING CONTROL SYSTEM 8 DRIVE OUTPUTS 230 V VISUALIZATION
17701 60128 WS1000 Color Building Control System 10 drive outputs 230 V SIN FAMILIA

Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

17701
60128 WS1000 COLOR BUILDING CONTROL SYSTEM 10 DRIVE OUTPUTS 230 V SIN FAMILIA
17704 60135 N° 60135 WS1 Color-1, white, for 1 drive 230 v Building Control Systems VISUALIZATION
Apart from shading and ventilation the WS1 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting. The WS1 Color includes the operating panel with integrated indoor sensor and the weather station. Further separate indoor sensors can be wirelessly integrated into the system and allow different climate zones to be created (individual room control).
The touch display makes operation of the WS1 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow
17704
60135 N° 60135 WS1 COLOR-1, WHITE, FOR 1 DRIVE 230 V BUILDING CONTROL SYSTEMS VISUALIZATION
17714 30520 T-UP Temperature Sensor for KNX B8-TH RF
Sensors for Interface KNX B8-TH. Installation in a socket, for common switch programs. Delivery
without frame.
T-UP: Temperature Sensor.
TH-UP: Temperature/humidity Sensor
17714
30520 T-UP TEMPERATURE SENSOR FOR KNX B8-TH RF
17718 30131 P04i distributor Weather data distributor for P04i CONTROLLERS

The P04i distributor operates four WS1, WS1000 Color or (KNX) WS1000 Style controls with a P04i-GPS weather station. The weather data is provided to all connected controls.
17718
30131 P04I DISTRIBUTOR WEATHER DATA DISTRIBUTOR FOR P04I CONTROLLERS
17719 30132 P04i -Data Collector SIN FAMILIA
Weather data collector comprising 5 data inputs (1 input for P04i-GPS, 4 inputs for P04i-W) and 1 data
output (for WS1 and WS1000). Operating voltage: 230 V AC. Installation on DIN rail
17719
30132 P04I -DATA COLLECTOR SIN FAMILIA
18207 70475 Display Corlo Touch KNX 5in WL with WiFI connectivity VISUALIZATION

https://www.youtube.com/watch?v=R24D4NydlLA&index=18&list=PLR0tfmkmhnBGWxpoi6PHvTUcyWOsmvcqM

The Display Corlo Touch KNX 5in for the KNX system offers a variety of options for its use: Its touch-sensitive glass interface means that it can be used as a normal switch. The high resolution display is ideal for displaying text, images or graphics. In addition to current readings and messages, the KNX bus system can also display photographs, for example. Concurrently, you can set up the Corlo Touch KNX 5in as a control center for automatic shading, ventilation and air conditioning regulation.

With the Corlo Touch KNX 5in WL model, you can also show network content on the display using the WLAN connection, e.g. web pages, IP camera images or visualizations. The Corlo Touch KNX 5in WL display screen can, for example, be shown on a Smartphone, if a VPN connection is provided externally.

Corlo Mobile App
for Corlo Touch KNX 5in WL is available in Google Play Store (Android) and in the App Store (Apple). Requirements: Corlo Touch KNX 5in WL. Terminal (smart phone, tablet PC) with Wi-Fi access and operating system Android 3.0 or iOS 8.0 (and up).

Housing : Glass: real glass, tempered
Housing: plastic
Display: Visible diagonal: 5 inches Resolution: 800 × 480 pixel
Viewing Angle: 12 o’clock viewing direction
Opening angle x: -70° to +70° typ.
Opening angle y: -60° to +60° typ.
Colours
• Black glass, edge glossy black
• Custom colours on request
Assembly: Flush mounting (Wall installation in junction box Ø 60 mm)


Dimensions
Housing overall approx. 133 × 97 × 35 (W × H × D, mm),
Mounting depth approx. 20 mm
Weight display unit Corlo Touch KNX 5in WL: approx. 210 g
Ambient temperature: Operation 0...+50°C, storage -10...+50°C
Ambient humidity: max. 95% RH, avoid condensation
Operating voltage: 24 V DC ±10%
Power consumption Corlo Touch KNX 5in
• approx. 2.7 W maximum (when ambient lighting 100% white, display brightness 100%)
• approx. 2.0 W in normal operation (when ambient lighting off, display brightness 50%)
• approx. 1.4 W in standby operation (when ambient lighting off, display off)
(was measured with 24 V auxiliary voltage)
Power consumption Corlo Touch KNX 5in WL
• approx. 3.5 W maximum (when ambient lighting 100% white, display brightness 100%)
• approx. 2.4 W in normal operation (when ambient lighting off, display brightness 50%)
• approx. 1.9 W in standby operation (when ambient lighting off, display off)
(was measured with 24 V auxiliary voltage)
Data output/ bus communication: KNX +/- Bus connector terminal
Communication objects: 1022
Other data interfaces: Micro SD
Inputs: 4× Analog/digital, max. cable length 10 m
Setting range of temperature sensor T-NTC at input of Corlo Touch: -40°C...+80°C

18207
70475 DISPLAY CORLO TOUCH KNX 5IN WL WITH WIFI CONNECTIVITY VISUALIZATION
18208 70481 Display Corlo Touch KNX 5in VISUALIZATION

https://www.youtube.com/watch?v=R24D4NydlLA&index=18&list=PLR0tfmkmhnBGWxpoi6PHvTUcyWOsmvcqM

The Display Corlo Touch KNX 5in for the KNX system offers a variety of options for its use: Its touch-sensitive glass interface means that it can be used as a normal switch. The high resolution display is ideal for displaying text, images or graphics. In addition to current readings and messages, the KNX bus system can also display photographs, for example. Concurrently, you can set up the Corlo Touch KNX 5in as a control center for automatic shading, ventilation and air conditioning regulation.

With the Corlo Touch KNX 5in WL model, you can also show network content on the display using the WLAN connection, e.g. web pages, IP camera images or visualizations. The Corlo Touch KNX 5in WL display screen can, for example, be shown on a Smartphone, if a VPN connection is provided externally.

Corlo Mobile App
for Corlo Touch KNX 5in WL is available in Google Play Store (Android) and in the App Store (Apple). Requirements: Corlo Touch KNX 5in WL. Terminal (smart phone, tablet PC) with Wi-Fi access and operating system Android 3.0 or iOS 8.0 (and up).

Housing : Glass: real glass, tempered
Housing: plastic
Display: Visible diagonal: 5 inches Resolution: 800 × 480 pixel
Viewing Angle: 12 o’clock viewing direction
Opening angle x: -70° to +70° typ.
Opening angle y: -60° to +60° typ.
Colours
• Black glass, edge glossy black
• Custom colours on request
Assembly: Flush mounting (Wall installation in junction box Ø 60 mm)


Dimensions
Housing overall approx. 133 × 97 × 35 (W × H × D, mm),
Mounting depth approx. 20 mm
Weight display unit Corlo Touch KNX 5in WL: approx. 210 g
Ambient temperature: Operation 0...+50°C, storage -10...+50°C
Ambient humidity: max. 95% RH, avoid condensation
Operating voltage: 24 V DC ±10%
Power consumption Corlo Touch KNX 5in
• approx. 2.7 W maximum (when ambient lighting 100% white, display brightness 100%)
• approx. 2.0 W in normal operation (when ambient lighting off, display brightness 50%)
• approx. 1.4 W in standby operation (when ambient lighting off, display off)
(was measured with 24 V auxiliary voltage)
Power consumption Corlo Touch KNX 5in WL
• approx. 3.5 W maximum (when ambient lighting 100% white, display brightness 100%)
• approx. 2.4 W in normal operation (when ambient lighting off, display brightness 50%)
• approx. 1.9 W in standby operation (when ambient lighting off, display off)
(was measured with 24 V auxiliary voltage)
Data output/ bus communication: KNX +/- Bus connector terminal
Communication objects: 1022
Other data interfaces: Micro SD
Inputs: 4× Analog/digital, max. cable length 10 m
Setting range of temperature sensor T-NTC at input of Corlo Touch: -40°C...+80°C

18208
70481 DISPLAY CORLO TOUCH KNX 5IN VISUALIZATION
18471 70701 KNX RF LC-TP Media Coupler for KNX TP / KNX RF SYSTEM DEVICES

The media coupler KNX RF LC-TP connects the wired KNX installation (KNX TP, twisted pair) with the KNX radio (KNX RF). The media coupler is used to forward messages from TP to RF and from RF to TP. The KNX RF LC-TP uses the KNX RF S standard.

 The KNX RF LC-TP uses multiple display pages to show the addressing, traffic and message flow. The housing is supplemented with a frame of the switch series used in buildings, and thus fits seamlessly into the interior fittings

18471
70701 KNX RF LC-TP MEDIA COUPLER FOR KNX TP / KNX RF SYSTEM DEVICES
18472 70711 KNX RF-MSG-ST Radio Actuator ACTUATORS - OUTPUTS

The KNX RF-MSG-ST is a radio actuator for KNX radio (KNX RF). The actuator controls one drive (blind, shutter, awning or window).

The KNX RF-MSG-ST uses the KNX RF S standard.

  • 1 connection for 230 V-drive (STAK3)
  • Reception of the control signal via radio KNX RF
  • Automatic runtime measurement of the drives for positioning (incl. fault reporting object)
  • Position feedback (movement position, also slat position for shutters)
  • Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)
  • Scene control for movement position with 16 scenes per drive (also slat position for shutters)
  • Blocking objects and alarm reports have different priorities, so safety functions always take precedence (e.g. wind block)
  • Manual or automatic priority setting via time or communication object
  • Brief time limit (movement command blocked) and 2 movement limits
  • Configuration is made using the KNX software ETS 5

 

18472
70711 KNX RF-MSG-ST RADIO ACTUATOR ACTUATORS - OUTPUTS
18473 70541 Shutter actuator. Outputs: 2 x Up/Down, free of potential, max. 30 V DC or 230 V AC ACTUATORS - OUTPUTS

The drives of blinds, awnings, roller shutters or windows are controlled with the actuator KNX S2 with integrated façade control. The connected drives can be directly operated via the push button pairs of the actuator.

Due to the potential-free design of the outputs, drives up to 30 V DC and up to 230 V AC can be controlled in exactly the same way as other systems (eg a hand-held input of a motor control unit).

The automatic for shading or window ventilation can be set externally or internally. Internally there are numerous options for blocking, locking (eg master-slave) and priority settings (eg manual-automatic). Scenes can be saved and recalled via the bus (scene control with 16 scenes per drive).

features:

• 2 potential-free outputs for shading or window drives

• Keypad with button pairs and status LEDs

• Position feedback (travel position, for Venetian blinds also slat position)

• Position memory (travel position) via a 1-bit object (storage and retrieval eg via pushbutton)

• Control by internal or external automatic control

• Integrated shading control for each drive output (with slat tracking after sun blinds for blinds)

• Integrated window ventilation control

• Scene control for driving position with 16 scenes per drive (blinds also with slat position)

• Mutual locking of two drives using zero position sensors prevents collisions, Eg from shading and window (master slave)

• Block objects and alarm messages have different priorities so that safety functions always take precedence (eg wind lock)

• Setting the priority of manual or automatic control over time or communication object

• 5 security objects for each channel

• Short-term restriction (driving command disabled) and 2 driving restriction

18473
70541 SHUTTER ACTUATOR. OUTPUTS: 2 X UP/DOWN, FREE OF POTENTIAL, MAX. 30 V DC OR 230 V AC ACTUATORS - OUTPUTS
18494 70540 SHUTTER ACTUATOR. Outputs: 4 x Up/Down, free of potential, max. 30 V DC or 230 V AC. ACTUATORS - OUTPUTS

With the Actuator KNX S4 with integrated facade control, the drives of shutters,

awnings, blinds or windows are controlled. The connected drives can be directly operated with the switch pairs of the actuator.

With the potential-free design of the outputs, drives of up to 30 VDC and 230 VAC can be controlled, as well as other systems (e.g. manual switch input of a motor control unit).

The automation for the shading or window ventilation is specified externally or internally.

Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definitions (e.g. manual-automatic). Scenes are saved and called up via the bus (scene control with 16 scenes per drive).

Functions:

• 4 potential-free outputs for drives of shading or windows.

• Switch panel with switch pairs and status LEDs

• Position feedback (movement position, also slat position for shutters)

• Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)

• Control via internal or external automation functions

• Integrated shade control for each drive output (with slat tracking according to sun position for shutters)

• Integrated window ventilation control

• Scene control for movement position with 16 scenes per drive (also slat position for shutters)

• Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)

• Blocking objects and alarm reports have different priorities, so that safety functions always take precedence (e.g. wind block)

• Manual or automatic control configuration per time or communication object

• 5 security objects for each channel

• Brief time limit (movement command blocked) and 2 movement limits

 

18494
70540 SHUTTER ACTUATOR. OUTPUTS: 4 X UP/DOWN, FREE OF POTENTIAL, MAX. 30 V DC OR 230 V AC. ACTUATORS - OUTPUTS
18495 70530 KNX S4-B10 230 V: 4 multifunctional outputs (8 devices), 10 binary inputs. ACTUATORS - OUTPUTS

Actuator for the KNX bus system. 4 multi-function outputs, each for 1 drive (Up/Down) or 2 switchable devices (On/Off). 10 binary inputs (actuator or bus keys). Drive runtime measurement (position feedback). Storage of movement positions, 16-channel scene memory.
External or internal setting of the automatic functions possible. Internal automatic functions with shading or window control, blocks, locks, priority stipulations, short time and movement restrictions.


Outputs: 4 x Up/Down (8 x On/Off), 230 V AC.
Inputs: 10 x binary, variable voltage 6...80 V DC and 6...240 V AC.
Operating Voltage 230 V AC.
567 communication objects.
Rail-mounted device (6 division units) with 4 key pairs and status LEDs. Dimensions 107 x 88 x 60 (W x H x D in mm)

Manufactured by: Elsner Elektronik (www.elsner-elektronik.de)
Type: KNX S4-B10 230 V

18495
70530 KNX S4-B10 230 V: 4 MULTIFUNCTIONAL OUTPUTS (8 DEVICES), 10 BINARY INPUTS. ACTUATORS - OUTPUTS
18496 70531 KNX S2-B6 230 V: 2 multifunctional outputs (4 devices), 6 binary inputs. ACTUATORS - OUTPUTS

The actuators KNX S4-B10, KNX S2-B6 and KNX S1-B2 230 V with integrated façade control have multi-function outputs, push button pairs and control LEDs. A drive with up / down control (blinds, awnings, roller shutters, windows) or two switchable units (on / off with light and ventilation) can be connected to each of the multifunctional outputs. The connected drives and devices can be operated directly on the actuator and via connected hand towels.

The automatic can be set externally or internally. Internally, numerous options are available for blocking, locking (eg master-slave) and priority settings (eg manual-automatic). Scenes can be saved and recalled via the bus (scene control with 16 scenes per drive).

Binary inputs can be used either for direct operation (eg hand-held buttons) or as bus buttons (or for alarms, for example). The desired behavior can be precisely defined by selecting the reaction times in standard, comfort or dead man mode.

18496
70531 KNX S2-B6 230 V: 2 MULTIFUNCTIONAL OUTPUTS (4 DEVICES), 6 BINARY INPUTS. ACTUATORS - OUTPUTS
18497 70532 KNX S1-B2 230 V, 1 multifunctional output, 2 binary inputs ACTUATORS - OUTPUTS

KNX S4-B10 KNX S2-B6 | KNX S1-B2 230 V

Actuators with multifunctional outputs and inputs

Successor for 70137, 70180, 70181

The actuators KNX S4-B10, KNX S2-B6 and KNX S1-B2 230 V with integrated façade control have multi-function outputs, push button pairs and control LEDs. A drive with up / down control (blinds, awnings, roller shutters, windows) or two switchable units (on / off with light and ventilation) can be connected to each of the multifunctional outputs. The connected drives and devices can be operated directly on the actuator and via connected hand towels.

The automatic can be set externally or internally. Internally, numerous options are available for blocking, locking (eg master-slave) and priority settings (eg manual-automatic). Scenes can be saved and recalled via the bus (scene control with 16 scenes per drive).

 Binary inputs can be used either for direct operation (eg hand-held buttons) or as bus buttons (or for alarms, for example). The desired behavior can be precisely defined by selecting the reaction times in standard, comfort or dead man mode.

18497
70532 KNX S1-B2 230 V, 1 MULTIFUNCTIONAL OUTPUT, 2 BINARY INPUTS ACTUATORS - OUTPUTS
18519 70199 IP KNX Interface. For Mobotix IP cameras. GATEWAYS

The IP KNX interface serves to transmit data between the Mobotix IP cameras and the KNX bus system. For this purpose, the KNX telegrams are converted into the Ethernet protocols and sent to the LAN in which the cameras are installed (and vice versa).

Features:

• Communication with 8 IP cameras with 8 input and 8 output objects each

• Transfer of the camera events to the KNX bus

• Controlling the camera via the KNX bus

• KNX Bus Terminal and Ethernet / IP Connection (POE)

• Suitable for IP cameras that meet the communication requirements as

described in the camera settings in the manual  Configuration is made using the KNX software ETS. The product file can be downloaded from the Elsner Elektronik website on www.elsner-elektronik.de in the “Service” menu.

 

18519
70199 IP KNX INTERFACE. FOR MOBOTIX IP CAMERAS. GATEWAYS
18579 70615 KNX TH-UP Touch white Combined Indoor Sensor TEMPERATURE AND AIR HUMIDITY SENSORS
Indoor sensor for temperature and air humidity (relative, absolute). Calculation of dew point.
5 threshold values, logic gates (AND/OR), comparator for actuating variables. Calculation of
mixed values (own/external value). PI controllers for heating/cooling (temperature) and ventila-
tion (dehumidifi cation/humidifi cation). Confi guration with ETS. Operating voltage: bus voltage.
Available in white or black. For installation in a socket with 2 spring clips in a support ring. Combination
with switch systems with frame size 55 mm. Frame not included. With installation instructions 4 .
KNX TH-UP Touch: with display and touch buttons (usable as bus push buttons, for changing target
temperature or mode).
KNX TH-UP gl: without display, without push buttons.
18579
70615 KNX TH-UP TOUCH WHITE COMBINED INDOOR SENSOR TEMPERATURE AND AIR HUMIDITY SENSORS
18580 70616 KNX TH-UP Touch black Combined Indoor Sensor. TEMPERATURE AND AIR HUMIDITY SENSORS
Indoor sensor for temperature and air humidity (relative, absolute). Calculation of dew point.
5 threshold values, logic gates (AND/OR), comparator for actuating variables. Calculation of
mixed values (own/external value). PI controllers for heating/cooling (temperature) and ventila-
tion (dehumidifi cation/humidifi cation). Confi guration with ETS. Operating voltage: bus voltage.
Available in white or black. For installation in a socket with 2 spring clips in a support ring. Combination
with switch systems with frame size 55 mm. Frame not included. With installation instructions 4 .
KNX TH-UP Touch: with display and touch buttons (usable as bus push buttons, for changing target
temperature or mode).
KNX TH-UP gl: without display, without push buttons.
18580
70616 KNX TH-UP TOUCH BLACK COMBINED INDOOR SENSOR. TEMPERATURE AND AIR HUMIDITY SENSORS
18581 70621 KNX TH-UP gl: without display, without push buttons. Indoor sensor for temperature and air humidity SENSORS

KNX TH-UP gl: without display, without push buttons

Indoor sensor for temperature and air humidity (relative, absolute). Calculation of dew point.
5 threshold values, logic gates (AND/OR), comparator for actuating variables. Calculation of
mixed values (own/external value). PI controllers for heating/cooling (temperature) and ventila-
tion (dehumidifi cation/humidifi cation). Confi guration with ETS. Operating voltage: bus voltage.
Available in white or black. For installation in a socket with 2 spring clips in a support ring. Combination
with switch systems with frame size 55 mm. Frame not included. With installation instructions 4 .
KNX TH-UP Touch: with display and touch buttons (usable as bus push buttons, for changing target
temperature or mode).
KNX TH-UP gl: without display, without push buttons

18581
70621 KNX TH-UP GL: WITHOUT DISPLAY, WITHOUT PUSH BUTTONS. INDOOR SENSOR FOR TEMPERATURE AND AIR HUMIDITY SENSORS
18582 70622 KNX TH-UP gl: without display, without push buttons. Indoor sensor for temperature and air humidity SENSORS

KNX TH-UP gl: without display, without push buttons

Indoor sensor for temperature and air humidity (relative, absolute). Calculation of dew point.
5 threshold values, logic gates (AND/OR), comparator for actuating variables. Calculation of
mixed values (own/external value). PI controllers for heating/cooling (temperature) and ventila-
tion (dehumidifi cation/humidifi cation). Confi guration with ETS. Operating voltage: bus voltage.
Available in white or black. For installation in a socket with 2 spring clips in a support ring. Combination
with switch systems with frame size 55 mm. Frame not included. With installation instructions 4 .
KNX TH-UP Touch: with display and touch buttons (usable as bus push buttons, for changing target
temperature or mode).
KNX TH-UP gl: without display, without push buttons

18582
70622 KNX TH-UP GL: WITHOUT DISPLAY, WITHOUT PUSH BUTTONS. INDOOR SENSOR FOR TEMPERATURE AND AIR HUMIDITY SENSORS
18583 70618 KNX AQS/TH-UP Touch Combined Indoor Sensor: CO2, Temp., Humidity SENSORS

KNX AQS/TH-UP Touch
Combined Indoor Sensor: CO2, Temp., Humidity

Indoor sensor for CO ² concentration, temperature and air humidity (relative, absolute). Calculation of
dew point. 9 threshold values, logic gates (AND/OR), comparator for actuating variables. Calculation
of mixed values (own/external value). PI controllers for heating/cooling (temperature) and ventilati-
on (CO ² , dehumidifi cation/humidifi cation). Confi guration with ETS. Operating voltage: bus voltage.
Available in white or black. For installation in a socket with 2 spring clips in a support ring. Combination
with switch systems with frame size 55 mm. Frame not included. With installation instructions 4 .
KNX AQS/TH-UP Touch: with display and touch buttons (usable as bus push buttons, for changing
target temperature or mode).
KNX AQS/TH-UP gl: without display, without push buttons.

18583
70618 KNX AQS/TH-UP TOUCH COMBINED INDOOR SENSOR: CO2, TEMP., HUMIDITY SENSORS
18584 70619 KNX AQS/TH-UP Touch Combined Indoor Sensor: CO2, Temp., Humidity SENSORS

KNX AQS/TH-UP Touch
Combined Indoor Sensor: CO2, Temp., Humidity

Indoor sensor for CO ² concentration, temperature and air humidity (relative, absolute). Calculation of
dew point. 9 threshold values, logic gates (AND/OR), comparator for actuating variables. Calculation
of mixed values (own/external value). PI controllers for heating/cooling (temperature) and ventilati-
on (CO ² , dehumidifi cation/humidifi cation). Confi guration with ETS. Operating voltage: bus voltage.
Available in white or black. For installation in a socket with 2 spring clips in a support ring. Combination
with switch systems with frame size 55 mm. Frame not included. With installation instructions 4 .
KNX AQS/TH-UP Touch: with display and touch buttons (usable as bus push buttons, for changing
target temperature or mode).
KNX AQS/TH-UP gl: without display, without push buttons.

18584
70619 KNX AQS/TH-UP TOUCH COMBINED INDOOR SENSOR: CO2, TEMP., HUMIDITY SENSORS
18586 70625 KNX AQS/TH-UP Touch Combined Indoor Sensor: CO2, Temp., Humidity SENSORS

KNX AQS/TH-UP Touch
Combined Indoor Sensor: CO2, Temp., Humidity

Indoor sensor for CO ² concentration, temperature and air humidity (relative, absolute). Calculation of
dew point. 9 threshold values, logic gates (AND/OR), comparator for actuating variables. Calculation
of mixed values (own/external value). PI controllers for heating/cooling (temperature) and ventilati-
on (CO ² , dehumidifi cation/humidifi cation). Confi guration with ETS. Operating voltage: bus voltage.
Available in white or black. For installation in a socket with 2 spring clips in a support ring. Combination
with switch systems with frame size 55 mm. Frame not included. With installation instructions 4 .

KNX AQS/TH-UP gl: without display, without push buttons.

18586
70625 KNX AQS/TH-UP TOUCH COMBINED INDOOR SENSOR: CO2, TEMP., HUMIDITY SENSORS
18609 30165 Leak Leakage sensor for water / pipe break detection SENSORS
Detection of water at the probe. Acoustic alarm signal at the evaluation unit during water alarm and
follow-up time. Output for alarm signal (potential-free changeover contact). Operation voltage: 230 V
AC.
18609
30165 LEAK LEAKAGE SENSOR FOR WATER / PIPE BREAK DETECTION SENSORS
18836 70314 Leakage Sensor for Water/Pipe Break Detection SENSORS
The Leakage sensor Leak KNX includes an evaluation unit and a probe. If there is water between the electrodes of the probe, the evaluation unit produces an acoustic alarm. Additionally, the alarm signal is sent to the KNX bus.
18836
70314 LEAKAGE SENSOR FOR WATER/PIPE BREAK DETECTION SENSORS
18837 60549 Wireless dimmer for LED lighting strips RF

RF-L PWM-ST is a wireless dimmer for LED lighting strips. The LED strips are connected to the terminal box provided (4 terminals). The power supply is provided by a suitable power supply unit (the set includes a power supply unit for a maximum of 5 A in the scope of delivery).

A light connected to the Wireless Dimmer RF-L PWM-ST can also be operated directly using Elsner's remote control Remo 8 or Remo pro via the RF-B2-UP button interface or the solar radio button Corlo P RF. The wireless dimmer is also suitable for operation together with Elsner's WS1 and WS1000 Color and Style controllers and for the Solexa II wireless system. It is programmed to a wireless channel of the control system, receiving automatic and manual commands from it.

 

18837
60549 WIRELESS DIMMER FOR LED LIGHTING STRIPS RF
18896 70746 Remo KNX RF Radio Remote Control for KNX RF RF

The colour touchscreen of Remote control Remo KNX RF can be used to manually to control bus participants in the KNX system. Remo KNX RF uses the KNX RF S standard. The possible functions are

  • Switching
  • Dimming
  • Moving the drives of awnings, shutters, blinds or windows
  • Changing the temperature (for heating/cooling)
  • Calling and saving scenes.

The channels are set in the ETS. However, they can always be individually sorted and named on the display.

18896
70746 REMO KNX RF RADIO REMOTE CONTROL FOR KNX RF RF
19561 70613 Cala KNX AQS / TH 2.0 , with sensor for temperature, humidity and CO2 SENSORS

Room Controller Cala ® KNX



Touch Panel for Room Automation with KNX
• Up to 3 user interfaces for light (switching or dimming
with display of the current value*); Setting page for
RGB colour and temperature colour*
• Up to 3 user interfaces for shading or window with
display of current travel/slat position*
• PI controller for heating/cooling (temperature)
• User interfaces for up to 4 scenes*
• Measurement display; Display page for bus values
• With calculation of mixed values (own/external
value), threshold values
• Logic gates (AND/OR), multifunctional modules (for
calculation, conditions, transition), actuating variable
comparator, summer compensation for cooling
• Confi guration with ETS
• 4 inputs (binary inputs or for temperature sensor
T-NTC)
• Awailable in two colors: glass/body black or white
• Installation with 2 spring clips in a support ring
• Can be combined with switch systems with frame
size 55 mm, frame not included
• Operating voltage: bus voltage
• Delivery with installation instructions 2


• Cala KNX T:
• Temperature sensor
• Controller for heating/cooling


Cala KNX TH:
• Temperature sensor and humidity sensor
• Controller for heating/cooling and ventilation
(dehumidifi cation/humidifi cation)

19561
70613 CALA KNX AQS / TH 2.0 , WITH SENSOR FOR TEMPERATURE, HUMIDITY AND CO2 SENSORS
19566 70605 Cala KNX T 2.0 Ambient Climate Sensor and Control SENSORS

 

 

Room Controller Cala ® KNX



Touch Panel for Room Automation with KNX
• Up to 3 user interfaces for light (switching or dimming
with display of the current value*); Setting page for
RGB colour and temperature colour*
• Up to 3 user interfaces for shading or window with
display of current travel/slat position*
• PI controller for heating/cooling (temperature)
• User interfaces for up to 4 scenes*
• Measurement display; Display page for bus values
• With calculation of mixed values (own/external
value), threshold values
• Logic gates (AND/OR), multifunctional modules (for
calculation, conditions, transition), actuating variable
comparator, summer compensation for cooling
• Confi guration with ETS
• 4 inputs (binary inputs or for temperature sensor
T-NTC)
• Awailable in two colors: glass/body black or white
• Installation with 2 spring clips in a support ring
• Can be combined with switch systems with frame
size 55 mm, frame not included
• Operating voltage: bus voltage
• Delivery with installation instructions 2


• Cala KNX T:
• Temperature sensor
• Controller for heating/cooling


Cala KNX TH:
• Temperature sensor and humidity sensor
• Controller for heating/cooling and ventilation
(dehumidifi cation/humidifi cation)


Cala KNX AQS/TH:
• Sensor for CO 2 , temperature and humidity
• Controller for heating/cooling and ventilation
(CO 2 , dehumidifi cation/humidifi cation)
* New functions from version 2.0

Delivery without frame

19566
70605 CALA KNX T 2.0 AMBIENT CLIMATE SENSOR AND CONTROL SENSORS
19579 70610 Cala KNX Ambient Climate Sensor and Control SENSORS

 

 

Room Controller Cala ® KNX



Touch Panel for Room Automation with KNX
• Up to 3 user interfaces for light (switching or dimming
with display of the current value*); Setting page for
RGB colour and temperature colour*
• Up to 3 user interfaces for shading or window with
display of current travel/slat position*
• PI controller for heating/cooling (temperature)
• User interfaces for up to 4 scenes*
• Measurement display; Display page for bus values
• With calculation of mixed values (own/external
value), threshold values
• Logic gates (AND/OR), multifunctional modules (for
calculation, conditions, transition), actuating variable
comparator, summer compensation for cooling
• Confi guration with ETS
• 4 inputs (binary inputs or for temperature sensor
T-NTC)
• Awailable in two colors: glass/body black or white
• Installation with 2 spring clips in a support ring
• Can be combined with switch systems with frame
size 55 mm, frame not included
• Operating voltage: bus voltage
• Delivery with installation instructions 2


• Cala KNX T:
• Temperature sensor
• Controller for heating/cooling


Cala KNX TH:
• Temperature sensor and humidity sensor
• Controller for heating/cooling and ventilation
(dehumidifi cation/humidifi cation)


Cala KNX AQS/TH:
• Sensor for CO 2 , temperature and humidity
• Controller for heating/cooling and ventilation
(CO 2 , dehumidifi cation/humidifi cation)
* New functions from version 2.0

Delivery without frame

19579
70610 CALA KNX AMBIENT CLIMATE SENSOR AND CONTROL SENSORS
19580 70614 Cala KNX AQS / TH 2.0 , with sensor for temperature, humidity and CO2 SENSORS

Room Controller Cala ® KNX



Touch Panel for Room Automation with KNX
• Up to 3 user interfaces for light (switching or dimming
with display of the current value*); Setting page for
RGB colour and temperature colour*
• Up to 3 user interfaces for shading or window with
display of current travel/slat position*
• PI controller for heating/cooling (temperature)
• User interfaces for up to 4 scenes*
• Measurement display; Display page for bus values
• With calculation of mixed values (own/external
value), threshold values
• Logic gates (AND/OR), multifunctional modules (for
calculation, conditions, transition), actuating variable
comparator, summer compensation for cooling
• Confi guration with ETS
• 4 inputs (binary inputs or for temperature sensor
T-NTC)
• Awailable in two colors: glass/body black or white
• Installation with 2 spring clips in a support ring
• Can be combined with switch systems with frame
size 55 mm, frame not included
• Operating voltage: bus voltage
• Delivery with installation instructions 2


• Cala KNX T:
• Temperature sensor
• Controller for heating/cooling


Cala KNX TH:
• Temperature sensor and humidity sensor
• Controller for heating/cooling and ventilation
(dehumidifi cation/humidifi cation)

19580
70614 CALA KNX AQS / TH 2.0 , WITH SENSOR FOR TEMPERATURE, HUMIDITY AND CO2 SENSORS
19581 70611 Cala KNX TH, room controller with temperature and humidity sensor SENSORS

The Sensor with Cala KNX display for the KNX bus system measures various ambient climate. Via the bus, the indoor sensor can receive external values and process them further with its own data to a total value (mixed value, e.g. room average). All measured values can be used for the control of threshold value-dependent switching outputs. States can be linked via AND logic gates and OR logic gates. Multi-functional modules change input data as required by means of calculations, querying a condition, or converting the data point type. In addition, an integrated manipulated variable comparator can compare and output variables that were received via communication objects.

Integrated PI-controllers control ventilation (according to humidity or CO2-concentration) and/or heating/cooling (according to temperature), depending on the respective model.

Cala KNX features a touch display that shows various display and control pages depending on the individual configuration. There is one page available that shows the current measured values, a menu area to adjust device settings and pages with touch control elements for internal temperature control, for light (manual switching or dimming), for shades or windows (manual operation).

Cala KNX is supplemented with a frame of the switch series used in buildings, and thus fits seamlessly into the interior fittings.

Models:

N° 70601 Cala KNX T, black with temperature sensor
N° 70602 Cala KNX TH, black with temperature and humidity sensor
N° 70603 Cala KNX AQS/TH, black with sensor for temperature, humidity and CO2

Delivery without frame

19581
70611 CALA KNX TH, ROOM CONTROLLER WITH TEMPERATURE AND HUMIDITY SENSOR SENSORS
19582 70612 Cala KNX TH, room controller with temperature and humidity sensor SENSORS

The Sensor with Cala KNX display for the KNX bus system measures various ambient climate. Via the bus, the indoor sensor can receive external values and process them further with its own data to a total value (mixed value, e.g. room average). All measured values can be used for the control of threshold value-dependent switching outputs. States can be linked via AND logic gates and OR logic gates. Multi-functional modules change input data as required by means of calculations, querying a condition, or converting the data point type. In addition, an integrated manipulated variable comparator can compare and output variables that were received via communication objects.

Integrated PI-controllers control ventilation (according to humidity or CO2-concentration) and/or heating/cooling (according to temperature), depending on the respective model.

Cala KNX features a touch display that shows various display and control pages depending on the individual configuration. There is one page available that shows the current measured values, a menu area to adjust device settings and pages with touch control elements for internal temperature control, for light (manual switching or dimming), for shades or windows (manual operation).

Cala KNX is supplemented with a frame of the switch series used in buildings, and thus fits seamlessly into the interior fittings.

Models:

N° 70601 Cala KNX T, black with temperature sensor
N° 70602 Cala KNX TH, black with temperature and humidity sensor
N° 70603 Cala KNX AQS/TH, black with sensor for temperature, humidity and CO2

Delivery without frame

19582
70612 CALA KNX TH, ROOM CONTROLLER WITH TEMPERATURE AND HUMIDITY SENSOR SENSORS
19743 70165 KNX R sl Precipitation sensor (rain sensor) SENSORS

KNX R sl

Precipitation sensor

The Precipitation Sensor KNX R sl for the KNX building bus system detects precipitation. One switching output, AND logic gates and OR logic gates are available.

The compact housing of the KNX R sl accommodates the sensors, evaluation circuits and bus-coupling electronics.

19743
70165 KNX R SL PRECIPITATION SENSOR (RAIN SENSOR) SENSORS
19824 70632 KNX T-UP gl Temperature Sensor SENSORS
The Sensor KNX T-UP gl measures the room temperature. The indoor sensor can
receive an external measured value via the bus and process it with own data to an
overall temperature value (mixed value).
The KNX T-UP gl provides adjustable threshold values. The threshold value outputs and further communication objects can be linked by AND and OR logic gates.
Additionally, an integrated actuating variable comparator can compare and output
values that are received via communication objects. The sensor has integrated PI
controller for a heating/cooling system.
The device is completed with a frame of the switching series installed in the building
and thus merges with the interior.
Functions:
• Measurement of temperature
• Mixed values from own measured value and external values (proportions
can be set in percentage)
• PI controller for heating (one or two step) and cooling (one or two step)
depending on temperature. Control according to separate target values or
basic target temperature
• Threshold values can be adjusted per parameter or via communication
objects: 3 × temperature
• 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident
as well as 16 logic inputs in the form of communication objects, may be used
as inputs for the logic gates. The output of each gate may optionally be
configured as 1 bit or 2 x 8 bits
• 2 actuating variable comparators for output of minimum, maximum or
average values. Each with 5 inputs (for values received via communication
objects)
19824
70632 KNX T-UP GL TEMPERATURE SENSOR SENSORS
19834 70670 Intra-Sewi KNX L-Pr Presence Detector with Brightness Sensor SENSORS

(replaces 70668 Intra-Sewi KNX Pr)

The Sensor Intra-Sewi KNX L-Pr for the KNX building bus system captures brightness and motion in rooms.

• Brightness measurement with brightness control
• Motion detection
• Threshold values can be adjusted per parameter or via communication objects
• 4 AND and 4 OR logic gates, each with 4 inputs. All switching events as well as 16 logic inputs (in the form of communications objects) can be used as inputs for the logic gates. The output of each gate can be configured optionally as 1-bit or 2 x 8-bit
• Configuration is made using the KNX software ETS

19834
70670 INTRA-SEWI KNX L-PR PRESENCE DETECTOR WITH BRIGHTNESS SENSOR SENSORS
19836 70680 Intra-Sewi KNX TH-L-Pr Presence, Brightness, Temperature and air humidity sensor SENSORS

(replaces 70662 Intra-Sewi KNX TH-Pr)

The Sensor Intra-Sewi KNX TH-L-Pr additionally measures the temperature and the air humidity and calculates the dew-point. Via the bus, the indoor sensor can receive external values of temperature and humidity and process them further with its own data to a total value (mixed value, e.g. room average). Integrated PI-controllers control ventilation (humidification/dehumidification according to humidity) and heating/cooling (according to temperature).

• Brightness measurement with brightness control
• Motion detection
• Threshold values can be adjusted per parameter or via communication objects
• 4 AND and 4 OR logic gates, each with 4 inputs. All switching events as well as 16 logic inputs (in the form of communications objects) can be used as inputs for the logic gates. The output of each gate can be configured optionally as 1-bit or 2 x 8-bit
• Configuration is made using the KNX software ETS
•Measuring the temperature and air humidity (relative, absolute), each with mixed value calculation. The share of internal measurement value and external value can be set as a percentage
• Bus message, whether the values for temperature and air humidity are within the comfort field (DIN 1946). Dew point calculation
• PI-controller for heating (one or two-stage) and cooling (one or two-stage) according to temperature. Regulation according to separate setpoints or basic setpoint temperature
• PI controller for humidity according to humidity: Ventilate/Air (one-stage) or Ventilate (one or two-stage)
• 2 actuation variable comparators to output minimum, maximum or average values. 5 inputs each for values received via communication objects

19836
70680 INTRA-SEWI KNX TH-L-PR PRESENCE, BRIGHTNESS, TEMPERATURE AND AIR HUMIDITY SENSOR SENSORS
19853 70660 Intra-Sewi KNX T Temperature Sensor SENSORS
19853
70660 INTRA-SEWI KNX T TEMPERATURE SENSOR SENSORS
19855 70661 Intra-Sewi KNX TH Sensor for Temperature/Humidity SENSORS

The sensor Intra-Sewi KNX TH for the KNX building bus system measures the ambient temperature. Intra-Sewi KNX TH additionally captures the air humidity and calculates the dew-point. Via the bus, the indoor sensor can receive external values of temperature or humidity and process them further with their own data to a total value (mixed value, e.g. room average).
All measurement values can be used for the control of limit-dependent switching outputs. States can be linked via AND logic gates and OR logic gates. In addition, an integrated actuating variable comparator can compare and output variables that were received via communication objects.
An integrated PI-controller controls a heating/cooling (according to temperature). Intra-Sewi KNX TH offers a second controller for ventilation (humidification/dehumidification according to humidity) and a warning can be output to the bus as soon as the comfort field, as per DIN 1946, is left.
19855
70661 INTRA-SEWI KNX TH SENSOR FOR TEMPERATURE/HUMIDITY SENSORS
19859 70628 KNX T-UP Touch Temperature Sensor with Touch Buttons SENSORS

KNX T-UP Touch

Temperature Sensor with Touch Buttons

The Temperature Sensor KNX T-UP Touch measures the room temperature. The indoor sensor can receive an external measured value via the bus and process it with own data to overall temperature value (mixed value).
The KNX T-UP Touch offers two push buttons that may be used for changing the ambient temperature (target value), for switching between operating modes or as free programmable bus push buttons.
The KNX T-UP Touch provides adjustable threshold values. The threshold value outputs and further communication objects can be linked by AND and OR logic gates.
Additionally, an integrated actuating variable comparator can compare and output values that are received via communication objects. The sensor has integrated PI controller for a heating/cooling system.
The integrated display shows the own values and data received from the bus (e.g. date, time). The device is completed with a frame of of the switching series installed in the building and thus merges with the interior.

  • Measurement of temperature
  • Mixed value from own measured values and external values (proportions can be set in percentage)
  • Display 1-3 rows (own values or values received from the bus) or display of temperature control
  • 2 push buttons. Configuration as bus push button or for changing ambient temperature and switching between operating modes
  • PI controller for heating (one or two step) and cooling (one or two step) depending on temperature. Control according to separate target values or basic target temperature
  • Threshold values can be adjusted per parameter or via communication objects: 3 × temperature
  • 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 16 logic inputs in the form of communication objects, may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
  • 2 actuating variable comparators for output of minimum, maximum or average values. Each with 5 inputs (for values received via communication objects)
  • Configuration is made using the KNX software ETS 5

Models:

N° 70628 KNX T-UP Touch, jet black RAL 9005
N° 70629 KNX T-UP Touch, pure white RAL 9010

Delivery without frame

19859
70628 KNX T-UP TOUCH TEMPERATURE SENSOR WITH TOUCH BUTTONS SENSORS
19865 70517 S1E-UP 230 V shader actuator Electronic output for a 230 V-drive (no imputs) ACTUATORS - OUTPUTS

KNX Actuator for Shading Element or Window with 1 Channel for a 230 V Drive (Electronical Output), with Internal Automatic Functions

The 230 V AC motor of a blind, awning, a roller shutter or window is controlled with the KNX S1E 230 V actuators with integrated façade control. The electronic output switches silently. The automatic for the drive control can be specified externally or internally. There are numerous options for blocking, locking (eg master-slave) and priority settings (eg manual-automatic). Scenes can be stored and recalled via the bus (scene control with 16 scenes per drive). The KNX S1E-B4-UP and KNX S1E-B2-UP models have inputs that are used as bus inputs (push buttons, alarm messages, etc.) or for temperature sensors T-NTC. The KNX S1E-UP has no analog / digital inputs.

  • Electronic output for a 230 V-drive (shade, window)
  • Inputs for binary contact or temperature sensor (not on KNX S1E-UP)
  • Automatic runtime measurement of the drives for positioning (incl. fault reporting object)
  • Position feedback (movement position, also slat position for shutters)
  • Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)
  • Parameters for taking drive and mechanics downtimes into account
  • Control via internal or external automation functions
  • Integrated shade control with slat tracking according to sun position for shutters
  • Scene control for movement position with 16 scenes per drive (also slat position for shutters)
  • Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)
  • Blocking objects and alarm reports have different priorities, so safety functions always take precedence (e.g. wind block)
  • Manual or automatic priority setting via time or communication object
  • 4 temperature switching outputs in the application program with adjustable threshold values (presetting the parameters or communication object)
  • 4 AND and 4 OR logic gates each with 4 inputs. 16 logic inputs (in the form of communication objects) are available as inputs for the logic gates. The output from each gate can be configured optionally as 1-bit or 2 x 8-bit
  • Configuration is made using the KNX software ETS
19865
70517 S1E-UP 230 V SHADER ACTUATOR ELECTRONIC OUTPUT FOR A 230 V-DRIVE (NO IMPUTS) ACTUATORS - OUTPUTS
19866 70518 KNX S1E-BA2-UP 230 V, 2 A/D Inputs, shader actuator Electronic output for a 230 V-drive ACTUATORS - OUTPUTS

KNX Actuator for Shading Element or Window with 1 Channel for a 230 V Drive (Electronical Output), with Internal Automatic Functions

The 230 V AC motor of a blind, awning, a roller shutter or window is controlled with the KNX S1E 230 V actuators with integrated façade control. The electronic output switches silently. The automatic for the drive control can be specified externally or internally. There are numerous options for blocking, locking (eg master-slave) and priority settings (eg manual-automatic). Scenes can be stored and recalled via the bus (scene control with 16 scenes per drive). The KNX S1E-B4-UP and KNX S1E-B2-UP models have inputs that are used as bus inputs (push buttons, alarm messages, etc.) or for temperature sensors T-NTC. The KNX S1E-UP has no analog / digital inputs.

  • Electronic output for a 230 V-drive (shade, window)
  • Inputs for binary contact or temperature sensor (not on KNX S1E-UP)
  • Automatic runtime measurement of the drives for positioning (incl. fault reporting object)
  • Position feedback (movement position, also slat position for shutters)
  • Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)
  • Parameters for taking drive and mechanics downtimes into account
  • Control via internal or external automation functions
  • Integrated shade control with slat tracking according to sun position for shutters
  • Scene control for movement position with 16 scenes per drive (also slat position for shutters)
  • Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)
  • Blocking objects and alarm reports have different priorities, so safety functions always take precedence (e.g. wind block)
  • Manual or automatic priority setting via time or communication object
  • 4 temperature switching outputs in the application program with adjustable threshold values (presetting the parameters or communication object)
  • 4 AND and 4 OR logic gates each with 4 inputs. 16 logic inputs (in the form of communication objects) are available as inputs for the logic gates. The output from each gate can be configured optionally as 1-bit or 2 x 8-bit
  • Configuration is made using the KNX software ETS
19866
70518 KNX S1E-BA2-UP 230 V, 2 A/D INPUTS, SHADER ACTUATOR ELECTRONIC OUTPUT FOR A 230 V-DRIVE ACTUATORS - OUTPUTS
19867 70519 KNX S1E-BA2-UP 230 V, 4 A/D Inputs, shader actuator Electronic output for a 230 V-drive ACTUATORS - OUTPUTS

KNX Actuator for Shading Element or Window with 1 Channel for a 230 V Drive (Electronical Output), with Internal Automatic Functions

The 230 V AC motor of a blind, awning, a roller shutter or window is controlled with the KNX S1E 230 V actuators with integrated façade control. The electronic output switches silently. The automatic for the drive control can be specified externally or internally. There are numerous options for blocking, locking (eg master-slave) and priority settings (eg manual-automatic). Scenes can be stored and recalled via the bus (scene control with 16 scenes per drive). The KNX S1E-B4-UP and KNX S1E-B2-UP models have inputs that are used as bus inputs (push buttons, alarm messages, etc.) or for temperature sensors T-NTC. The KNX S1E-UP has no analog / digital inputs.

  • Electronic output for a 230 V-drive (shade, window)
  • Inputs for binary contact or temperature sensor (not on KNX S1E-UP)
  • Automatic runtime measurement of the drives for positioning (incl. fault reporting object)
  • Position feedback (movement position, also slat position for shutters)
  • Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)
  • Parameters for taking drive and mechanics downtimes into account
  • Control via internal or external automation functions
  • Integrated shade control with slat tracking according to sun position for shutters
  • Scene control for movement position with 16 scenes per drive (also slat position for shutters)
  • Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)
  • Blocking objects and alarm reports have different priorities, so safety functions always take precedence (e.g. wind block)
  • Manual or automatic priority setting via time or communication object
  • 4 temperature switching outputs in the application program with adjustable threshold values (presetting the parameters or communication object)
  • 4 AND and 4 OR logic gates each with 4 inputs. 16 logic inputs (in the form of communication objects) are available as inputs for the logic gates. The output from each gate can be configured optionally as 1-bit or 2 x 8-bit
  • Configuration is made using the KNX software ETS
19867
70519 KNX S1E-BA2-UP 230 V, 4 A/D INPUTS, SHADER ACTUATOR ELECTRONIC OUTPUT FOR A 230 V-DRIVE ACTUATORS - OUTPUTS
19868 70516 KNX S1R-BA4-UP 24 V Actuator for 24 V DC Motor Load capacity: max. 5 A ACTUATORS - OUTPUTS

The Actuator KNX S1R-BA4-UP 24 V with integrated façade controller regulates the 12 or 24 V DC motor for a shutter, an awning, a blind or window. Because the output is designed to be potential-free, other systems can also be controlled, e.g. via the manual switch input on a motor control unit.

Automation is specified externally or internally. Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definitions (e.g. manual-automatic). Scenes are saved and called up via the bus (scene control with 16 scenes per drive).

The KNX S1R-B4-UP 24 V has four inputs that are used as binary inputs (switches, alarm messages etc.) or as analogue inputs for T-NTC temperature sensors

  • Potential-free output with polarity changer for a 12 V DC or 24 V DC drive (shade, window) Load capacity: max. 5 A
  • 4 inputs for binary contacts or temperature sensor
  •  Automatic runtime measurement of the drives for positioning (incl. fault reporting object)
  • Position feedback (movement position, also slat position for shutters)
  • Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)
  • Parameters for taking drive and mechanics downtimes into account
  • Control via internal or external automation functions
  • Integrated shade control with slat tracking according to sun position for shutters
  • Scene control for movement position with 16 scenes per drive (also slat position for shutters)
  • Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)
  • Blocking objects and alarm reports have different priorities, so safety functions always take precedence (e.g. wind block)
  • Manual or automatic priority setting via time or communication object
  • 4 temperature switching outputs in the application program with adjustable threshold values (presetting the parameters or communication object)
  • 4 AND and 4 OR logic gates each with 4 inputs. 16 logic inputs (in the form of communication objects) are available as inputs for the logic gates. The output from each gate can be configured optionally as 1-bit or 2 x 8-bit
  • Configuration is made using the KNX software ETS
19868
70516 KNX S1R-BA4-UP 24 V ACTUATOR FOR 24 V DC MOTOR LOAD CAPACITY: MAX. 5 A ACTUATORS - OUTPUTS
19870 70533 KNX S4-B12 24V Multifunctional Actuator 4 Drive Outputs, 12 Inputs ACTUATORS - OUTPUTS

KNX S4-B12 24 V (4.0)

KNX Actuator, 4 Drive Outputs, 12 Inputs

Replacement for N° 70138 KNX S4-B12 24V

The Actuator KNX S4-B12 24V with integrated facade control has 4 outputs for direct current drives (12...24V DC, Up/Down), 4 button pairs and control LEDs. The outputs are compatible with shutter, awning, blind or window drives. Connected drives can be operated directly at KNX S4-B12 24V and via a hand switch.

The automation can be specified externally or internally. Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definition (e.g. manual-automatic). Scenes can be saved and called up via the bus (scene control with 16 scenes per drive).

Twelve binary inputs can be used either for direct operation (e.g. hand switches) or as bus switches (or also for e.g. alarm notifications). The desired behaviour can be defined precisely through selection of the response times in Standard, Comfort or Deadman mode.

19870
70533 KNX S4-B12 24V MULTIFUNCTIONAL ACTUATOR 4 DRIVE OUTPUTS, 12 INPUTS ACTUATORS - OUTPUTS
19876 70712 KNX RF-MSG-DST Actuator for KNX Radio for 1 Drive, 230V out RF

KNX RF-MSG-DST

Actuator for KNX Radio for 1 Drive, 230V out

The KNX RF-MSG-DST is a radio actuator for KNX radio (KNX RF). The actuator controls one drive (blind, shutter, awning or window). Via an additional connector, another motor control unit is supplied with power (loop-through function).
The KNX RF-MSG-DST uses the KNX RF S standard.

• Actuators for KNX RF
• Motor run time variable by ETS parameters or active
current metering
• Position feedback and storage, scenes
• Retransmitter function
• Connector housing with STAK 3 connector and STAS3
plug
• Operating voltage: 230 V AC
• Confi guration with ETS, KNX RF S-Mode
• Delivery with installation instructions 2
KNX RF-MSG-DST:
• Actuator for 1 drive (230 V AC / 4 A max.)
• Mains output to supply additional motor control units
(loop-through function

19876
70712 KNX RF-MSG-DST ACTUATOR FOR KNX RADIO FOR 1 DRIVE, 230V OUT RF
19877 70713 KNX RF-MSG-DST Actuator for KNX Radio for 1 Drive, 230V out RF

KNX RF-MSG-DST

Actuator for KNX Radio for 1 Drive, 230V out

The KNX RF-MSG-DST is a radio actuator for KNX radio (KNX RF). The actuator controls one drive (blind, shutter, awning or window). Via an additional connector, another motor control unit is supplied with power (loop-through function).
The KNX RF-MSG-DST uses the KNX RF S standard.

• Actuators for KNX RF
• Motor run time variable by ETS parameters or active
current metering
• Position feedback and storage, scenes
• Retransmitter function
• Connector housing with STAK 3 connector and STAS3
plug
• Operating voltage: 230 V AC
• Confi guration with ETS, KNX RF S-Mode
• Delivery with installation instructions 2
KNX RF-MSG-DST:
• Actuator for 1 drive (230 V AC / 4 A max.)
• Mains output to supply additional motor control units
(loop-through function

19877
70713 KNX RF-MSG-DST ACTUATOR FOR KNX RADIO FOR 1 DRIVE, 230V OUT RF
19992 70626 KNX AQS/TH-UP Touch Combined Indoor Sensor: CO2, Temp., Humidity SENSORS

KNX AQS/TH-UP Touch
Combined Indoor Sensor: CO2, Temp., Humidity

Indoor sensor for CO ² concentration, temperature and air humidity (relative, absolute). Calculation of
dew point. 9 threshold values, logic gates (AND/OR), comparator for actuating variables. Calculation
of mixed values (own/external value). PI controllers for heating/cooling (temperature) and ventilati-
on (CO ² , dehumidifi cation/humidifi cation). Confi guration with ETS. Operating voltage: bus voltage.
Available in white or black. For installation in a socket with 2 spring clips in a support ring. Combination
with switch systems with frame size 55 mm. Frame not included. With installation instructions 4 .

KNX AQS/TH-UP gl: without display, without push buttons.

19992
70626 KNX AQS/TH-UP TOUCH COMBINED INDOOR SENSOR: CO2, TEMP., HUMIDITY SENSORS
8337 10110 Solexa Shading Control SENSORS
Solexa Shading Control Complete system for control of an awning (resp. a group of awnings) or blind (resp. a group of blinds). Meteorological station1 with connection for drive. Radio connection between meteorological station and control unit. Battery-operated control unit with integrated indoor temperature sensor
8337
10110 SOLEXA SHADING CONTROL SENSORS
10251 2034 4 motor connection clamps (for assembly on a top hat rail) SIN FAMILIA
The Group Control Relay WGGS-4-H can operate up to four drives as a group.
Connections are screwless, using cage clamp terminals.
10251
2034 4 MOTOR CONNECTION CLAMPS (FOR ASSEMBLY ON A TOP HAT RAIL) SIN FAMILIA
5601 305 Temperature SensorT-KYT82 SENSORS
T-KTY82 Temperature Sensor Sensor for indoor and outdoor applications. For use with Actuators KNX SB4T- UP or Intelligent Electronic Control Units IMSG.
5601
305 TEMPERATURE SENSORT-KYT82 SENSORS
6118 2016 RACDC-H AC/DC Relay ACTUATORS - OUTPUTS
For up to two 24 V DC motors. 24 V DC input (external power supply required),
24 V DC output. Control with 230 V (up/down/N/PE). For assembly on
a top hat rail
6118
2016 RACDC-H AC/DC RELAY ACTUATORS - OUTPUTS
8145 2019 WG-PF Potential-free Relay ACTUATORS - OUTPUTS
WG-PF Potential-free Relay Change-over contact for ``up`` and ``down``. Control with 230 V (up/down/N/ PE). For assembly in a junction box.
8145
2019 WG-PF POTENTIAL-FREE RELAY ACTUATORS - OUTPUTS
8146 30109 Hinge Arm Mountings for meteorological stations BIG SENSORS
Big for all meteorological stations/sensors of Elsner Elektronik. For wall/pole/beam mounting. 1 hinge, total length approx. 400 mm, powdercoated, color RAL 9016 (traffic white)
8146
30109 HINGE ARM MOUNTINGS FOR METEOROLOGICAL STATIONS BIG SENSORS
10039 60511 RF remote control for touch one display, white OTHER ACCESSORIES
For Touch Display KNX Touch One
10039
60511 RF REMOTE CONTROL FOR TOUCH ONE DISPLAY, WHITE OTHER ACCESSORIES
11875 SONDA SO250 Sonda para sensor KNX SO250 SENSORS
Sonda de 10 metros para el sensor de ultrasonidos con un área de detección de entre 12 y 250 cm., capaz de medir distancias o volúmenes en recipientes rectangulares, esféricos, cilíndricos (horizontales y verticales).
11875
SONDA SO250 SONDA PARA SENSOR KNX SO250 SENSORS
12308 70264 Frame Corlo 1-gang chrome-plated glossy VISUALIZATION

Frame Corlo 1-gang chrome-plated glossy

12308
70264 FRAME CORLO 1-GANG CHROME-PLATED GLOSSY VISUALIZATION
12310 70265 Frame Corlo 2-gang chrome-plated glossy VISUALIZATION
Frame Corlo 2-gang chrome-plated glossy
12310
70265 FRAME CORLO 2-GANG CHROME-PLATED GLOSSY VISUALIZATION
12312 70266 Frame Corlo 3-gangs chrome-plated glossy VISUALIZATION
Frame Corlo 3-gangs chrome-plated glossy
12312
70266 FRAME CORLO 3-GANGS CHROME-PLATED GLOSSY VISUALIZATION
12968 30517 temperature sensors T-100. Cable length approx. 3m SENSORS
Spare parts for temperature sensors KNX T-UN. Cable length approx. 3m
12968
30517 TEMPERATURE SENSORS T-100. CABLE LENGTH APPROX. 3M SENSORS
12969 30518 temperature sensors T-130. Cable length approx. 3m SENSORS
Spare parts for temperature sensors KNX T-UN. Cable length approx. 3m
12969
30518 TEMPERATURE SENSORS T-130. CABLE LENGTH APPROX. 3M SENSORS
12970 30516 Temperature sensors T-NTC. Cable length approx. 3m SENSORS

For use with Corlo Touch KNX-Display. For indoor and outdoor applications, with sensor sleeve. Cable length approx. 3m.

12970
30516 TEMPERATURE SENSORS T-NTC. CABLE LENGTH APPROX. 3M SENSORS
16149 30146 Modbus Weather Stations SENSORS
With 3 brightness sensors, wind sensor, heated precipitation sensor and outdoor temperature sensor.
For Modbus. Operating voltage: 12-40 V DC (12-28 V AC). Combined fi xture for wall/pole mounting.
P03/3-Modbus without reception of a time signal
16149
30146 MODBUS WEATHER STATIONS SENSORS
16659 203 Group Control Relay, Housing IP54 SIN FAMILIA
The WGGS-4 allows for operation of up to four drive mechanisms as a group. The relay with housing for surface mounting is installed in a not visible area (e.g. sub distributor, revision hatch).
16659
203 GROUP CONTROL RELAY, HOUSING IP54 SIN FAMILIA
16923 30119 Mounting Arms for Weather Stations, Flex S 1 ball joint SIN FAMILIA

For wall mounting. 1 ball joint (25°), total length approx. 64 mm. Powder-coated RAL 9003 (Signal

white). For P03/Solexa/Suntracer, P04/Suntracer sl and Vari models.

16923
30119 MOUNTING ARMS FOR WEATHER STATIONS, FLEX S 1 BALL JOINT SIN FAMILIA
17697 60124 WS1000 Color Building Control System 10 drive outputs 230 V VISUALIZATION

Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

17697
60124 WS1000 COLOR BUILDING CONTROL SYSTEM 10 DRIVE OUTPUTS 230 V VISUALIZATION
17702 60145 WS1 Color-0, white, radio 230 V Building Control Systems VISUALIZATION

 

Apart from shading and ventilation the WS1 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting. The WS1 Color includes the operating panel with integrated indoor sensor and the weather station. Further separate indoor sensors can be wirelessly integrated into the system and allow different climate zones to be created (individual room control).
The touch display makes operation of the WS1 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow.

 

 

17702
60145 WS1 COLOR-0, WHITE, RADIO 230 V BUILDING CONTROL SYSTEMS VISUALIZATION
17712 10144 selecta II display SIN FAMILIA

System for control of shadings (awnings, blinds, shutters), windows, lights, heaters at Elsner RF radio

actuators (16 radio outputs). Local operation and external temperature measurement with Elsner RF

operating devices/sensors (32 radio inputs). Display and weather station as set, additional displays

available.

Touch display with integrated room temperature sensor for combination with weather station. Housing

for surface mounting. Integrated battery, charging via USB cable (e. g. Nº 10155).

Weather station for temperature, precipitation, wind speed, brightness (1 sun sensor), with GPS recei-

ver. Connection for 230 V motor (integrated motor control unit). For combination with Solexa II displays

(up to 4 pieces). Combined fixture for wall/pole. Operating voltage: 230 V AC

17712
10144 SELECTA II DISPLAY SIN FAMILIA
17716 30136 P04i-GPS WEATHER STATION SIN FAMILIA
The P04i-GPS weather station for WS1 and WS1000 Color/Style measures temperature, wind speed and brightness. It recognises precipitation and receives the GPS signal for time and location (international time signal and position).
17716
30136 P04I-GPS WEATHER STATION SIN FAMILIA
17717 30137 P04i-W Wind Sensor Windsensor SIN FAMILIA
Wind sensor for WS1 and WS1000 Color/Style and KNX WS1000 Style, in conjunction with P04i Data
Collector. Operating voltage: 24 V DC. Combined fixture for wall/pole mounting
17717
30137 P04I-W WIND SENSOR WINDSENSOR SIN FAMILIA
17720 30238 Connecting cable Corlo Touch – Push Buttons SIN FAMILIA
Pre-assembled for easy connection of Corlo M1-T push buttons or Corlo M2-T push buttons to Display
Corlo Touch KNX (WL)
17720
30238 CONNECTING CABLE CORLO TOUCH – PUSH BUTTONS SIN FAMILIA
18240 70152 SO250-UI Modbus Tank Senso SENSORS
The SO250-UI ultrasonic probe is used for recording the amount of liquid filling in tanks and for measuring distances. Apart from areas of use such as storm water tanks or heating oil tanks, fish ponds, wells or the truck parking distance can also be monitored.
The distance / fill level can be read directly on the display. The tank geometry and the relay switching outputs (modbus interface, current output, voltage output and two relay switching outputs) can be configured via the integrated keypad. When switching the relay, an acoustic alarm signal can be output.
18240
70152 SO250-UI MODBUS TANK SENSO SENSORS
19726 KNX RF-MSG-ST Radio Motor Control Unit, 1 drive RF

 

KNX RF-MSG-ST

Actuator for KNX Radio for 1 Drive

The KNX RF-MSG-ST is a radio actuator for KNX radio (KNX RF). The actuator controls one drive (blind, shutter, awning or window).

The KNX RF-MSG-ST uses the KNX RF S standard. With retransmitter function (from version 1.1).

19726
KNX RF-MSG-ST RADIO MOTOR CONTROL UNIT, 1 DRIVE RF
19862 30513 SONDA DE TEMPERATURA T-NTC-ST para KNX B8-TH CLIMATE CONTROL
T-NTC-ST for KNX B8-TH
• Temperature feed probe for indoor and outdoor
applications
• Measuring range -35…+100°C
• Cable length approx. 3 m
19862
30513 SONDA DE TEMPERATURA T-NTC-ST PARA KNX B8-TH CLIMATE CONTROL
19864 70514 KNX S1R-B4 PF KNX Actuator with Potential-Free Output ACTUATORS - OUTPUTS

KNX S1-BA4

KNX Actuator, 1 Multifunctional OUT, 4 A/D Inputs

Replacement for N° 70204 KNX S1R-B4 PF

The Actuator KNX S1-BA4 with integrated façade control has a multifunctional output which can connect to either a drive with Up/Down control (blinds, awnings, shutters, windows) or two switchable devices (On/Off for light and ventilation). Because the output is designed to be free of potential, other systems can also be controlled, e.g. via the manual switch input on a motor control unit.

Automation can be specified externally or internally. Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definitions (e.g. manual-automatic). Scenes can be saved and called up via the bus (scene control with 16 scenes per drive).

The KNX S1-BA4 has four analogue/digital inputs that are used as bus inputs (buttons, alarm messages etc.) or for temperature sensors T-NTC.

19864
70514 KNX S1R-B4 PF KNX ACTUATOR WITH POTENTIAL-FREE OUTPUT ACTUATORS - OUTPUTS
19869 70515 KNX S1E-BA4-UP PS KNX Actuator, 1 drive OUT, 4 IN, 24 V DC ACTUATORS - OUTPUTS

Replacement for N° 70205 KNX S1E-B4-UP PS

The Actuator KNX S1E-BA4-UP PS with integrated façade controller regulates the 24 V DC motor for a shutter, an awning, a blind or window. The electronic output with polarity changer switches silently. An internal power supply transforms the 230 V AC mains voltage into 24 V DC to power the motor (500 mA maximum).

The automation for the drive control is specified externally or internally. Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definitions (e.g. manual-automatic). Scenes are saved and called up via the bus (scene control with 16 scenes per drive).

The KNX S1E-BA4-UP PS has four inputs that are used as binary inputs (switches, alarm messages etc.) or as analogue inputs for T-NTC temperature sensors.

19869
70515 KNX S1E-BA4-UP PS KNX ACTUATOR, 1 DRIVE OUT, 4 IN, 24 V DC ACTUATORS - OUTPUTS


KNX SPECIAL CATALOGUES
Different looks for KNX push buttons
Push buttons
Smart metering
MDT Catalog 2017
Iddero Verso Interactive Presentation

LEARN
Free webinars
uBrick Tutorials
VideoTutorials CBSE


PARTICIPATE
µBrick Trivia
KNX Tips & tricks
TEST
Free test of CBSE visualization

LATEST KNX NEWS
All news

LATEST KNX OFFERS
All offers
DOWNLOADS
KNX - All brands

FUTURASMUS KNX GROUP
Contact
Location
Futurasmus in the world
FOLLOW US
YouTube Channel
Facebook
LinkedIN
Google+
Twitter

KNX++ TRAINING CENTER
Futurasmus Zentrum

CERTIFIED KNX TEST LAB
Futurasmus KNX Lab
SPECIALIZED KNX WHOLESALER CERTIFIED KNX TRAINING CENTRE
Futurasmus KNX Group is a highly specialized and internationally active KNX Wholesaler, being our forte the excellent technical support we provide. You can visit our online catalogue in this website and, if you are a professional, ask for a non binding offer for your KNX projects. Should you be interested in buying KNX components, you are welcome to read our General Sales Conditions and contact our technicians and commercial agents per telephone, e-mail or online help. Since 2003 we have been a Certified Training Centre KNX++, which means that we are entitled to impart the KNX Basic Course as well as the KNX Advanced Course and KNX Tutor Course. We are manufacturer-independent and also offer other specialized and monographic KNX seminars. After teaching more than 1.500 KNX partners, our KNX Trainers have quite a large and positive expertise. Please, contact us for customized KNX training worldwide (groups of at least 8 people) at training@futurasmus-knxgroup.org
USE OF COOKIES
We use our own and third-party cookies, analyzing your browsing habits in out website, with the finality of ensuring the quality, security and improvement of the offered services through the same. In the case that the user does not explicitly state whether to accept the installation of cookies, but continues using our website, it will mean that he has consented expressly, informing him about the possibility to block or remove the installed cookies on his computer by configuring the appropriate settings of the browser. You can get more information on this subject reading our "Cookies Policy".