Order by:   Filter results: 
Web Code Reference Description Category Price
8137 70157 KNX PY Pyranometer FOR knx SENSORS
KNX PY Pyranometer for KNX/EIB
Measures the global radiation. With 4 limit values and logic gates (AND
and OR). Output of a mixed value from own and external value. Configuration
with ETS software. With combined fixture for wall/pole mounting, with
2 brackets for pole mounting. Delivery with installation instructions5
8137
70157 KNX PY PYRANOMETER FOR KNX SENSORS
5667 3095 Suntracer KNX basic 230 VAC SENSORS
Suntracer KNX basic Meteorological Station for KNX/EIB
With wind sensor, heated rain sensor (1.2 W), sun sensor and outdoor temperature
sensor. AND and OR logic gates. Configuration with ETS software.
With combined fixture for wall/pole mounting, with 2 brackets for
pole mounting.
Suitable 20 VAC power supply unit for 24 V DC (20 VAC) model: Nº 2018.
5667
3095 SUNTRACER KNX BASIC 230 VAC SENSORS
5688 3090 SUNTRACER GPS light KNX 230V CA Meteorological Station for KNX/EIB SENSORS
Meteorological Station for KNX/EIB
With wind sensor, heated rain sensor (1.2 W), sun sensor, outdoor temperature
sensor and DCF77 receiver. Calculation of the position of the sun.
Calendar and week time switch. AND and OR logic gates. Configuration
with ETS software. With combined fixture for wall/pole mounting, with 2
brackets for pole mounting.
Suitable 20 VAC power supply unit for 24 V DC (20 VAC) model: Nº 2018.
5688
3090 SUNTRACER GPS LIGHT KNX 230V CA METEOROLOGICAL STATION FOR KNX/EIB SENSORS
6034 70131 Actuators KNX S-B4T-UP: 4 binary inputs, 1 input for temperature sensor ( T-KTY82). ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows
Available for 24 V DC motors or 230 V motors (motor connection of the
230V models with microfuse T6,3 A). Configuration with ETS software. For
assembly in a flush mounted socket. Delivery with installation instructions5.
6034
70131 ACTUATORS KNX S-B4T-UP: 4 BINARY INPUTS, 1 INPUT FOR TEMPERATURE SENSOR ( T-KTY82). ACTUATORS - OUTPUTS
6035 70133 Actuators KNX S-B2-UP 230 VAC 2 BINARY ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows  Available for 24 V DC motors or 230 V motors (motor connection of the  230V models with microfuse T6,3 A). Configuration with ETS software. For assembly in a flush mounted socket. Delivery with installation instructions

6035
70133 ACTUATORS KNX S-B2-UP 230 VAC 2 BINARY ACTUATORS - OUTPUTS
6036 70135 Actuators KNX S-UP 230 VAC , without additional inputs ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows  Available for 24 V DC motors or 230 V motors (motor connection of the 230V models with microfuse T6,3 A). Configuration with ETS software. For  assembly in a flush mounted socket. Delivery with installation instructions5.
6036
70135 ACTUATORS KNX S-UP 230 VAC , WITHOUT ADDITIONAL INPUTS ACTUATORS - OUTPUTS
6037 70134 Actuators KNX S-UP 24 VDC ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows  Available for 24 V DC motors or 230 V motors (motor connection of the 230V models with microfuse T6,3 A). Configuration with ETS software. For  assembly in a flush mounted socket. Delivery with installation instructi
6037
70134 ACTUATORS KNX S-UP 24 VDC ACTUATORS - OUTPUTS
6038 70130 Actuators KNX S-B4T-UP 24V ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows
Available for 24 V DC motors or 230 V motors (motor connection of the
230V models with microfuse T6,3 A). Configuration with ETS software. For
assembly in a flush mounted socket. Delivery with installation instructions5.
6038
70130 ACTUATORS KNX S-B4T-UP 24V ACTUATORS - OUTPUTS
6039 70132 KNX/EIB Actuators KNX S-B2-UP 24V ACTUATORS - OUTPUTS
KNX S KNX/EIB Actuators for shading or windows
Available for 24 V DC motors or 230 V motors (motor connection of the
230V models with microfuse T6,3 A). Configuration with ETS software. For
assembly in a flush mounted socket. Delivery with installation instructions5
6039
70132 KNX/EIB ACTUATORS KNX S-B2-UP 24V ACTUATORS - OUTPUTS
6040 70122 KNX Meteorological Sensors KNX W 230 VAC SENSORS
With logic gates (AND and OR). Configuration with ETS software. With combined fixture for wall/pole mounting, with 2 brackets for pole mounting. Delivery with installation instructions
6040
70122 KNX METEOROLOGICAL SENSORS KNX W 230 VAC SENSORS
6041 70123 KNX Meteorological Sensors KNX W 24VDC SENSORS
KNX Meteorological Sensors With logic gates (AND and OR). Configuration with ETS software. With combined fixture for wall/pole mounting, with 2 brackets for pole mounting. Delivery with installation instructions5. Suitable 20 VAC power supply unit for 24 V DC (20 VAC) model: Nº 2018.
6041
70123 KNX METEOROLOGICAL SENSORS KNX W 24VDC SENSORS
6044 70126 KNX Meteorological Sensors RW 230VAC SENSORS
KNX Meteorological Sensors With logic gates (AND and OR). Configuration with ETS software. With combined fixture for wall/pole mounting, with 2 brackets for pole mounting. Delivery with installation instructions5. Suitable 20 VAC power supply unit for 24 V DC (20 VAC)
6044
70126 KNX METEOROLOGICAL SENSORS RW 230VAC SENSORS
6045 70127 KNX RW 24VDC Rain/Wind Sensor for KNX/EIB. SENSORS
KNX Meteorological Sensors With logic gates (AND and OR). Configuration with ETS software. With combined fixture for wall/pole mounting, with 2 brackets for pole mounting. Delivery with installation instructions5. Suitable 20 VAC power supply unit for 24 V DC (20 VAC
6045
70127 KNX RW 24VDC RAIN/WIND SENSOR FOR KNX/EIB. SENSORS
6046 70128 KNX LW 230VAC Light/Wind Sensor for KNX/EIB. SENSORS
KNX Meteorological Sensors With logic gates (AND and OR). Configuration with ETS software. With combined fixture for wall/pole mounting, with 2 brackets for pole mounting. Delivery with installation instructions5. Suitable 20 VAC power supply unit for 24 V DC (20 VAC)
6046
70128 KNX LW 230VAC LIGHT/WIND SENSOR FOR KNX/EIB. SENSORS
6047 70129 KNX Meteorological Sensors KNX LW 24VDC SENSORS
KNX Meteorological Sensors With logic gates (AND and OR). Configuration with ETS software. With combined fixture for wall/pole mounting, with 2 brackets for pole mounting. Delivery with installation instructions5. Suitable 20 VAC power supply unit for 24 V DC (20 VAC) model
6047
70129 KNX METEOROLOGICAL SENSORS KNX LW 24VDC SENSORS
6117 3096 Suntracer KNX basic 24 V DC (20 VAC) SENSORS
Meteorological Station for KNX/EIB With wind sensor, heated rain sensor (1.2 W), sun sensor and outdoor temperature sensor. AND and OR logic gates. Configuration with ETS software. With combined fixture for wall/pole mounting, with 2 brackets for pole mounting. Suitable 20 VAC power supply unit for 24 V DC (20 VAC) model: Nº 2018.
6117
3096 SUNTRACER KNX BASIC 24 V DC (20 VAC) SENSORS
6331 70140 KNX PS640 for bus voltage and 24 V DC, Reset by means of the key pad possible SYSTEM DEVICES
KNX PS640 Power Supply Systems for KNX/EIB  The power supplies deliver a 29 V bus voltage for the KNX/EIB system and  24 V DC supply voltage for 24 V devives. Output currant max. 640 mA. With  display and key pad. For assembly on a top hat rail.
6331
70140 KNX PS640 FOR BUS VOLTAGE AND 24 V DC, RESET BY MEANS OF THE KEY PAD POSSIBLE SYSTEM DEVICES
8071 70151 KNX SO250Tank Sensor for KNX/EIB SENSORS
KNX SO250Tank Sensor for KNX/EIB
For measurement of the capacity of liquids in tanks and for distance measurement.
KNX interface, 2 output relays. Configuration with ETS software.
Evaluation unit with display and key pad, assembly on top hat rail.
Cable length of measuring sensor 10 m. Delivery with installation instructions5
8071
70151 KNX SO250TANK SENSOR FOR KNX/EIB SENSORS
8136 70141 KNX PS640 Power Supply Systems SYSTEM DEVICES
KNX PS640 Power Supply Systems for KNX/EIB  The power supplies deliver a 29 V bus voltage for the KNX/EIB system and 24 V DC supply voltage for 24 V devives. Output currant max. 640 mA. With display and key pad. For assembly on a top hat rail.
KNX PS640 for bus voltage and 24 V DC, Reset by means of the key pad possible.
8136
70141 KNX PS640 POWER SUPPLY SYSTEMS SYSTEM DEVICES
8138 70121 KNX T-AP Temperature Sensor for KNX/EIB SENSORS
Sensor for indoor and outdoor applications. Output of an overall temperature (mixed value from own and external value). 4 limit values. PI controller for heating and cooling. Configuration with ETS software. For surface mounting. Delivery with installation instructions5
8138
70121 KNX T-AP TEMPERATURE SENSOR FOR KNX/EIB SENSORS
9032 3094 Suntracer KNX-GPS light Weather station for KNX with GPS receiver SENSORS
The Weather Station Suntracer KNX-GPS light measures temperature, wind speed and brightness. It perceives precipitation and receives the GPS signal for time and position. Furthermore, the exact position of the sun (azimuth and elevation) is calculated on the basis of location coordinates and time.

All data may be used for the control of switching outputs which depend on threshold values. The states may be linked by means of AND and OR logic gates.

The compact housing of Suntracer KNX-GPS light stores the sensor system, the evaluation electronics and the electronics of the bus connection.


Functions and Operation:

· Brightness and position of the sun: The current light intensity is measured by means of a sensor. At the same time, Suntracer KNX-GPS light calculates the position of the sun (azimuth and elevation) on the basis of time and location

· Wind measurement: The measurement of wind speed is accomplished electronically and thus noiseless and reliable even in case of hail, snow and minus temperature. Air swirls and up-draught in the radius of the weather station are collected, too

· Precipitation perception: The surface of the sensor is heated so that only drops and flakes are recognised as precipitation but not fog or dew. If it stops raining or snowing, the sensor dries quickly and the precipitation message ends

· Temperature measurement

· Week and calendar time switch: The weather station receives time and date from the integrated GPS receiver. The week time switch operates up to 4 different periods each day. With the calendar time switch, you may determine 3 additional periods where the time switch accomplishes up to 2 activations and deactivations each day. The Switching outputs can be used as communication objects. The switching times are set by parameter or via communication objects

· Switching outputs for all measured and calculated values (Threshold values can be set by parameter or via communication objects)

· 8 AND and 8 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits

· Configuration is accomplished by means of the KNX software ETS



9032
3094 SUNTRACER KNX-GPS LIGHT WEATHER STATION FOR KNX WITH GPS RECEIVER SENSORS
9360 70142 KNX PS640-IP Router / Power Supply System SYSTEM DEVICES
The Power Supply System KNX PS640-IP combines the central functions of a KNX bus line: Power supply with throttle, IP router and IP interface:
The Power Supply Unit of the KNX PS640-IP delivers a 29 V bus voltage for the KNX system and 24 V DC supply voltage for 24 V devices.
Special operating conditions such as short circuit, electrical surge, overcharge or excess temperature are recorded and may be read off on the display. The present power discharge is displayed as well. It is possible to reset the connected bus devices directly by means of the key pad.

The IP router of the KNX PS640-IP allows for forwarding of telegrams between different lines via a rapid LAN (IP) backbone. The KNX PS640-IP therfore also takes on the function of a line coupler.

In parallel, the KNX PS640-IP can be used as interface for accessing the bus access via IP. Like this, the KNX system can be configuered and supervised from any PC in the LAN (Tunnelling).
9360
70142 KNX PS640-IP ROUTER / POWER SUPPLY SYSTEM SYSTEM DEVICES
9404 3093 Suntracer KNX-GPS Weather Station SENSORS
The Weather Station Suntracer KNX-GPS measures temperature, wind speed and brightness. It perceives precipitation and receives the GPS signal for time and position. Furthermore, the exact position of the sun (azimuth and elevation) is calculated on the basis of location coordinates and time.

All data may be used for the control of switching outputs which depend on threshold values. The states may be linked by means of AND and OR logic gates.

The compact housing of Suntracer KNX-GPS stores the sensor system, the evaluation electronics and the electronics of the bus connection.

Functions and Operation:

· Brightness and position of the sun: The current light intensity is measured by means of a sensor. At the same time, Suntracer KNX-GPS calculates the position of the sun (azimuth and elevation) on the basis of time and location

· Shading control for up to 6 fronts with tracking of the slats and shadow edge

· Wind measurement: The measurement of wind speed is accomplished electronically and thus noiseless and reliable even in case of hail, snow and minus temperature. Air swirlsand up-draught in the radius of the weather station are collected, too

· Precipitation perception: The surface of the sensor is heated so that only drops and flakes are recognised as precipitation but not fog or dew. If it stops raining or snowing, the sensor dries quickly and the precipitation message ends

· Temperature measurement

· Week and calendar time switch: The weather station receives time and date from the integrated GPS receiver. The week time switch operates up to 4 different periods each day. With the calendar time switch, you may determine 3 additional periods where the time switch accomplishes up to 2 activations and deactivations each day. The Switching outputs can be used as communication objects. The switching times are set by parameter

· Switching outputs for all measured and calculated values (Threshold values can be set by parameter or via communication objects)

· 8 AND and 8 OR logic gates with each 4 inputs. Every switching incident as well as 16 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits

· Configuration is accomplished by means of the KNX software ETS
9404
3093 SUNTRACER KNX-GPS WEATHER STATION SENSORS
9506 70119 Brightness Sensor KNX L
Brightness Sensor | Light Sensor | Sun Sensor
SENSORS
The brightness sensor measures the intensity of illumination and transfers the value to the KNX system. Six switching outputs with adjustable threshold values as well as additional AND and OR logic gates are available.
The sensor system, the evaluation electronics and the electronics of the bus connection are mounted in a compact housing.

Functions and Operation:

Brightness measurement: The current light intensity is measured by a sensor

3 switching outputs for twilight (up to 1000 lux), 3 for daylight (1-99 klux), each with adjustable threshold values (Threshold values can be set by parameter or via communication objects)

8 AND and 8 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits

Configuration is accomplished by means of the KNX software ETS
9506
70119 BRIGHTNESS SENSOR KNX L
BRIGHTNESS SENSOR | LIGHT SENSOR | SUN SENSOR
SENSORS
9986 70184 KNX TH65-AP Thermo-Hygrometer SENSORS
The KNX TH65-AP for KNX measures temperature and air humidity in indoor or outdoor areas and may be used for the prescribed monitoring of store rooms, stables or green houses.

In passive houses, the thermo-hygrometer checks the inlet of the outer air in automatic ventilation systems or it controls the comfort field according to DIN 1946.

Besides the calculation of mixed values, adjustable switching outputs and logic gates, the KNX TH65-AP offers a PI control for heating, cooling and ventilation.

The device is mounted on-wall and connected to the KNX bus system.
9986
70184 KNX TH65-AP THERMO-HYGROMETER SENSORS
10042 70220 KNX T-UN temperature sensor, IP 68, -30…+130°C SENSORS
The Temperature Sensor KNX T-UN consists of evaluation electronics and measuring sensor. The sensor measures temperature in indoor and outdoor areas. The sensor can receive an external measured value via the bus and process it with the own data to an overall temperature (mixed value). The KNX T-UN provides four switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling.
Functions:
• Measurement of temperature
• Mixed value from own measured value and external value (proportions can be set in percentage)
• PI controller for heating (one or two step) and cooling (one or two step)
• 4 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
• 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
10042
70220 KNX T-UN TEMPERATURE SENSOR, IP 68, -30…+130°C SENSORS
10772 70224 Air Quality Sensor for KNX SENSORS

Measures the concentration of CO2 in the ambient air. 4 limit values, logic gates (AND/OR). Output of a mixed value from own and external value. PI controller for one- or two-stage ventilation. Configuration with ETS software.

Available in 4 colours: white glossy (similar to RAL 9016), aluminium matt, anthracite matt, stainless steel matt. For assembly in a socket. Delivery without frame. With installation instructions4.

KNX AQS-UP basic without display, without push buttons.

KNX AQS-B-UP with display and buttons.

10772
70224 AIR QUALITY SENSOR FOR KNX SENSORS
10776 70229 Air Quality Sensor for KNX, with display and buttons WHITE SENSORS

Measures the concentration of CO2 in the ambient air. 4 limit values, logic gates (AND/OR). Output of a mixed value from own and external value. PI controller for one- or two-stage ventilation. Configuration with ETS software. Available in 4 colours: white glossy (similar to RAL 9016), aluminium matt, anthracite matt, stainless steel matt. For assembly in a socket. Delivery without frame. With installation instructions4.

KNX AQS-UP basic without display, without push buttons.

KNX AQS-B-UP with display and buttons

10776
70229 AIR QUALITY SENSOR FOR KNX, WITH DISPLAY AND BUTTONS WHITE SENSORS
10780 70234 Indoor Sensor for KNX, TEMPERATURE, HUMIDITY, CO2, BASIC White SENSORS

Indoor sensor for CO2 concentration, temperature and air humidity (relative, absolute). Calculation of dewpoint. 11 limit values, logic gates (AND/OR), comparator for actuating variables. Output of mixed values from own and external values. PI controller for heating/cooling (temperature) and ventilation (CO2, humidity). Configuration with ETS software.

Available in 4 colours: white glossy (similar to RAL 9016), aluminium matt, anthracite matt, stainless steel matt. For assembly in a socket. Delivery without frame. With installation instructions.

KNX AQS/TH-UP basic without display, without push buttons.

KNX AQS/TH-B-UP with display and buttons.

10780
70234 INDOOR SENSOR FOR KNX, TEMPERATURE, HUMIDITY, CO2, BASIC WHITE SENSORS
10784 70239 Sensor for KNX, Temperature, Humidity (Relative, absolute), CO2 SENSORS

Indoor sensor for CO2 concentration, temperature and air humidity (relative, absolute). Calculation of dewpoint. 11 limit values, logic gates (AND/OR), comparator for actuating variables. Output of mixed values from own and external values. PI controller for heating/cooling (temperature) and ventilation (CO2, humidity). Configuration with ETS software.

Available in 4 colours: white glossy (similar to RAL 9016), aluminium matt, anthracite matt, stainless steel matt. For assembly in a socket. Delivery without frame. With installation instructions4.

KNX AQS/TH-UP basic without display, without push buttons.

KNX AQS/TH-B-UP with display and buttons.

10784
70239 SENSOR FOR KNX, TEMPERATURE, HUMIDITY (RELATIVE, ABSOLUTE), CO2 SENSORS
12314 70221 KNX T-UN temperature sensor, IP 43, -35…+100°C SENSORS
The Temperature Sensor KNX T-UN consists of evaluation electronics and measuring sensor. The sensor measures temperature in indoor and outdoor areas. The sensor can receive an external measured value via the bus and process it with the own data to an overall temperature (mixed value). The KNX T-UN provides four switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling.
Functions:
• Measurement of temperature
• Mixed value from own measured value and external value (proportions can be set in percentage)
• PI controller for heating (one or two step) and cooling (one or two step)
• 4 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
• 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
12314
70221 KNX T-UN TEMPERATURE SENSOR, IP 43, -35…+100°C SENSORS
15795 70154 Suntracer KNX SL Weather Station for KNX SENSORS
With wind sensor, heated precipitation sensor (1.2 W), brightness sensor, outdoor temperature sensor, air pressure sensor and GPS receiver. Calculation of the position of the sun. Calendar time switch, week time switch. Shading control for 8 fronts with tracking of the slats and shadow edge and with frost protection. Logic gates (AND/OR). 4 comparators. Configuration with ETS software. Auxiliary voltage: 12…40 V DC (12…28 V AC). With combined fixture for wall/pole mounting, incl. clip for pole mounting. With installation instructions.
15795
70154 SUNTRACER KNX SL WEATHER STATION FOR KNX SENSORS
15803 70382 Vari KNX 3L, 3 brightness sensors, rotated 90° each SENSORS
Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.
Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.
15803
70382 VARI KNX 3L, 3 BRIGHTNESS SENSORS, ROTATED 90° EACH SENSORS
15816 70383 Vari KNX 3L, 3 brightness sensors, rotated 90° each, temperature sensor, IP44 SENSORS

Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.


Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15816
70383 VARI KNX 3L, 3 BRIGHTNESS SENSORS, ROTATED 90° EACH, TEMPERATURE SENSOR, IP44 SENSORS
15817 70384 Vari KNX 3L, 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, IP44 SENSORS


Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15817
70384 VARI KNX 3L, 3 BRIGHTNESS SENSORS, ROTATED 90° EACH, TEMPERATURE SENSOR, HUMIDITY SENSOR, IP44 SENSORS
15818 70385 KNX Temperature sensor, IP44 SENSORS


Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15818
70385 KNX TEMPERATURE SENSOR, IP44 SENSORS
15819 70386 KNX Temperature sensor, humidity sensor, IP44 SENSORS

Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15819
70386 KNX TEMPERATURE SENSOR, HUMIDITY SENSOR, IP44 SENSORS
15820 70388 KNX temperature sensor, humidity sensor, air pressure sensor., IP44 SENSORS

Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15820
70388 KNX TEMPERATURE SENSOR, HUMIDITY SENSOR, AIR PRESSURE SENSOR., IP44 SENSORS
15821 70389 KNX 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor., IP44 SENSORS

Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

15821
70389 KNX 3 BRIGHTNESS SENSORS, ROTATED 90° EACH, TEMPERATURE SENSOR, HUMIDITY SENSOR, AIR PRESSURE SENSOR., IP44 SENSORS
15864 70387 KNX GPS receiver TIME TRANSMITTERS - SWITCHES

Output of UTC, local time, mounting position. Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

15864
70387 KNX GPS RECEIVER TIME TRANSMITTERS ...
16714 70390 KNX 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor., IP44 SENSORS

Sensors for outdoor and indoor application. With calculation of mixed values, switching outputs with limit values, comparators and logic gates (AND/OR). Configuration with ETS software. Operating voltage: bus voltage. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Delivery with installation instructions.

Vari KNX 3L: 3 brightness sensors, rotated 90° each.
Vari KNX 3L-T: 3 brightness sensors, rotated 90° each, temperature sensor.
Vari KNX 3L-TH: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor.
Vari KNX T: temperature sensor.
Vari KNX TH: temperature sensor, humidity sensor.
Vari KNX TH-D: temperature sensor, humidity sensor, air pressure sensor.
Vari KNX 3L-TH-D: 3 brightness sensors, rotated 90° each, temperature sensor, humidity sensor, air pressure sensor.

16714
70390 KNX 3 BRIGHTNESS SENSORS, ROTATED 90° EACH, TEMPERATURE SENSOR, HUMIDITY SENSOR, AIR PRESSURE SENSOR., IP44 SENSORS
17072 70392 Sewi KNX Temperature sensor SIN FAMILIA

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.
Sewi KNX T Temperature sensor

 

17072
70392 SEWI KNX TEMPERATURE SENSOR SIN FAMILIA
17073 70393 Sewi KNX Wall/Ceiling Sensors, Combined sensor for temperature and air humidity SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX TH Combined sensor for temperature and air humidity

17073
70393 SEWI KNX WALL/CEILING SENSORS, COMBINED SENSOR FOR TEMPERATURE AND AIR HUMIDITY SENSORS
17074 70394 Sewi KNX AQS CO2-Sensor SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX AQS CO² sensor

17074
70394 SEWI KNX AQS CO2-SENSOR SENSORS
17075 70395 Sewi KNX Wall/Ceiling Sensors, Brightness sensor SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX L Brightness sensor

17075
70395 SEWI KNX WALL/CEILING SENSORS, BRIGHTNESS SENSOR SENSORS
17076 70396 Sewi KNX Wall/Ceiling Sensors, Brightness sensor with presence detector SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX L-Pr Brightness sensor with presence detector

17076
70396 SEWI KNX WALL/CEILING SENSORS, BRIGHTNESS SENSOR WITH PRESENCE DETECTOR SENSORS
17077 70397 Sewi KNX Wall/Ceiling Sensors, Combined sensor for CO², temperature, humidity, and air pressure SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX AQS/TH-D Combined sensor for CO², temperature, humidity, and air pressure

17077
70397 SEWI KNX WALL/CEILING SENSORS, COMBINED SENSOR FOR CO², TEMPERATURE, HUMIDITY, AND AIR PRESSURE SENSORS
17079 70398 Sewi KNX Wall/Ceiling Sensors, Combined sensor for temperature, humidity, brightness and presence detection SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

Sewi KNX Wall/Ceiling Sensors, CCombined sensor for temperature, humidity, brightness and presence detection

 

17079
70398 SEWI KNX WALL/CEILING SENSORS, COMBINED SENSOR FOR TEMPERATURE, HUMIDITY, BRIGHTNESS AND PRESENCE DETECTION SENSORS
17080 70399 Sewi KNX Wall/Ceiling Sensors, Combined sensor for CO², temperature, humidity, air pressure, brightness, SENSORS

With calculation of mixed values, switching outputs with limit values and logic gates (AND/OR),
8 multifunctional modules (for calculation, conditions, transition). Configuration with ETS software.
Operating voltage: bus voltage. For wall/ceiling mounting. Delivery with installation instructions4.

 

Sewi KNX AQS/TH-D L-Pr Combined sensor for CO², temperature, humidity, air pressure, brightness,presence detection

 

 

17080
70399 SEWI KNX WALL/CEILING SENSORS, COMBINED SENSOR FOR CO², TEMPERATURE, HUMIDITY, AIR PRESSURE, BRIGHTNESS, SENSORS
17447 70405 SALVA KNX basic Smoke Detector ALARMS CENTRAL

Smoke alarm sensors with optical detection based on the scattered light principle, certified according to EN 14604:2005/AC:2008 and 1172-CPR-150013. Local acoustic alarm signal output (warning sound at least 85 dB) and transfer to KNX bus. Local alarm acknowledgement
Signalling of smoke alarm
Smoke chamber pollution measurement and pollution display according to UL directive 
Power supply via battery (9 V). Lack of battery capacity is signalled optically and acoustically for 30 days and transmitted to the bus
High operative safety due to elaborate automatic self-testing of the entire electronics and separate energy measurement
Faults signalled locally and via the bus
High deceptive alarm immunity due to powerful measuring chamber and consideration of temperature fluctuations (though no temperature smoke alarm) 
8 AND and 8 OR logic gates each with 4 inputs. All switching events as well as 16 logic inputs (in the form of communications objects) can be used as inputs for the logic gates. The output from each gate can be configured optionally as 1-bit or 2 x 8-bit
8 multi-function modules (computers) for changing the input data by calculations, by querying a condition or by converting the data point type
4 actuating variable comparators to output minimum, maximum or average values. 5 inputs each for values received via communication objects


Additional functions for Salva KNX TH:

Signalling of heat alarms 
Temperature sensor and air humidity sensor with mixed value calculation, dewpoint calculation, comfort field query (DIN 1946)
Threshold values for measured and calculated values, adjustable via parameters or communication objects
PI control for heating/cooling (depending on temperature)
PI controller for ventilation (depending on air humidity)

17447
70405 SALVA KNX BASIC SMOKE DETECTOR ALARMS CENTRAL
10037 70195 KNX Touch One - 5,7" Colour touch display VISUALIZATION
5,7" Colour touch display with advanced functions for the control of façades and HVAC. - Available with frame in aluminium/graphite or White/grey - Surface mounting - Light, dimmer, blind control, etc - Automatic functions for façade and HVAC control (ventilation, heating, air conditioning) customized by the final user. - Temperature and humidity measurement. - Time programming. - Scenes. - 4 free potential binary inputs (up to 50meter cable) - Integrated KNX bus coupler - Optionally, RF control remote with 8 channels: o Magnetic wall mounting. o Available in aluminium or white
10037
70195 KNX TOUCH ONE - 5,7" COLOUR TOUCH DISPLAY VISUALIZATION
16716 70202 Actuators multifunctional relay output, 2 analogue/digital inputs. max 4 A (resistive load) ACTUATORS - OUTPUTS

Actuators KNX S1R 230 V with integrated façade control have a multifunctional
output which can connect to either a drive with Up/Down control (blinds, awnings,
shutters, windows) or two switchable devices (On/Off for light and ventilation). Because the output is designed to be free of potential, other systems can also be con-
trolled, e.g. via the manual switch input on a motor control unit.
Automation can be specified externally or internally. Internally, there are numerous op-
tions available for blocking, locking (e.g. master-slave) and priority definitions (e.g.
manual-automatic). Scenes can be saved and called up via the bus (scene control with
16 scenes per drive).
The KNX S1R-B4-UP and KNX S1R-B2-UP models are equipped with inputs which
are used as bus inputs (buttons, alarms, etc.) or for T-NTC temperature sensors. The
KNX S1R-UP model does not have any analogue/digital inputs.
Functions:
• Free of potential multifunctional output for a 230 V drive (shading,
windows) or connection of two switchable devices (light, fan)
• Relays switch, with little wear, during the zero-voltage transition.
• Inputs for binary contact or temperature sensor (not on KNX S1R-UP)
• Automatic runtime measurement of the drives for positioning (incl. fault
reporting object)
• Position feedback (movement position, also slat position for shutters)
• Position storage (movement position) via 1-bit object (storage and call-up
e.g. via buttons)
• Parameters for taking drive and mechanics downtimes into account
• Control via internal or external automation functions
• Integrated shade control with slat adjustment for shutters based on the
position of the sun
• Scene control for movement position with 16 scenes per drive (also slat
position for shutters)
• Mutual locking of two drives using zero position sensors prevents collisions
e.g. of shade and window (master–slave)
• Blocking objects and alarm reports have different priorities, so safety functions
always take precedence (e.g. wind block)
• Manual or automatic priority setting via time or communication object
• 4 temperature switching outputs in the application program with
adjustable threshold values (presetting the parameters or communication
object)
• 4 AND and 4 OR logic gates, each with 4 inputs. 16 logic inputs (in the form
of communication objects) are available as inputs for the logic gates. The
output of each gate can be configured optionally as 1-bit or 2 x 8-bit
Configuration is made using the KNX software ETS. The product file can be down-
loaded from the Elsner Elektronik website on www.elsner-elektronik.de in the “Ser-
vice” menu

. Technical specification

The product is compliant with the provisions of EU guidelines.
Housing Plastic
Colour White
Assembly Flush-mounted (in connector socket Ø 60 mm, 60 mm
deep)
Protection category IP 20
Dimensions approx. 50 x 50 x 54 (W × H × D, mm)
Weight approx. 100 g
Ambient temperature Operation -20…+70°C, storage -30…+85°C
Ambient humidity 5...80% RH, non-condensing
Operating voltage KNX bus voltage
Current at the bus 10 mA
Output 1 × output, free of potential
with 2 connections for drive up/down or 2 devices
(power supply, PE/N/1/2).
Secured by a microfuse T4.0 A.
Can withstand a total of max. 4 A (resistive load),
switch-on current totally max. 4 A at = 20ms.
Minimum current for run-
time measurement
AC effektive 200 mA
Inputs KNX S1R-UP 230V: no inputs
KNX S1R-B2-UP 230V: 2× analogue/digital.
KNX S1R-B4-UP 230V: 4× analogue/digital.

16716
70202 ACTUATORS MULTIFUNCTIONAL RELAY OUTPUT, 2 ANALOGUE/DIGITAL INPUTS. MAX 4 A (RESISTIVE LOAD) ACTUATORS - OUTPUTS
16717 70320 Heating Actuator for KNX, 4 outputs. CLIMATE CONTROL

The KNX K actuators have got internal temperature controllers and output channels for controlling heating or cooling systems. The temperature controllers can control both the outputs on the KNX K and other climate control system on the KNX Bus.

In automatic mode, the temperature controllers are set at nominal temperatures for different modes. This way, it is easy to switch between the modes, comfort, standby, eco and building protection. The switch is made via an object e. g. via a manual switch, time switch or sensor switch outputs in the KNX-System.

The buttons on the device allow for direct manual switching of the connected systems. LEDs show whether the output channel was manually operated or is running in an automatic mode.

16717
70320 HEATING ACTUATOR FOR KNX, 4 OUTPUTS. CLIMATE CONTROL
11337 70244 KNX VOC-UP basic Mixed Gas SENSORS

The Mixed Gas Sensor KNX VOC-UP basic recognizes volatile organic compounds in the room air. The indoor sensor can receive an external VOC value via the bus and process it with the own data to an overall value (mixed value, e. g. room average).

The KNX VOC-UP basic provides four switching outputs with adjustable threshold values. The switching outputs and further communication objects can be linked by AND and OR logic gates. Additionally, an integrated actuating variable comparator can compare and output values that are received via communication objects.
An integrated PI controllers allows for control of ventilation depending on VOC concentration.

The housing is completed with a frame of the switching series installed in the building and thus merges with the interior.

Functions and Operation:

  • Measurement of VOC (volatile organic compounds) in the air. In this process, an air quality value in CO2 eqivalents is calculated via an algorithm from the sum signal of all componds included in the mixed gas.
  • Mixed value from own measured value and external value (proportions can be set in percentage)
  • PI controller for ventilation depending on VOC concentration: dehumidification/humidification (one step) or dehumidification (one or two step)
  • 4 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
  • 8 AND and 8 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
  • 2 actuating variable comparators for output of minimum, maximum or avarage values
  • Configuration is accomplished by means of the KNX software ETS
11337
70244 KNX VOC-UP BASIC MIXED GAS SENSORS
11514 70137 Multifunctional Actuator KNX 4 Output - 10 Input 230V ACTUATORS - OUTPUTS

The KNX S4-B10 230 V Actuator with integrated facade control has 4 multifunctional outputs, 4 pairs of buttons and monitoring LEDs. Each of the four multifunctional outputs can connect to either a drive with Up/Down control (blinds, awnings, shutters, windows) or two switchable devices (On/Off for light and ventilation). The connected drives and devices can be operated directly on KNX S4-B10 230 V and via hand switches.

The automation can be specified externally or internally. Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definition (e.g. manual-automatic). Scenes can be saved and called up via the bus (scene control with 16 scenes per drive).

Ten binary inputs can be used either for direct operation (e.g. hand switches) or as bus switches (or also for e.g. alarm notifications). The desired behaviour can be defined precisely through selection of the response times in Standard, Comfort or Deadman mode.

Functions and Operation:

  • 4 multifunctional outputs each for a 230 V drive (shade, window) or for connecting two switchable devices (light, fan)
  • Keypad with 4 button pairs and status LEDs
  • 10 binary inputs for use as hand switches or as bus switches with variable voltage (6...80 V DC, 6...240 V AC)
  • Automatic runtime measurement of the drives for positioning (including fault notification object)
  • Position feedback (movement position, also slat position for blinds)
  • Position storage (movement position) via 1-bit object (storage and call-up e.g. via button)
  • Control via internal or external automation
  • Integrated shade control for each drive output (with slat tracking according to sun position for blinds)
  • Scene control for movement position with 16 scenes per drive (also slat position for blinds)
  • Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)
  • Blocking objects and alarm notifications have different priorities, so safety functions always take precedence (e.g. wind block)
  • Manual or automatic priority setting via time or communication object
  • Configuration is accomplished by means of the KNX software ETS
11514
70137 MULTIFUNCTIONAL ACTUATOR KNX 4 OUTPUT - 10 INPUT 230V ACTUATORS - OUTPUTS
11515 70138 KNX S4-B12 24V Multifunctional Actuator ACTUATORS - OUTPUTS

4 outputs 24 V DC, each for 1 drive (up/down). Integrated shading control. 12 binary inputs, 4 pairs of push buttons and control LEDs. Modular device 6 width units. Operating voltage 24 V DC. Configuration with ETS software.Delivery with installation instructions

11515
70138 KNX S4-B12 24V MULTIFUNCTIONAL ACTUATOR ACTUATORS - OUTPUTS
11923 70310 KNX I4-ERD Evaluation Unit for Ground Sensors TH-ERD SENSORS

Evaluation unit KNX I4-ERD for monitoring of ground temperature/humidity. For up to 4

Ground Sensors TH-ERD. 2 threshold values for temperature/humidity per sensor. Installationon DIN rail. Operating voltage 230 V AC. Delivery with installation instructions4. Suitable

ground temperature/humidity sensor: TH-ERD (optional), cable length 10 m.

11923
70310 KNX I4-ERD EVALUATION UNIT FOR GROUND SENSORS TH-ERD SENSORS
11931 70144 KNX PS640+USB with bus functions SYSTEM DEVICES

The Power Supply Systems KNX PS640+ and KNX PS640+USB deliver a 29 V bus voltage for the KNX system and 24 V DC supply voltage for 24 V devices. The KNX PS640+USB has got an additional USB interface for easy bus access.

Special operating conditions such as short circuit, electrical surge, overcharge or excess temperature are recorded and may be read off on the display. The present power discharge is displayed as well. It is possible to reset the connected bus devices directly by means of the key pad.

In addition all functions can be realised via the bus, too, e. g. the transfer of malfunction messages and operating data and a time/period reset. Malfunction messages are stored by the KNX PS640+(USB).

Functions and Operation:

  • Delivers a 29 V KNX bus voltage (reduced), output current max. 640 mA, short-circuit proof
  • Delivers 24 V DC (not reduced), output current max. 150 mA
  • Reset of a line directly on the device
  • Record of operating hours, overload, external overvoltage, internal overvoltage, short circuit and excess temperature
  • Display of operating data bus voltage, bus current and temperature of the device
  • The display may be shown in German, English, Spanish or Dutch
  • Bus connection for data transfer (e. g. malfunction messages, operating data)
  • Possibility for reset and diagnostics via the bus
  • Only KNX PS640+USB: USB interface for bus access via PC

Technical Data:

HousingPlastic material
ColourWhite
MountingSnap-on fitting on mounting rails
Protection categoryIP 20
Dimensionsapprox. 123 x 89 x 61 (W x H x D, mm), 7 width units
Weightapprox. 370 g
Ambient temperatureOperation -5…+45 °C, storage -25…+70°C
Ambient air humiditymax. 95% RH, avoid bedewing
Operating voltage230 V AC , 50 Hz
Outputs• KNX bus voltage 29 Volt (reduced),
Output current max. 640 mA, short-circuit proof
• 24 V DC (not reduced), Output current max. 150 mA
• KNX data
Data outputKNX +/- bus terminal plug
Communication objects27

Scope of Delivery:

  • Rail-mounted device with display and keypad
  • Data sheet with installation instruction and description of parameter setting (German or English)
  • Product file VD2 (German, English, Spanish) as download
11931
70144 KNX PS640+USB WITH BUS FUNCTIONS SYSTEM DEVICES
12300 70258 Corlo Touch,Touch Display for KNX, 3,5", white, with crhome-plated glossy edge VISUALIZATION

Touch display usable as a switch, for the setting of automatic functions and display of information.

Touch sensitive surface 3.5 inches. RGB frame illumination. Integrated proximity sensor and brightness sensor. Internal automatic functions for control of shading, room conditioning (heating, cooling, ventilation), lighting. 4 inputs (binary inputs or for temperatures sensor T-PT, Nº 30515). Micro SD card slot. USB interface. Installation in a socket.

Operating voltage 12...40 V DC. Delivery with installation instructions4.

Available in white or black. Please order display with edge to match the frame (glossy/matt).

Corlo Touch KNX: KNX connection for data communication.

Corlo Touch KNX WL: KNX connection. Connector for W-LAN stick.

Frame Corlo: Available as 1-, 2- or 3-gang frame, glossy or matt chrome-plated.

12300
70258 CORLO TOUCH,TOUCH DISPLAY FOR KNX, 3,5", WHITE, WITH CRHOME-PLATED GLOSSY EDGE VISUALIZATION
12304 70252 Corlo Touch, Touch Display for KNX. 3,5". Integrierte Wi-Fi, white, with chrome-plated glossy edge VISUALIZATION

Touch display usable as a switch, for the setting of automatic functions and display of information.

Touch sensitive surface 3.5 inches. RGB frame illumination. Integrated proximity sensor and brightness sensor. Internal automatic functions for control of shading, room conditioning (heating, cooling, ventilation), lighting. 4 inputs (binary inputs or for temperatures sensor T-PT, Nº 30515). Micro SD card slot. USB interface. Installation in a socket. Operating voltage 12...40 V DC. Delivery with installation instructions4.

Available in white or black. Please order display with edge to match the frame (glossy/matt).

Corlo Touch KNX: KNX connection for data communication.

Corlo Touch KNX WL: KNX connection. Connector for W-LAN stick.

Frame Corlo: Available as 1-, 2- or 3-gang frame, glossy or matt chrome-plated.

12304
70252 CORLO TOUCH, TOUCH DISPLAY FOR KNX. 3,5". INTEGRIERTE WI-FI, WHITE, WITH CHROME-PLATED GLOSSY EDGE VISUALIZATION
12316 70153 Tank Sensors for KNX SO250 basic SENSORS

Functions and Operation:

  • Distance measurement
  • Level measurement (filling volume or height) in ball, cubical and cylindrical
    tanks. Several tanks of the same type set up as a bank
  • 5 switched outputs with variable thresholds (thresholds are set optionally by parameters or via communication objects)
  • Setting of bus functions by means of the KNX software ETS
12316
70153 TANK SENSORS FOR KNX SO250 BASIC SENSORS
12971 70222 KNX T6-UN-B4 temperature evaluation unit SENSORS

The KNX T6-UN-B4 temperature evaluation unit has six inputs for T-100 or T-130 temperature sensors and four analogue/digital inputs, which can for example be used for buttons or T-NTC temperature sensors. The temperature measurement values for all inputs can be processed with external measurement values to provide a combined value (total temperature, average temperature).

The KNX T6-UN-B4 provides six switched outputs with adjustable threshold values. Six PI controllers control the heating and cooling (one- or two-stage). Logic gates can be used to set up additional operations.

12971
70222 KNX T6-UN-B4 TEMPERATURE EVALUATION UNIT SENSORS
14642 70350 Temperature sensors for KNX SENSORS

Thermometer for indoor applications. 4 threshold values, logic gates (AND/OR). Output of a mixed value from own and external value. PI controller for heating/cooling. Configuration with ETS software. Operating voltage: bus voltage.

Available in 4 colours: white glossy (simital to RAL 9016), aluminium matt, antracite matt, stainless stell matt. For installation in a socket. Frame not included. With installation instructions.

 

14642
70350 TEMPERATURE SENSORS FOR KNX SENSORS
14646 70282 Single push buttons, with integrated Temperature Sensor PUSH BUTTONS

The Single switch Corlo M1-T and the Double switch Corlo M2-T are mechanical switches for the Corlo system. A sensor for measuring the room temperature is integrated into both switches.
The switch contacts and the temperature sensor output may be used for the conventional installation and, for example, relay controls and PLC. The temperature contact is also ideally suited for a connection to the Corlo Touch KNX display.

14646
70282 SINGLE PUSH BUTTONS, WITH INTEGRATED TEMPERATURE SENSOR PUSH BUTTONS
14652 70286 M2-T Double Push Button, with sensor temperatura, 2 fold PUSH BUTTONS

Single or double push button for  System Corlo. Glass surface in black or white, Please order push button with edge to match the frame (custom coloured edge/frame on request)

Corlo Push Button M-T with integrated temperature sensor T-NTC. Available as single push button Corlo M1-T and as double push button Corlo M2-T.

14652
70286 M2-T DOUBLE PUSH BUTTON, WITH SENSOR TEMPERATURA, 2 FOLD PUSH BUTTONS
14924 70145 KNX PS640+IP WITH BUS FUNCTIONS AND ETHERNET INTERFACE SIN FAMILIA

The power supplies deliver a 29 V bus voltage for the KNX system and 24 V DC supply voltage for 24 V devices. Output current max. 640 mA. With display and key pad. Reset on the device possible. Installation on DIN rail.

KNX PS640: without bus functions.
KNX PS640+: with bus functions (transfer of malfunction messages/operating, time/period reset via the bus).
KNX PS640 USB: without bus functions. With USB interface.
KNX PS640+USB: with bus functions (transfer of malfunction messages/operating data, time/period reset via the bus) and USB interface.
KNX PS640-IP: without bus functions. With Ethernet interface (RJ45 connector). Allows for routing (Ethernet as fast backbone for KNX data), use as line coupler, tunneling (bus access over IP).
KNX PS640+IP: with bus functions (transfer of malfunction messages/operating data, time/period reset via the bus) and Ethernet interface (RJ45 connector). Allows for routing (Ethernet as fast backbone for KNX data), use as line coupler, tunneling (bus access over IP).

14924
70145 KNX PS640+IP WITH BUS FUNCTIONS AND ETHERNET INTERFACE SIN FAMILIA
15796 70155 Suntracer KNX sl light Weather Station for KNX SENSORS
With wind sensor, heated precipitation sensor (1.2 W), brightness sensor, outdoor temperature sensor and GPS receiver. Calculation of the position of the sun. Calendar time switch, week time switch. Shading control for 5 fronts. Logic gates (AND/OR). 4 comparators. Configuration with ETS software. Auxiliary voltage: 12…40 V DC (12…28 V AC). With combined fixture for wall/pole mounting, incl. clip for pole mounting. With installation instruction
15796
70155 SUNTRACER KNX SL LIGHT WEATHER STATION FOR KNX SENSORS
15797 70156 SUNTRACER KNX sl basic Weather Station for KNX SENSORS
With wind sensor, heated precipitation sensor (1.2 W), 3 brightness sensors (rotated 90° each), outdoor temperature sensor. Logic gates (AND/OR). 4 comparators. Configuration with ETS software. Auxiliary voltage: 12…40 V DC (12…28 V AC). With combined fixture for wall/pole mounting, incl. clip for pole mounting. With installation instructions.
15797
70156 SUNTRACER KNX SL BASIC WEATHER STATION FOR KNX SENSORS
15798 70158 Wind sensor for KNX W sl SENSORS

With logic gates (AND/OR). Configuration with ETS software. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Auxiliary voltage: 12…40 V DC (12…28 V AC). With installation instructions.
KNX W sl: Wind Sensor for KNX.

KNX R sl: Rain Sensor for KNX.

KNX RW sl: Rain/Wind Sensor for KNX.

KNX LW sl: Brightness/Wind Sensor for KNX.

15798
70158 WIND SENSOR FOR KNX W SL SENSORS
15800 70162 Rain/wind sensor for KNX RW sl SENSORS
With logic gates (AND/OR). Configuration with ETS software. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Auxiliary voltage: 12…40 V DC (12…28 V AC). With installation instructions.
KNX W sl: Wind Sensor for KNX.KNX R sl: Rain Sensor for KNX.KNX RW sl: Rain/Wind Sensor for KNX.KNX LW
15800
70162 RAIN/WIND SENSOR FOR KNX RW SL SENSORS
15801 70164 Brightness/Wind sensor for KNX LW sl SENSORS

With logic gates (AND/OR). Configuration with ETS software. With combined fixture for wall/pole mounting, incl. clip for pole mounting. Auxiliary voltage: 12…40 V DC (12…28 V AC). With installation instructions.
KNX W sl: Wind Sensor for KNX.

KNX R sl: Rain Sensor for KNX.

KNX RW sl: Rain/Wind Sensor for KNX.

KNX LW sl: Brightness/Wind Sensor for KNX.

15801
70164 BRIGHTNESS/WIND SENSOR FOR KNX LW SL SENSORS
15822 70354 KNX T-UP Temperature Sensor for KNX/EIB SENSORS

The Temperature Sensor KNX T-UP measures ambient temperature. The sensor can receive an external measured value via the bus and process it with the own data to an overall temperature (mixed value).

The KNX T-UP provides three switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling.

The integrated display shows the own value and data received from the bus (e. g. date, time). The housing is completed with a frame of the switching series installed in the building and thus merges with the interior.

Measurement of temperature

  • Display 1-3 rows (own values or values received from the bus)
  • Mixed value from own measured value and external value (proportions can be set in percentage)
  • PI controller for heating (one or two step) and cooling (one or two step)
  • 3 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
  • 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
  • Configuration is accomplished by means of the KNX software ETS
  • 15822
    70354 KNX T-UP TEMPERATURE SENSOR FOR KNX/EIB SENSORS
    15826 70358 KNX temperature sensor with display and two push buttons SENSORS

    The KNX T-B-UP measures ambient temperature. The sensor can receive an external measured value via the bus and process it with the own data to an overall temperature (mixed value). The KNX T-B-UP offers two push buttons for changing the ambient temperature (target value).

    The KNX T-B-UP provides three switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling.

    The integrated display shows the own value and data received from the bus (e. g. date,time). The housing is completed with a frame of the switching series installed in the building and thus merges with the interior.

    Functions and Operation:

    • Measurement of temperature
    • Display 1-3 rows (own values or values received from the bus)
    • 2 push buttons for changing the ambient temperature at the device.
      The step size can be adjusted from 0,1°C to 5°C.
    • Mixed value from own measured value and external value (proportions can be set in percentage)
    • PI controller for heating (one or two step) and cooling (one or two step)
    • 3 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
    • 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
    • Configuration is accomplished by means of the KNX software ETS
    15826
    70358 KNX TEMPERATURE SENSOR WITH DISPLAY AND TWO PUSH BUTTONS SENSORS
    15831 70362 KNX TH-UP Temperature/Humidity SENSORS

    The Indoor Sensor KNX TH-UP measures temperature and humidity and calculates the dew point. The sensor can receive external measured values via the bus and process them with the own data to an overall temperature and overall air humidity (mixed values).

    The KNX TH-UP provides seven switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling (depending on temperature) and for ventilation (depending on air humidity) and it can emit a warning to the bus as soon as the area of optimum comfort (according to DIN 1946) is left.

    The integrated display shows the own values and data received from the bus (e. g. date, time). The housing is completed with a frame of the switching series installed in the building and thus merges with the interior.

    Functions and Operation:

    • Measurement of temperature and air humidity (relative, absolute), calculation of dew point
    • Display 1-3 rows (own values or values received from the bus)
    • Mixed values from own measured values and external values (proportions can be set in percentage)
    • PI controller for heating (one or two step) and cooling (one or two step) depending on temperature
    • PI controller for ventilation depending on humidity: Dehumidify/humidify (one step) or dehumidify (one or two step)
    • 7 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
    • 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
    • Configuration is accomplished by means of the KNX software ETS
       
    15831
    70362 KNX TH-UP TEMPERATURE/HUMIDITY SENSORS
    15835 70366 KNX TH-UP Temperature/Humidity, with display SENSORS

    The Indoor Sensor KNX TH-UP measures temperature and humidity and calculates the dew point. The sensor can receive external measured values via the bus and process them with the own data to an overall temperature and overall air humidity (mixed values).

    The KNX TH-UP provides seven switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling (depending on temperature) and for ventilation (depending on air humidity) and it can emit a warning to the bus as soon as the area of optimum comfort (according to DIN 1946) is left.

    The integrated display shows the own values and data received from the bus (e. g. date, time). The housing is completed with a frame of the switching series installed in the building and thus merges with the interior.

    Functions and Operation:

    • Measurement of temperature and air humidity (relative, absolute), calculation of dew point
    • Display 1-3 rows (own values or values received from the bus)
    • Mixed values from own measured values and external values (proportions can be set in percentage)
    • PI controller for heating (one or two step) and cooling (one or two step) depending on temperature
    • PI controller for ventilation depending on humidity: Dehumidify/humidify (one step) or dehumidify (one or two step)
    • 7 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
    • 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs (in the form of communication objects) may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
    • Configuration is accomplished by means of the KNX software ETS
    15835
    70366 KNX TH-UP TEMPERATURE/HUMIDITY, WITH DISPLAY SENSORS
    15839 70370 KNX TH-B-UP Temperature/Humidity, with display and button SENSORS

    The Indoor Sensor KNX TH-B-UP measures temperature and humidity and calculates the dew point. The sensor can receive external measured values via the bus and process them with the own data to an overall temperature and overall air humidity (mixed values). The KNX TH-B-UP offers two push buttons for changing the ambient temperature (target value).

    The KNX TH-B-UP provides seven switching outputs with adjustable threshold values as well as additional AND and OR logic gates. The sensor has got a PI controller for heating and cooling (depending on temperature) and for ventilation (depending on air humidity) and it can emit a warning to the bus as soon as the area of optimum comfort (according to DIN 1946) is left.

    The integrated display shows the own values and data received from the bus (e. g. date, time). The housing is completed with a frame of the switching series installed in the building and thus merges with the interior.

    Functions and Operation:

    • Measurement of temperature and air humidity (relative and absolute), calculation of dew point
    • Mixed values from own measured values and external values (proportions can be set in percentage)
    • Display 1-3 rows (own values or values received from the bus)
    • 2 push buttons for changing the ambient temperature at the device.
      The step size can be adjusted from 0,1°C to 5°C.
    • PI controller for heating (one or two step) and cooling (one or two step) depending on temperature
    • PI controller for ventilation depending on humidity: Dehumidify/humidify (one step) or dehumidify (one or two step)
    • 7 switching outputs with adjustable threshold values (Threshold values can be set by parameter or via communication objects)
    • 4 AND and 4 OR logic gates with each 4 inputs. Every switching incident as well as 8 logic inputs in the form of communication objects may be used as inputs for the logic gates. The output of each gate may optionally be configured as 1 bit or 2 x 8 bits
    • Configuration is accomplished by means of the KNX software ETS
    15839
    70370 KNX TH-B-UP TEMPERATURE/HUMIDITY, WITH DISPLAY AND BUTTON SENSORS
    16718 70321 Heating Actuator for KNX, 8 outputs. CLIMATE CONTROL

    The KNX K actuators have got internal temperature controllers and output channels for controlling heating or cooling systems. The temperature controllers can control both the outputs on the KNX K and other climate control system on the KNX Bus.

    In automatic mode, the temperature controllers are set at nominal temperatures for different modes. This way, it is easy to switch between the modes, comfort, standby, eco and building protection. The switch is made via an object e. g. via a manual switch, time switch or sensor switch outputs in the KNX-System.

    The buttons on the device allow for direct manual switching of the connected systems. LEDs show whether the output channel was manually operated or is running in an automatic mode.

    16718
    70321 HEATING ACTUATOR FOR KNX, 8 OUTPUTS. CLIMATE CONTROL
    16728 70391 KNX Door or Gate Control Module with 3 Outputs and 2 Binary Inputs ACTUATORS - OUTPUTS

     The Door operator control module KNX A3-B2 has three outputs for door control and two binary inputs.

    Functions:

    • 3 outputs for door operation (impulse or dead-man mode)
    • 2 binary inputs for the bus functions switches, toggle switches, blinds, shutters, marquees, windows, dimmers, 8 but encoders, temperature encoders, brightness encoder, scenes

    16728
    70391 KNX DOOR OR GATE CONTROL MODULE WITH 3 OUTPUTS AND 2 BINARY INPUTS ACTUATORS - OUTPUTS
    16734 70380 Multifunctional KNX Actuator, 1 MF output, 2 binary inputs SIN FAMILIA

    The KNX S-B 230 V Actuators with integrated facade control have got multifunctional outputs, pairs of buttons and monitoring LEDs. Each of the outputs can connect to either a drive with Up/Down control (blinds, awnings, shutters, windows) or two switchable devices (On/Off for light and ventilation). The connected drives and devices can be operated directly at the units and via hand switches.

    The automation can be specified externally or internally. Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definition (e.g. manual – automatic). Scenes can be saved and called up via the bus (scene control with 16 scenes per drive).

    The binary inputs can be used either for direct operation (e.g. hand switches) or as bus switches (or also for e.g. alarm notifications). The desired behaviour can be defined precisely through selection of the response times in Standard, Comfort or Deadman mode.

    Models:

    No. 70137 KNX S4-B10 230 V, 4 MF outputs, 10 binary inputs
    No. 70380 KNX S1-B2 230 V, 1 MF output, 2 binary inputs
    No. 70381 KNX S2-B6 230 V, 2 MF outputs, 6 binary inputs

    16734
    70380 MULTIFUNCTIONAL KNX ACTUATOR, 1 MF OUTPUT, 2 BINARY INPUTS SIN FAMILIA
    17675 70601 Cala KNX Ambient Climate Sensor and Control SENSORS

    Cala KNX

    KNX Ambient Climate Sensor and Control

    The Sensor with Cala KNX display for the KNX bus system measures various ambient climate. Via the bus, the indoor sensor can receive external values and process them further with its own data to a total value (mixed value, eg room average). All measured values can be used for the control of threshold value-dependent switching outputs. States can be linked via AND logic gates and OR logic gates. Multi-functional modules change input data as required by means of calculations, querying a condition, or converting the data point type. In addition, an integrated manipulated variable comparator can compare and output variables that were received via communication objects.

    Integrated PI-controllers control ventilation (according to humidity or CO2-concentration) and/or heating/cooling (according to temperature), depending on the respective model.

    Cala KNX features a touch display that shows various display and control pages depending on the individual configuration. There is one page available that shows the current measured values, a menu area to adjust device settings and pages with touch control elements for internal temperature control, for light (manual switching or dimming), for shades or windows (manual operation).

    Cala KNX is supplemented with a frame of the switch series used in buildings, and thus fits seamlessly into the interior fittings.

    Models:

    N° 70601 Cala KNX T, black with temperature sensor
    N° 70602 Cala KNX TH, black with temperature and humidity sensor
    N° 70603 Cala KNX AQS/TH, black with sensor for temperature, humidity and CO2

    Delivery without frame

    17675
    70601 CALA KNX AMBIENT CLIMATE SENSOR AND CONTROL SENSORS
    17676 70602 Cala KNX TH, black with temperature and humidity sensor SENSORS

    The Sensor with Cala KNX display for the KNX bus system measures various ambient climate. Via the bus, the indoor sensor can receive external values and process them further with its own data to a total value (mixed value, e.g. room average). All measured values can be used for the control of threshold value-dependent switching outputs. States can be linked via AND logic gates and OR logic gates. Multi-functional modules change input data as required by means of calculations, querying a condition, or converting the data point type. In addition, an integrated manipulated variable comparator can compare and output variables that were received via communication objects.

    Integrated PI-controllers control ventilation (according to humidity or CO2-concentration) and/or heating/cooling (according to temperature), depending on the respective model.

    Cala KNX features a touch display that shows various display and control pages depending on the individual configuration. There is one page available that shows the current measured values, a menu area to adjust device settings and pages with touch control elements for internal temperature control, for light (manual switching or dimming), for shades or windows (manual operation).

    Cala KNX is supplemented with a frame of the switch series used in buildings, and thus fits seamlessly into the interior fittings.

    Models:

    N° 70601 Cala KNX T, black with temperature sensor
    N° 70602 Cala KNX TH, black with temperature and humidity sensor
    N° 70603 Cala KNX AQS/TH, black with sensor for temperature, humidity and CO2

    Delivery without frame

    17676
    70602 CALA KNX TH, BLACK WITH TEMPERATURE AND HUMIDITY SENSOR SENSORS
    17677 70603 Cala KNX AQS/TH, black with sensor for temperature, humidity and CO2 SENSORS

    Cala KNX AQS/TH functions (N° 70603):

    • Measuring the CO2-concentration of the air, the temperature and air humidity (relative, absolute), each with mixed value calculation. The share of internal measurement value and external value can be set as a percentage
    • Bus message, whether the values for temperature and air humidity are within the comfort field (DIN 1946). Dew point calculation
    • Threshold values can be adjusted per parameter or via communication objects
    17677
    70603 CALA KNX AQS/TH, BLACK WITH SENSOR FOR TEMPERATURE, HUMIDITY AND CO2 SENSORS
    17678 70179 KNX T-Objekt-UP Temperature Sensor SENSORS
    The Temperature Sensor KNX T-Objekt-UP measures ambient temperature. The sensor can receive an external measured value via the bus and process it with the own data to an overall temperature (mixed value).
    The KNX T-Objekt-UP provides three switching outputs with adjustable threshold values. The switching outputs and further communication objects can be linked via AND and OR logic gates. Additionally, an integrated actuating variable comparator can compare and output values that are received via communication objects. The sensor has got a PI controller for heating and cooling.
    The device is completed with a frame and cover of the switching series installed in the building and thus merges with the interior.
    17678
    70179 KNX T-OBJEKT-UP TEMPERATURE SENSOR SENSORS
    17679 70406 Salva KNX TH with temperature and humidity sensor SENSORS

    Salva KNX

    KNX Smoke Detector,temperature and air humidity

    Salva KNX TH and Salva KNX basic are smoke detector sensors for the KNX building bus system. Their compact housing accommodates the sensors, evaluation circuits and bus-coupling electronics. The smoke alarm features an automatic evaluation sensor system for early and accurate fire alarms. Alarms are output as a local acoustic signal and a bus telegram. Salva KNX basic signals smoke alarm, Salva KNX-TH signals smoke and/or heat alarm.

    AND logic gates and OR logic gates allow for a link between data and statuses. Multi-functional modules change input data as required by means of calculations, querying a condition, or converting the data point type.

    The Salva KNX TH model additionally features integrated sensors for temperature and air humidity. The measured values can be used for the control of limit-dependent switching outputs. The devices have PI controls for heating/cooling (depending on temperature) and for ventilation (depending on humidity).

    17679
    70406 SALVA KNX TH WITH TEMPERATURE AND HUMIDITY SENSOR SENSORS
    17680 70203 Multifunctional KNX Actuators 4 inputs for binary contact or temperature sensor 10 A (resistive load) ACTUATORS - OUTPUTS

    KNX S1R-B4-UP:

    • Actuators KNX S1R 230 V with integrated façade control have a multifunctional
      output which can connect to either a drive with Up/Down control (blinds, awnings,
      shutters, windows) or two switchable devices (On/Off for light and ventilation). Because the output is designed to be free of potential, other systems can also be con-
      trolled, e.g. via the manual switch input on a motor control unit.
      Automation can be specified externally or internally. Internally, there are numerous op-
      tions available for blocking, locking (e.g. master-slave) and priority definitions (e.g.
      manual-automatic). Scenes can be saved and called up via the bus (scene control with
      16 scenes per drive).
      The KNX S1R-B4-UP and KNX S1R-B2-UP models are equipped with inputs which
      are used as bus inputs (buttons, alarms, etc.) or for T-NTC temperature sensors. The
      KNX S1R-UP model does not have any analogue/digital inputs.
      Functions:
      • Free of potential multifunctional output for a 230 V drive (shading,
      windows) or connection of two switchable devices (light, fan)
      • Relays switch, with little wear, during the zero-voltage transition.
      • Inputs for binary contact or temperature sensor (not on KNX S1R-UP)
      • Automatic runtime measurement of the drives for positioning (incl. fault
      reporting object)
      • Position feedback (movement position, also slat position for shutters)
      • Position storage (movement position) via 1-bit object (storage and call-up
      e.g. via buttons)
      • Parameters for taking drive and mechanics downtimes into account
      • Control via internal or external automation functions
      • Integrated shade control with slat adjustment for shutters based on the
      position of the sun
      • Scene control for movement position with 16 scenes per drive (also slat
      position for shutters)
      • Mutual locking of two drives using zero position sensors prevents collisions
      e.g. of shade and window (master–slave)
      • Blocking objects and alarm reports have different priorities, so safety functions
      always take precedence (e.g. wind block)
      • Manual or automatic priority setting via time or communication object
      • 4 temperature switching outputs in the application program with
      adjustable threshold values (presetting the parameters or communication
      object)
      • 4 AND and 4 OR logic gates, each with 4 inputs. 16 logic inputs (in the form
      of communication objects) are available as inputs for the logic gates. The
      output of each gate can be configured optionally as 1-bit or 2 x 8-bit
      Configuration is made using the KNX software ETS. The product file can be down-
      loaded from the Elsner Elektronik website on www.elsner-elektronik.de in the “Ser-
      vice” menu

      . Technical specification

      The product is compliant with the provisions of EU guidelines.
      Housing Plastic
      Colour White
      Assembly Flush-mounted (in connector socket Ø 60 mm, 60 mm
      deep)
      Protection category IP 20
      Dimensions approx. 50 x 50 x 54 (W × H × D, mm)
      Weight approx. 100 g
      Ambient temperature Operation -20…+70°C, storage -30…+85°C
      Ambient humidity 5...80% RH, non-condensing
      Operating voltage KNX bus voltage
      Current at the bus 10 mA
      Output 1 × output, free of potential
      with 2 connections for drive up/down or 2 devices
      (power supply, PE/N/1/2).
      Secured by a microfuse T4.0 A.
      Can withstand a total of max. 10 A (resistive load),
      switch-on current totally max. 4 A at = 20ms.
      Minimum current for run-
      time measurement
      AC effektive 200 mA
      Inputs KNX S1R-UP 230V: no inputs
      KNX S1R-B2-UP 230V: 2× analogue/digital.
      KNX S1R-B4-UP 230V: 4× analogue/digital.

    17680
    70203 MULTIFUNCTIONAL KNX ACTUATORS 4 INPUTS FOR BINARY CONTACT OR TEMPERATURE SENSOR 10 A (RESISTIVE LOAD) ACTUATORS - OUTPUTS
    17681 70206 KNX S1R-B4-UP 24 V Actuator for 24 V DC Motor Load capacity: max. 5 A ACTUATORS - OUTPUTS

    The Actuator KNX S1R-B4-UP 24 V with integrated façade controller regulates the 12 or 24 V DC motor for a shutter, an awning, a blind or window. Because the output is designed to be potential-free, other systems can also be controlled, e.g. via the manual switch input on a motor control unit.

    Automation is specified externally or internally. Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definitions (e.g. manual-automatic). Scenes are saved and called up via the bus (scene control with 16 scenes per drive).

    The KNX S1R-B4-UP 24 V has four inputs that are used as binary inputs (switches, alarm messages etc.) or as analogue inputs for T-NTC temperature sensors

    • Potential-free output with polarity changer for a 12 V DC or 24 V DC drive (shade, window) Load capacity: max. 5 A
    • 4 inputs for binary contacts or temperature sensor
    •  Automatic runtime measurement of the drives for positioning (incl. fault reporting object)
    • Position feedback (movement position, also slat position for shutters)
    • Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)
    • Parameters for taking drive and mechanics downtimes into account
    • Control via internal or external automation functions
    • Integrated shade control with slat tracking according to sun position for shutters
    • Scene control for movement position with 16 scenes per drive (also slat position for shutters)
    • Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)
    • Blocking objects and alarm reports have different priorities, so safety functions always take precedence (e.g. wind block)
    • Manual or automatic priority setting via time or communication object
    • 4 temperature switching outputs in the application program with adjustable threshold values (presetting the parameters or communication object)
    • 4 AND and 4 OR logic gates each with 4 inputs. 16 logic inputs (in the form of communication objects) are available as inputs for the logic gates. The output from each gate can be configured optionally as 1-bit or 2 x 8-bit
    • Configuration is made using the KNX software ETS
    17681
    70206 KNX S1R-B4-UP 24 V ACTUATOR FOR 24 V DC MOTOR LOAD CAPACITY: MAX. 5 A ACTUATORS - OUTPUTS
    17682 70207 S1E-UP 230 V shader actuator Electronic output for a 230 V-drive (no imputs) ACTUATORS - OUTPUTS

    KNX Actuator for Shading Element or Window with 1 Channel for a 230 V Drive (Electronical Output), with Internal Automatic Functions

    The 230 V AC motor of a blind, awning, a roller shutter or window is controlled with the KNX S1E 230 V actuators with integrated façade control. The electronic output switches silently. The automatic for the drive control can be specified externally or internally. There are numerous options for blocking, locking (eg master-slave) and priority settings (eg manual-automatic). Scenes can be stored and recalled via the bus (scene control with 16 scenes per drive). The KNX S1E-B4-UP and KNX S1E-B2-UP models have inputs that are used as bus inputs (push buttons, alarm messages, etc.) or for temperature sensors T-NTC. The KNX S1E-UP has no analog / digital inputs.

    • Electronic output for a 230 V-drive (shade, window)
    • Inputs for binary contact or temperature sensor (not on KNX S1E-UP)
    • Automatic runtime measurement of the drives for positioning (incl. fault reporting object)
    • Position feedback (movement position, also slat position for shutters)
    • Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)
    • Parameters for taking drive and mechanics downtimes into account
    • Control via internal or external automation functions
    • Integrated shade control with slat tracking according to sun position for shutters
    • Scene control for movement position with 16 scenes per drive (also slat position for shutters)
    • Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)
    • Blocking objects and alarm reports have different priorities, so safety functions always take precedence (e.g. wind block)
    • Manual or automatic priority setting via time or communication object
    • 4 temperature switching outputs in the application program with adjustable threshold values (presetting the parameters or communication object)
    • 4 AND and 4 OR logic gates each with 4 inputs. 16 logic inputs (in the form of communication objects) are available as inputs for the logic gates. The output from each gate can be configured optionally as 1-bit or 2 x 8-bit
    • Configuration is made using the KNX software ETS
    17682
    70207 S1E-UP 230 V SHADER ACTUATOR ELECTRONIC OUTPUT FOR A 230 V-DRIVE (NO IMPUTS) ACTUATORS - OUTPUTS
    17683 70208 KNX S1E-B2-UP 230 V, 2 A/D shader actuator, 2 imputs ACTUATORS - OUTPUTS

    Electronic output for a 230 V-drive (shade, window) 2 Inputs for binary contact or temperature sensor

  • Automatic runtime measurement of the drives for positioning (incl. fault reporting object)
  • Position feedback (movement position, also slat position for shutters)
  • Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)
  • Parameters for taking drive and mechanics downtimes into account
  • Control via internal or external automation functions
  • Integrated shade control with slat tracking according to sun position for shutters
  • Scene control for movement position with 16 scenes per drive (also slat position for shutters)
  • Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)
  • Blocking objects and alarm reports have different priorities, so safety functions always take precedence (e.g. wind block)
  • Manual or automatic priority setting via time or communication object
  • 4 temperature switching outputs in the application program with adjustable threshold values (presetting the parameters or communication object)
  • 4 AND and 4 OR logic gates each with 4 inputs. 16 logic inputs (in the form of communication objects) are available as inputs for the logic gates. The output from each gate can be configured optionally as 1-bit or 2 x 8-bit
  • Configuration is made using the KNX software ETS
  • 17683
    70208 KNX S1E-B2-UP 230 V, 2 A/D SHADER ACTUATOR, 2 IMPUTS ACTUATORS - OUTPUTS
    17684 70209 KNX S1E-B4-UP 230 V,shade, 4 imputs A/D ACTUATORS - OUTPUTS
    • Electronic output for a 230 V-drive (shade, window)
    • 4 Inputs for binary contact or temperature sensor
    • Automatic runtime measurement of the drives for positioning (incl. fault reporting object)
    • Position feedback (movement position, also slat position for shutters)
    • Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)
    • Parameters for taking drive and mechanics downtimes into account
    • Control via internal or external automation functions
    • Integrated shade control with slat tracking according to sun position for shutters
    • Scene control for movement position with 16 scenes per drive (also slat position for shutters)
    • Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)
    • Blocking objects and alarm reports have different priorities, so safety functions always take precedence (e.g. wind block)
    • Manual or automatic priority setting via time or communication object
    • 4 temperature switching outputs in the application program with adjustable threshold values (presetting the parameters or communication object)
    • 4 AND and 4 OR logic gates each with 4 inputs. 16 logic inputs (in the form of communication objects) are available as inputs for the logic gates. The output from each gate can be configured optionally as 1-bit or 2 x 8-bit
    • Configuration is made using the KNX software ETS
    17684
    70209 KNX S1E-B4-UP 230 V,SHADE, 4 IMPUTS A/D ACTUATORS - OUTPUTS
    17688 70193 KNX WS1000 Style Building Contorl System VISUALIZATION

    KNX WS1000 Style building controller invitation to tender

     

    Control panel for KNX with integrated controller functions. Colour touch display (8.4 inches) for operation and automatic function setting. Default setting via ETS.

    Indoor automatic functions for shading (sun/eye protection) and window exhaust air extraction for 22 channels/façades. Lighting control and time functions. KNX connection for data transfer.

    Also 32 wireless channels (Elsner RF wireless for optional exhaust air extraction units, motor control units, sensors, remote control). Direct connection of a weather station possible (P04i-GPS).

    Operating voltage: 230V AC Central unit dimensions 270 x 185 x 9 (W x H x installation depth in mm), surface or cavity wall mounting, dimensions of surface mounting box 254 x 171 x 85 (W x H x D in mm). Colour white/grey.

     

    Manufactured by: Elsner Elektronik (www.elsner-elektronik.de)

    Type: KNX WS1000 Style

    17688
    70193 KNX WS1000 STYLE BUILDING CONTORL SYSTEM VISUALIZATION
    17689 70194 KNX WS1000 Style building controller SIN FAMILIA

    Control panel for KNX with integrated controller functions. Colour touch display (8.4 inches) for operation and automatic function setting. Default setting via ETS.

    Indoor automatic functions for shading (sun/eye protection) and window exhaust air extraction for 22 channels/façades. Lighting control and time functions. KNX connection for data transfer.

    Also 32 wireless channels (Elsner RF wireless for optional exhaust air extraction units, motor control units, sensors, remote control). Direct connection of a weather station possible (P04i-GPS).

    Operating voltage: 230V AC Central unit dimensions 270 x 185 x 9 (W x H x installation depth in mm), surface or cavity wall mounting, dimensions of surface mounting box 254 x 171 x 85 (W x H x D in mm). Colour white/grey.

     

    Manufactured by: Elsner Elektronik (www.elsner-elektronik.de)

    Type: KNX WS1000 Style

    17689
    70194 KNX WS1000 STYLE BUILDING CONTROLLER SIN FAMILIA
    17690 70197 KNX Touch One Style - Touch Panel for Room Automation VISUALIZATION

     

    The Room Controller KNX Touch One Style enables control of the KNX building technology for one room by means of a touch-sensitive display screen. The unit provides

    integrated control functions which can also be directly set on the display (automatic).

    Basic settings are made by the installer in the ETS.

    The KNX Touch OneStyle with integrated indoor sensor (temperature, air humidity) includes an internal automated operation function for shades (sun/privacy shades) and

    room climate control (heating, cooling, ventilation), internal light control as well as bus functions for time and scene control. 4 binary inputs enable the connection of conventional

    buttons, switches and window contacts.

    Eight universal pages with up to eight functions per page can be created to ensure the orderly operation and display of the function and object assignments.

    The Remo 8 eight-channel wireless remote control can be used with the KNX Touch OneStyle for remote control of the drives.

    Functions

    • Internal automatic shade controls (protection from the sun/privacy)

    • Room climate control (heating, cooling, ventilation)

    • Internal lighting control

    • Integrated interior sensors (temperature, air humidity)

    • Bus functions for time and scene control

    • Universal menu to display and operate the function and object assignments

    • Bus functions: Actuating variable comparator, AND/OR logic Die Konfiguration erfolgt mit der KNX-Software ETS. Die Produktdatei steht auf der

    Homepage von Elsner Elektronik unter www.elsner-elektronik.de im Menübereich Service" zum Download bereit.

    17690
    70197 KNX TOUCH ONE STYLE - TOUCH PANEL FOR ROOM AUTOMATION VISUALIZATION
    17691 70190 KNX Interface for WS1000 Color/Style SIN FAMILIA
    The KNX Interface for WS1000 allows for communication between the WS1000 Color or WS1000 Style Control System and the KNX bus system. On the one hand, data of the control unit can be sent to the KNX bus (e. g. weather data). On the other hand, the WS1000 can control drives in the KNX system directly and use sensor data from the KNX system.
    17691
    70190 KNX INTERFACE FOR WS1000 COLOR/STYLE SIN FAMILIA
    17692 70249 KNX B8-TH KNX interface, 8 binary and 2 sensor inputs INPUTS
    The  Interface KNX B8-TH: has eight binary inputs and two additional sensor inputs
    for temperature or temperature and air humidity. They are used to integrate signals
    and values from conventional buttons and sensors into the KNX building bus.
    The application software of the Interface KNX B8-TH:
    contains both switch outputs for temperature and humidity as well as PI
    controllers for heating/cooling and ventilation. The binary inputs can be configured as switches,
    up/down buttons, dimmers or encoders in various configurations.
    Due to its compact design, the interface fits into a switch box. The binary contacts are
    connected using the cables supplied with the delivery.
    17692
    70249 KNX B8-TH KNX INTERFACE, 8 BINARY AND 2 SENSOR INPUTS INPUTS
    17693 70143 KNX PS640 USB: without bus functions. With USB interface. SYSTEM DEVICES

    The power supplies deliver a 29 V bus voltage for the KNX system and 24 V DC supply voltage for 24 V devices. Output current max. 640 mA. With display and key pad. Reset on the device possible. Installation on DIN rail.
    KNX PS640: without bus functions.
    KNX PS640+: with bus functions (transfer of malfunction messages/operating, time/period reset via the bus).
    KNX PS640 USB: without bus functions. With USB interface.
    KNX PS640+USB: with bus functions (transfer of malfunction messages/operating data, time/period reset via the bus) and USB interface.
    KNX PS640-IP: without bus functions. With Ethernet interface (RJ45 connector). Allows for routing (Ethernet as fast backbone for KNX data), use as line coupler, tunneling (bus access over IP).
    KNX PS640+IP: with bus functions (transfer of malfunction messages/operating data, time/period reset via the bus) and Ethernet interface (RJ45 connector). Allows for routing (Ethernet as fast backbone for KNX data), use as line coupler, tunneling (bus access over IP).

    17693
    70143 KNX PS640 USB: WITHOUT BUS FUNCTIONS. WITH USB INTERFACE. SYSTEM DEVICES
    17694 60121 WS1000 Color Building Control System 4 drive outputs 230 V VISUALIZATION
    Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
    Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
    The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow
    17694
    60121 WS1000 COLOR BUILDING CONTROL SYSTEM 4 DRIVE OUTPUTS 230 V VISUALIZATION
    17695 60122 WS1000 Color Building Control System 6 drive outputs 230 V VISUALIZATION

    Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
    Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
    The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

    17695
    60122 WS1000 COLOR BUILDING CONTROL SYSTEM 6 DRIVE OUTPUTS 230 V VISUALIZATION
    17696 60123 WS1000 Color Building Control System 8 drive outputs 230 V VISUALIZATION

    Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
    Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
    The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

    17696
    60123 WS1000 COLOR BUILDING CONTROL SYSTEM 8 DRIVE OUTPUTS 230 V VISUALIZATION
    17698 60125 WS1000 Color Building Control System 4 drive outputs 230 V VISUALIZATION

    Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
    Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
    The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

    17698
    60125 WS1000 COLOR BUILDING CONTROL SYSTEM 4 DRIVE OUTPUTS 230 V VISUALIZATION
    17699 60126 WS1000 Color Building Control System 6 drive outputs 230 V SIN FAMILIA

    Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
    Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
    The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

    17699
    60126 WS1000 COLOR BUILDING CONTROL SYSTEM 6 DRIVE OUTPUTS 230 V SIN FAMILIA
    17700 60127 WS1000 Color Building Control System 8 drive outputs 230 V VISUALIZATION

    Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
    Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
    The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

    17700
    60127 WS1000 COLOR BUILDING CONTROL SYSTEM 8 DRIVE OUTPUTS 230 V VISUALIZATION
    17701 60128 WS1000 Color Building Control System 10 drive outputs 230 V SIN FAMILIA

    Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
    Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
    The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

    17701
    60128 WS1000 COLOR BUILDING CONTROL SYSTEM 10 DRIVE OUTPUTS 230 V SIN FAMILIA
    17704 60135 N° 60135 WS1 Color-1, white, for 1 drive 230 v Building Control Systems VISUALIZATION
    Apart from shading and ventilation the WS1 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting. The WS1 Color includes the operating panel with integrated indoor sensor and the weather station. Further separate indoor sensors can be wirelessly integrated into the system and allow different climate zones to be created (individual room control).
    The touch display makes operation of the WS1 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow
    17704
    60135 N° 60135 WS1 COLOR-1, WHITE, FOR 1 DRIVE 230 V BUILDING CONTROL SYSTEMS VISUALIZATION
    17714 30520 T-UP Temperature Sensor for KNX B8-TH RF
    Sensors for Interface KNX B8-TH. Installation in a socket, for common switch programs. Delivery
    without frame.
    T-UP: Temperature Sensor.
    TH-UP: Temperature/humidity Sensor
    17714
    30520 T-UP TEMPERATURE SENSOR FOR KNX B8-TH RF
    17718 30131 P04i distributor Weather data distributor for P04i CONTROLLERS

    The P04i distributor operates four WS1, WS1000 Color or (KNX) WS1000 Style controls with a P04i-GPS weather station. The weather data is provided to all connected controls.
    17718
    30131 P04I DISTRIBUTOR WEATHER DATA DISTRIBUTOR FOR P04I CONTROLLERS
    17719 30132 P04i -Data Collector SIN FAMILIA
    Weather data collector comprising 5 data inputs (1 input for P04i-GPS, 4 inputs for P04i-W) and 1 data
    output (for WS1 and WS1000). Operating voltage: 230 V AC. Installation on DIN rail
    17719
    30132 P04I -DATA COLLECTOR SIN FAMILIA
    17978 70201 actuator With relay output S1R-UP Free of potential multifunctional output (no imputs) max. 4A (resistive load), ACTUATORS - OUTPUTS

    Actuators KNX S1R 230 V with integrated façade control have a multifunctional
    output which can connect to either a drive with Up/Down control (blinds, awnings,
    shutters, windows) or two switchable devices (On/Off for light and ventilation). Because the output is designed to be free of potential, other systems can also be con-
    trolled, e.g. via the manual switch input on a motor control unit.
    Automation can be specified externally or internally. Internally, there are numerous op-
    tions available for blocking, locking (e.g. master-slave) and priority definitions (e.g.
    manual-automatic). Scenes can be saved and called up via the bus (scene control with
    16 scenes per drive).
    The KNX S1R-B4-UP and KNX S1R-B2-UP models are equipped with inputs which
    are used as bus inputs (buttons, alarms, etc.) or for T-NTC temperature sensors. The
    KNX S1R-UP model does not have any analogue/digital inputs.
    Functions:
    • Free of potential multifunctional output for a 230 V drive (shading,
    windows) or connection of two switchable devices (light, fan)
    • Relays switch, with little wear, during the zero-voltage transition.
    • Inputs for binary contact or temperature sensor (not on KNX S1R-UP)
    • Automatic runtime measurement of the drives for positioning (incl. fault
    reporting object)
    • Position feedback (movement position, also slat position for shutters)
    • Position storage (movement position) via 1-bit object (storage and call-up
    e.g. via buttons)
    • Parameters for taking drive and mechanics downtimes into account
    • Control via internal or external automation functions
    • Integrated shade control with slat adjustment for shutters based on the
    position of the sun
    • Scene control for movement position with 16 scenes per drive (also slat
    position for shutters)
    • Mutual locking of two drives using zero position sensors prevents collisions
    e.g. of shade and window (master–slave)
    • Blocking objects and alarm reports have different priorities, so safety functions
    always take precedence (e.g. wind block)
    • Manual or automatic priority setting via time or communication object
    • 4 temperature switching outputs in the application program with
    adjustable threshold values (presetting the parameters or communication
    object)
    • 4 AND and 4 OR logic gates, each with 4 inputs. 16 logic inputs (in the form
    of communication objects) are available as inputs for the logic gates. The
    output of each gate can be configured optionally as 1-bit or 2 x 8-bit
    Configuration is made using the KNX software ETS. The product file can be down-
    loaded from the Elsner Elektronik website on www.elsner-elektronik.de in the “Ser-
    vice” menu

    . Technical specification

    The product is compliant with the provisions of EU guidelines.
    Housing Plastic
    Colour White
    Assembly Flush-mounted (in connector socket Ø 60 mm, 60 mm
    deep)
    Protection category IP 20
    Dimensions approx. 50 x 50 x 54 (W × H × D, mm)
    Weight approx. 100 g
    Ambient temperature Operation -20…+70°C, storage -30…+85°C
    Ambient humidity 5...80% RH, non-condensing
    Operating voltage KNX bus voltage
    Current at the bus 10 mA
    Output 1 × output, free of potential
    with 2 connections for drive up/down or 2 devices
    (power supply, PE/N/1/2).
    Secured by a microfuse T4.0 A.
    Can withstand a total of max. 4A (resistive load),
    switch-on current totally max. 4 A at = 20ms.
    Minimum current for run-
    time measurement
    AC effektive 200 mA
    Inputs KNX S1R-UP 230V: no inputs
    KNX S1R-B2-UP 230V: 2× analogue/digital.
    KNX S1R-B4-UP 230V: 4× analogue/digital.
    max. output length 10 m
    Setting range for the T-NTC
    temperature sensor on the
    input
    -30°C...+80°C
    Data output KNX +/- bus connector terminal

    17978
    70201 ACTUATOR WITH RELAY OUTPUT S1R-UP FREE OF POTENTIAL MULTIFUNCTIONAL OUTPUT (NO IMPUTS) MAX. 4A (RESISTIVE LOAD), ACTUATORS - OUTPUTS
    18207 70475 Display Corlo Touch KNX 5in WL with WiFI connectivity VISUALIZATION

    The Display Corlo Touch KNX 5in for the KNX system offers a variety of options for its use: Its touch-sensitive glass interface means that it can be used as a normal switch. The high resolution display is ideal for displaying text, images or graphics. In addition to current readings and messages, the KNX bus system can also display photographs, for example. Concurrently, you can set up the Corlo Touch KNX 5in as a control center for automatic shading, ventilation and air conditioning regulation.

    With the Corlo Touch KNX 5in WL model, you can also show network content on the display using the WLAN connection, e.g. web pages, IP camera images or visualizations. The Corlo Touch KNX 5in WL display screen can, for example, be shown on a Smartphone, if a VPN connection is provided externally.

    Corlo Mobile App
    for Corlo Touch KNX 5in WL is available in Google Play Store (Android) and in the App Store (Apple). Requirements: Corlo Touch KNX 5in WL. Terminal (smart phone, tablet PC) with Wi-Fi access and operating system Android 3.0 or iOS 8.0 (and up).

    Housing : Glass: real glass, tempered
    Housing: plastic
    Display: Visible diagonal: 5 inches Resolution: 800 × 480 pixel
    Viewing Angle: 12 o’clock viewing direction
    Opening angle x: -70° to +70° typ.
    Opening angle y: -60° to +60° typ.
    Colours
    • Black glass, edge glossy black
    • Custom colours on request
    Assembly: Flush mounting (Wall installation in junction box Ø 60 mm)


    Dimensions
    Housing overall approx. 133 × 97 × 35 (W × H × D, mm),
    Mounting depth approx. 20 mm
    Weight display unit Corlo Touch KNX 5in WL: approx. 210 g
    Ambient temperature: Operation 0...+50°C, storage -10...+50°C
    Ambient humidity: max. 95% RH, avoid condensation
    Operating voltage: 24 V DC ±10%
    Power consumption Corlo Touch KNX 5in
    • approx. 2.7 W maximum (when ambient lighting 100% white, display brightness 100%)
    • approx. 2.0 W in normal operation (when ambient lighting off, display brightness 50%)
    • approx. 1.4 W in standby operation (when ambient lighting off, display off)
    (was measured with 24 V auxiliary voltage)
    Power consumption Corlo Touch KNX 5in WL
    • approx. 3.5 W maximum (when ambient lighting 100% white, display brightness 100%)
    • approx. 2.4 W in normal operation (when ambient lighting off, display brightness 50%)
    • approx. 1.9 W in standby operation (when ambient lighting off, display off)
    (was measured with 24 V auxiliary voltage)
    Data output/ bus communication: KNX +/- Bus connector terminal
    Communication objects: 1022
    Other data interfaces: Micro SD
    Inputs: 4× Analog/digital, max. cable length 10 m
    Setting range of temperature sensor T-NTC at input of Corlo Touch: -40°C...+80°C

    18207
    70475 DISPLAY CORLO TOUCH KNX 5IN WL WITH WIFI CONNECTIVITY VISUALIZATION
    18208 70481 Display Corlo Touch KNX 5in VISUALIZATION

    The Display Corlo Touch KNX 5in for the KNX system offers a variety of options for its use: Its touch-sensitive glass interface means that it can be used as a normal switch. The high resolution display is ideal for displaying text, images or graphics. In addition to current readings and messages, the KNX bus system can also display photographs, for example. Concurrently, you can set up the Corlo Touch KNX 5in as a control center for automatic shading, ventilation and air conditioning regulation.

    With the Corlo Touch KNX 5in WL model, you can also show network content on the display using the WLAN connection, e.g. web pages, IP camera images or visualizations. The Corlo Touch KNX 5in WL display screen can, for example, be shown on a Smartphone, if a VPN connection is provided externally.

    Corlo Mobile App
    for Corlo Touch KNX 5in WL is available in Google Play Store (Android) and in the App Store (Apple). Requirements: Corlo Touch KNX 5in WL. Terminal (smart phone, tablet PC) with Wi-Fi access and operating system Android 3.0 or iOS 8.0 (and up).

    Housing : Glass: real glass, tempered
    Housing: plastic
    Display: Visible diagonal: 5 inches Resolution: 800 × 480 pixel
    Viewing Angle: 12 o’clock viewing direction
    Opening angle x: -70° to +70° typ.
    Opening angle y: -60° to +60° typ.
    Colours
    • Black glass, edge glossy black
    • Custom colours on request
    Assembly: Flush mounting (Wall installation in junction box Ø 60 mm)


    Dimensions
    Housing overall approx. 133 × 97 × 35 (W × H × D, mm),
    Mounting depth approx. 20 mm
    Weight display unit Corlo Touch KNX 5in WL: approx. 210 g
    Ambient temperature: Operation 0...+50°C, storage -10...+50°C
    Ambient humidity: max. 95% RH, avoid condensation
    Operating voltage: 24 V DC ±10%
    Power consumption Corlo Touch KNX 5in
    • approx. 2.7 W maximum (when ambient lighting 100% white, display brightness 100%)
    • approx. 2.0 W in normal operation (when ambient lighting off, display brightness 50%)
    • approx. 1.4 W in standby operation (when ambient lighting off, display off)
    (was measured with 24 V auxiliary voltage)
    Power consumption Corlo Touch KNX 5in WL
    • approx. 3.5 W maximum (when ambient lighting 100% white, display brightness 100%)
    • approx. 2.4 W in normal operation (when ambient lighting off, display brightness 50%)
    • approx. 1.9 W in standby operation (when ambient lighting off, display off)
    (was measured with 24 V auxiliary voltage)
    Data output/ bus communication: KNX +/- Bus connector terminal
    Communication objects: 1022
    Other data interfaces: Micro SD
    Inputs: 4× Analog/digital, max. cable length 10 m
    Setting range of temperature sensor T-NTC at input of Corlo Touch: -40°C...+80°C

    18208
    70481 DISPLAY CORLO TOUCH KNX 5IN VISUALIZATION
    18471 70701 KNX RF LC-TP Media Coupler for KNX TP / KNX RF SYSTEM DEVICES

    The media coupler KNX RF LC-TP connects the wired KNX installation (KNX TP, twisted pair) with the KNX radio (KNX RF). The media coupler is used to forward messages from TP to RF and from RF to TP. The KNX RF LC-TP uses the KNX RF S standard.

     The KNX RF LC-TP uses multiple display pages to show the addressing, traffic and message flow. The housing is supplemented with a frame of the switch series used in buildings, and thus fits seamlessly into the interior fittings

    18471
    70701 KNX RF LC-TP MEDIA COUPLER FOR KNX TP / KNX RF SYSTEM DEVICES
    18472 70711 KNX RF-MSG-ST Radio Actuator ACTUATORS - OUTPUTS

    The KNX RF-MSG-ST is a radio actuator for KNX radio (KNX RF). The actuator controls one drive (blind, shutter, awning or window).

    The KNX RF-MSG-ST uses the KNX RF S standard.

    • 1 connection for 230 V-drive (STAK3)
    • Reception of the control signal via radio KNX RF
    • Automatic runtime measurement of the drives for positioning (incl. fault reporting object)
    • Position feedback (movement position, also slat position for shutters)
    • Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)
    • Scene control for movement position with 16 scenes per drive (also slat position for shutters)
    • Blocking objects and alarm reports have different priorities, so safety functions always take precedence (e.g. wind block)
    • Manual or automatic priority setting via time or communication object
    • Brief time limit (movement command blocked) and 2 movement limits
    • Configuration is made using the KNX software ETS 5

     

    18472
    70711 KNX RF-MSG-ST RADIO ACTUATOR ACTUATORS - OUTPUTS
    18473 70541 Shutter actuator. Outputs: 2 x Up/Down, free of potential, max. 30 V DC or 230 V AC ACTUATORS - OUTPUTS

    The drives of blinds, awnings, roller shutters or windows are controlled with the actuator KNX S2 with integrated façade control. The connected drives can be directly operated via the push button pairs of the actuator.

    Due to the potential-free design of the outputs, drives up to 30 V DC and up to 230 V AC can be controlled in exactly the same way as other systems (eg a hand-held input of a motor control unit).

    The automatic for shading or window ventilation can be set externally or internally. Internally there are numerous options for blocking, locking (eg master-slave) and priority settings (eg manual-automatic). Scenes can be saved and recalled via the bus (scene control with 16 scenes per drive).

    features:

    • 2 potential-free outputs for shading or window drives

    • Keypad with button pairs and status LEDs

    • Position feedback (travel position, for Venetian blinds also slat position)

    • Position memory (travel position) via a 1-bit object (storage and retrieval eg via pushbutton)

    • Control by internal or external automatic control

    • Integrated shading control for each drive output (with slat tracking after sun blinds for blinds)

    • Integrated window ventilation control

    • Scene control for driving position with 16 scenes per drive (blinds also with slat position)

    • Mutual locking of two drives using zero position sensors prevents collisions, Eg from shading and window (master slave)

    • Block objects and alarm messages have different priorities so that safety functions always take precedence (eg wind lock)

    • Setting the priority of manual or automatic control over time or communication object

    • 5 security objects for each channel

    • Short-term restriction (driving command disabled) and 2 driving restriction

    18473
    70541 SHUTTER ACTUATOR. OUTPUTS: 2 X UP/DOWN, FREE OF POTENTIAL, MAX. 30 V DC OR 230 V AC ACTUATORS - OUTPUTS
    18494 70540 SHUTTER ACTUATOR. Outputs: 4 x Up/Down, free of potential, max. 30 V DC or 230 V AC. ACTUATORS - OUTPUTS

    With the Actuator KNX S4 with integrated facade control, the drives of shutters,

    awnings, blinds or windows are controlled. The connected drives can be directly operated

    with the switch pairs of the actuator.

    With the potential-free design of the outputs, drives of up to 30 VDC and 230 VAC can

    be controlled, as well as other systems (e.g. manual switch input of a motor control unit).

    The automation for the shading or window ventilation is specified externally or internally.

    Internally, there are numerous options available for blocking, locking (e.g. master-slave)

    and priority definitions (e.g. manual-automatic). Scenes are saved and called up via the bus (scene control with 16 scenes per drive).

    Functions:

    • 4 potential-free outputs for drives of shading or windows.

    • Switch panel with switch pairs and status LEDs

    • Position feedback (movement position, also slat position for shutters)

    • Position storage (movement position) via 1-bit object (storage and call-up e.g. via buttons)

    • Control via internal or external automation functions

    • Integrated shade control for each drive output (with slat tracking according to sun position for shutters)

    • Integrated window ventilation control

    • Scene control for movement position with 16 scenes per drive (also slat position for shutters)

    • Mutual locking of two drives using zero position sensors prevents collisions e.g. of shade and window (master–slave)

    • Blocking objects and alarm reports have different priorities, so that safety functions always take precedence (e.g. wind block)

    • Manual or automatic control configuration per time or communication object

    • 5 security objects for each channel

    • Brief time limit (movement command blocked) and 2 movement limits

     

    18494
    70540 SHUTTER ACTUATOR. OUTPUTS: 4 X UP/DOWN, FREE OF POTENTIAL, MAX. 30 V DC OR 230 V AC. ACTUATORS - OUTPUTS
    18495 70530 KNX S4-B10 230 V: 4 multifunctional outputs (8 devices), 10 binary inputs. ACTUATORS - OUTPUTS

    Actuator for the KNX bus system. 4 multi-function outputs, each for 1 drive (Up/Down) or 2 switchable devices (On/Off). 10 binary inputs (actuator or bus keys). Drive runtime measurement (position feedback). Storage of movement positions, 16-channel scene memory.
    External or internal setting of the automatic functions possible. Internal automatic functions with shading or window control, blocks, locks, priority stipulations, short time and movement restrictions.
    Outputs: 4 x Up/Down (8 x On/Off), 230 V AC.
    Inputs: 10 x binary, variable voltage 6...80 V DC and 6...240 V AC.
    Operating Voltage 230 V AC.
    567 communication objects.
    Rail-mounted device (6 division units) with 4 key pairs and status LEDs. Dimensions 107 x 88 x 60 (W x H x D in mm)

    Manufactured by: Elsner Elektronik (www.elsner-elektronik.de)
    Type: KNX S4-B10 230 V

    18495
    70530 KNX S4-B10 230 V: 4 MULTIFUNCTIONAL OUTPUTS (8 DEVICES), 10 BINARY INPUTS. ACTUATORS - OUTPUTS
    18496 70531 KNX S2-B6 230 V: 2 multifunctional outputs (4 devices), 6 binary inputs. ACTUATORS - OUTPUTS

    The actuators KNX S4-B10, KNX S2-B6 and KNX S1-B2 230 V with integrated façade control have multi-function outputs, push button pairs and control LEDs. A drive with up / down control (blinds, awnings, roller shutters, windows) or two switchable units (on / off with light and ventilation) can be connected to each of the multifunctional outputs. The connected drives and devices can be operated directly on the actuator and via connected hand towels.

    The automatic can be set externally or internally. Internally, numerous options are available for blocking, locking (eg master-slave) and priority settings (eg manual-automatic). Scenes can be saved and recalled via the bus (scene control with 16 scenes per drive).

    Binary inputs can be used either for direct operation (eg hand-held buttons) or as bus buttons (or for alarms, for example). The desired behavior can be precisely defined by selecting the reaction times in standard, comfort or dead man mode.

    18496
    70531 KNX S2-B6 230 V: 2 MULTIFUNCTIONAL OUTPUTS (4 DEVICES), 6 BINARY INPUTS. ACTUATORS - OUTPUTS
    18497 70532 KNX S1-B2 230 V, 1 multifunctional output, 2 binary inputs ACTUATORS - OUTPUTS

    KNX S4-B10 KNX S2-B6 | KNX S1-B2 230 V

    Actuators with multifunctional outputs and inputs

    Successor for 70137, 70180, 70181

    The actuators KNX S4-B10, KNX S2-B6 and KNX S1-B2 230 V with integrated façade control have multi-function outputs, push button pairs and control LEDs. A drive with up / down control (blinds, awnings, roller shutters, windows) or two switchable units (on / off with light and ventilation) can be connected to each of the multifunctional outputs. The connected drives and devices can be operated directly on the actuator and via connected hand towels.

    The automatic can be set externally or internally. Internally, numerous options are available for blocking, locking (eg master-slave) and priority settings (eg manual-automatic). Scenes can be saved and recalled via the bus (scene control with 16 scenes per drive).

     Binary inputs can be used either for direct operation (eg hand-held buttons) or as bus buttons (or for alarms, for example). The desired behavior can be precisely defined by selecting the reaction times in standard, comfort or dead man mode.

    18497
    70532 KNX S1-B2 230 V, 1 MULTIFUNCTIONAL OUTPUT, 2 BINARY INPUTS ACTUATORS - OUTPUTS
    18519 70199 IP KNX Interface. For Mobotix IP cameras. GATEWAYS

    The IP KNX interface serves to transmit data between the Mobotix IP cameras and the KNX bus system. For this purpose, the KNX telegrams are converted into the Ethernet protocols and sent to the LAN in which the cameras are installed (and vice versa).

    Features:

    • Communication with 8 IP cameras with 8 input and 8 output objects each

    • Transfer of the camera events to the KNX bus

    • Controlling the camera via the KNX bus

    • KNX Bus Terminal and Ethernet / IP Connection (POE)

    • Suitable for IP cameras that meet the communication requirements as

    described in the camera settings in the manual  Configuration is made using the KNX software ETS. The product file can be downloaded from the Elsner Elektronik website on www.elsner-elektronik.de in the “Service” menu.

     

    18519
    70199 IP KNX INTERFACE. FOR MOBOTIX IP CAMERAS. GATEWAYS
    8337 10110 Solexa Shading Control SENSORS
    Solexa Shading Control Complete system for control of an awning (resp. a group of awnings) or blind (resp. a group of blinds). Meteorological station1 with connection for drive. Radio connection between meteorological station and control unit. Battery-operated control unit with integrated indoor temperature sensor
    8337
    10110 SOLEXA SHADING CONTROL SENSORS
    10251 2034 4 motor connection clamps (for assembly on a top hat rail) SIN FAMILIA
    The Group Control Relay WGGS-4-H can operate up to four drives as a group.
    Connections are screwless, using cage clamp terminals.
    10251
    2034 4 MOTOR CONNECTION CLAMPS (FOR ASSEMBLY ON A TOP HAT RAIL) SIN FAMILIA
    5601 305 Temperature SensorT-KYT82 SENSORS
    T-KTY82 Temperature Sensor Sensor for indoor and outdoor applications. For use with Actuators KNX SB4T- UP or Intelligent Electronic Control Units IMSG.
    5601
    305 TEMPERATURE SENSORT-KYT82 SENSORS
    6118 2016 RACDC-H AC/DC Relay ACTUATORS - OUTPUTS
    For up to two 24 V DC motors. 24 V DC input (external power supply required),
    24 V DC output. Control with 230 V (up/down/N/PE). For assembly on
    a top hat rail
    6118
    2016 RACDC-H AC/DC RELAY ACTUATORS - OUTPUTS
    8145 2019 WG-PF Potential-free Relay ACTUATORS - OUTPUTS
    WG-PF Potential-free Relay Change-over contact for ``up`` and ``down``. Control with 230 V (up/down/N/ PE). For assembly in a junction box.
    8145
    2019 WG-PF POTENTIAL-FREE RELAY ACTUATORS - OUTPUTS
    8146 30109 Hinge Arm Mountings for meteorological stations BIG SENSORS
    Big for all meteorological stations/sensors of Elsner Elektronik. For wall/pole/beam mounting. 1 hinge, total length approx. 400 mm, powdercoated, color RAL 9016 (traffic white)
    8146
    30109 HINGE ARM MOUNTINGS FOR METEOROLOGICAL STATIONS BIG SENSORS
    10039 60511 RF remote control for touch one display, white OTHER ACCESSORIES
    For Touch Display KNX Touch One
    10039
    60511 RF REMOTE CONTROL FOR TOUCH ONE DISPLAY, WHITE OTHER ACCESSORIES
    11875 SONDA SO250 Sonda para sensor KNX SO250 SENSORS
    Sonda de 10 metros para el sensor de ultrasonidos con un área de detección de entre 12 y 250 cm., capaz de medir distancias o volúmenes en recipientes rectangulares, esféricos, cilíndricos (horizontales y verticales).
    11875
    SONDA SO250 SONDA PARA SENSOR KNX SO250 SENSORS
    12308 70264 Frame Corlo 1-gang chrome-plated glossy VISUALIZATION

    Frame Corlo 1-gang chrome-plated glossy

    12308
    70264 FRAME CORLO 1-GANG CHROME-PLATED GLOSSY VISUALIZATION
    12310 70265 Frame Corlo 2-gang chrome-plated glossy VISUALIZATION
    Frame Corlo 2-gang chrome-plated glossy
    12310
    70265 FRAME CORLO 2-GANG CHROME-PLATED GLOSSY VISUALIZATION
    12312 70266 Frame Corlo 3-gangs chrome-plated glossy VISUALIZATION
    Frame Corlo 3-gangs chrome-plated glossy
    12312
    70266 FRAME CORLO 3-GANGS CHROME-PLATED GLOSSY VISUALIZATION
    12968 30517 temperature sensors T-100. Cable length approx. 3m SENSORS
    Spare parts for temperature sensors KNX T-UN. Cable length approx. 3m
    12968
    30517 TEMPERATURE SENSORS T-100. CABLE LENGTH APPROX. 3M SENSORS
    12969 30518 temperature sensors T-130. Cable length approx. 3m SENSORS
    Spare parts for temperature sensors KNX T-UN. Cable length approx. 3m
    12969
    30518 TEMPERATURE SENSORS T-130. CABLE LENGTH APPROX. 3M SENSORS
    12970 30516 Temperature sensors T-NTC. Cable length approx. 3m SENSORS

    For use with Corlo Touch KNX-Display. For indoor and outdoor applications, with sensor sleeve. Cable length approx. 3m.

    12970
    30516 TEMPERATURE SENSORS T-NTC. CABLE LENGTH APPROX. 3M SENSORS
    16149 30146 Modbus Weather Stations SENSORS
    With 3 brightness sensors, wind sensor, heated precipitation sensor and outdoor temperature sensor.
    For Modbus. Operating voltage: 12-40 V DC (12-28 V AC). Combined fi xture for wall/pole mounting.
    P03/3-Modbus without reception of a time signal
    16149
    30146 MODBUS WEATHER STATIONS SENSORS
    16659 203 Group Control Relay, Housing IP54 SIN FAMILIA
    The WGGS-4 allows for operation of up to four drive mechanisms as a group. The relay with housing for surface mounting is installed in a not visible area (e.g. sub distributor, revision hatch).
    16659
    203 GROUP CONTROL RELAY, HOUSING IP54 SIN FAMILIA
    16923 30119 Mounting Arms for Weather Stations, Flex S 1 ball joint SIN FAMILIA

    For wall mounting. 1 ball joint (25°), total length approx. 64 mm. Powder-coated RAL 9003 (Signal

    white). For P03/Solexa/Suntracer, P04/Suntracer sl and Vari models.

    16923
    30119 MOUNTING ARMS FOR WEATHER STATIONS, FLEX S 1 BALL JOINT SIN FAMILIA
    17685 70205 KNX S1E-B4-UP PS Actuator, 4 A/D Inputs, with 24 V Power Supply ACTUATORS - OUTPUTS

    Actuator, 4 A/D Inputs, with 24 V Power Supply

      

     The Actuator KNX S1E-B4-UP PS with integrated façade controller regulates the 24 V DC motor for a shutter, an awning, a blind or window. The electronic output with polarity changer switches silently. An internal power supply transforms the 230 V AC mains voltage into 24 V DC to power the motor (500 mA maximum).

    The automation for the drive control is specified externally or internally. Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definitions (e.g. manual-automatic). Scenes are saved and called up via the bus (scene control with 16 scenes per drive).

    The KNX S1E-B4-UP PS has four inputs that are used as binary inputs (switches, alarm messages etc.) or as analogue inputs for T-NTC temperature sensors.

    17685
    70205 KNX S1E-B4-UP PS ACTUATOR, 4 A/D INPUTS, WITH 24 V POWER SUPPLY ACTUATORS - OUTPUTS
    17686 70381 KNX S2-B6 230 V, 2 MULTI FUNCTION outputs, 6 binary inputs ACTUATORS - OUTPUTS

    The KNX S-B 230 V Actuators with integrated facade control have got multifunctional outputs, pairs of buttons and monitoring LEDs. Each of the outputs can connect to either a drive with Up/Down control (blinds, awnings, shutters, windows) or two switchable devices (On/Off for light and ventilation). The connected drives and devices can be operated directly at the units and via hand switches.

    The automation can be specified externally or internally. Internally, there are numerous options available for blocking, locking (e.g. master-slave) and priority definition (e.g. manual – automatic). Scenes can be saved and called up via the bus (scene control with 16 scenes per drive).

    The binary inputs can be used either for direct operation (e.g. hand switches) or as bus switches (or also for e.g. alarm notifications). The desired behaviour can be defined precisely through selection of the response times in Standard, Comfort or Deadman mode

    17686
    70381 KNX S2-B6 230 V, 2 MULTI FUNCTION OUTPUTS, 6 BINARY INPUTS ACTUATORS - OUTPUTS
    17687 70204 KNX S1R-B4 PF KNX Actuator with Potential-Free Output ACTUATORS - OUTPUTS
    The actuator KNX S1R-B4 PF with integrated façade control has a multi-function output, to which either a drive with up / down control (blinds, awning, roller shutters, windows) or two switchable devices (on / off with light and ventilation) are connected will. Through the potential-free design of the output, other systems can also be controlled, eg via the hand-held input of a motor control unit.

    The automatic can be set externally or internally. There are numerous options for blocking, locking (eg master-slave) and priority settings (eg manual-automatic). Scenes can be stored and recalled via the bus (scene control with 16 scenes per drive).

    The KNX S1R-B4 PF has four analogue / digital inputs, which are used as bus inputs (push buttons, alarm messages, etc.) or for temperature sensors T-NTC
    17687
    70204 KNX S1R-B4 PF KNX ACTUATOR WITH POTENTIAL-FREE OUTPUT ACTUATORS - OUTPUTS
    17697 60124 WS1000 Color Building Control System 10 drive outputs 230 V VISUALIZATION

    Apart from shading and ventilation the WS1000 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting.
    Alongside the operating panel, the WS1000 Color provides a weather station and a radio-controlled indoor sensor. The indoor sensor is integrated in the switching series used in the building and perfectly merges with the interior. Various climate zones can be realised by installation of additional indoor sensors (single room control).
    The touch display makes operation of the WS1000 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow

    17697
    60124 WS1000 COLOR BUILDING CONTROL SYSTEM 10 DRIVE OUTPUTS 230 V VISUALIZATION
    17702 60145 WS1 Color-0, white, radio 230 V Building Control Systems VISUALIZATION

     

    Apart from shading and ventilation the WS1 Color also controls heatings and air conditioners. Motion and smoke detectors offer more safety and illumination at dawn creates atmospheric lighting. The WS1 Color includes the operating panel with integrated indoor sensor and the weather station. Further separate indoor sensors can be wirelessly integrated into the system and allow different climate zones to be created (individual room control).
    The touch display makes operation of the WS1 Color exceptionally easy and comfortable. A simple touch on the display buttons sets the function and moves the drives. In passive state the current weather is displayed: the sun travelling through the sky, rain or snow.

     

     

    17702
    60145 WS1 COLOR-0, WHITE, RADIO 230 V BUILDING CONTROL SYSTEMS VISUALIZATION
    17712 10144 selecta II display SIN FAMILIA

    System for control of shadings (awnings, blinds, shutters), windows, lights, heaters at Elsner RF radio

    actuators (16 radio outputs). Local operation and external temperature measurement with Elsner RF

    operating devices/sensors (32 radio inputs). Display and weather station as set, additional displays

    available.

    Touch display with integrated room temperature sensor for combination with weather station. Housing

    for surface mounting. Integrated battery, charging via USB cable (e. g. Nº 10155).

    Weather station for temperature, precipitation, wind speed, brightness (1 sun sensor), with GPS recei-

    ver. Connection for 230 V motor (integrated motor control unit). For combination with Solexa II displays

    (up to 4 pieces). Combined fixture for wall/pole. Operating voltage: 230 V AC

    17712
    10144 SELECTA II DISPLAY SIN FAMILIA
    17716 30136 P04i-GPS WEATHER STATION SIN FAMILIA
    The P04i-GPS weather station for WS1 and WS1000 Color/Style measures temperature, wind speed and brightness. It recognises precipitation and receives the GPS signal for time and location (international time signal and position).
    17716
    30136 P04I-GPS WEATHER STATION SIN FAMILIA
    17717 30137 P04i-W Wind Sensor Windsensor SIN FAMILIA
    Wind sensor for WS1 and WS1000 Color/Style and KNX WS1000 Style, in conjunction with P04i Data
    Collector. Operating voltage: 24 V DC. Combined fixture for wall/pole mounting
    17717
    30137 P04I-W WIND SENSOR WINDSENSOR SIN FAMILIA
    17720 30238 Connecting cable Corlo Touch – Push Buttons SIN FAMILIA
    Pre-assembled for easy connection of Corlo M1-T push buttons or Corlo M2-T push buttons to Display
    Corlo Touch KNX (WL)
    17720
    30238 CONNECTING CABLE CORLO TOUCH – PUSH BUTTONS SIN FAMILIA
    18068 SO250 0 Control module Depth gauge (without probe) SENSORS
    The KNX SO250 bus functions are set via the KNX software ETS. Five limits be set for filling, draining, dry run protection and overflow message. In addition, the KNX SO250 has a display, in which the distance/level is directly readable. The geometry of the tank and two relay switching outputs can be set using the integrated keypad. When switching the relays, an acoustic alarm signal may be issued in addition. The KNX SO250 basic has no display and no relay.
    18068
    SO250 0 CONTROL MODULE DEPTH GAUGE (WITHOUT PROBE) SENSORS
    18240 70152 SO250-UI Modbus Tank Senso SENSORS
    The SO250-UI ultrasonic probe is used for recording the amount of liquid filling in tanks and for measuring distances. Apart from areas of use such as storm water tanks or heating oil tanks, fish ponds, wells or the truck parking distance can also be monitored.
    The distance / fill level can be read directly on the display. The tank geometry and the relay switching outputs (modbus interface, current output, voltage output and two relay switching outputs) can be configured via the integrated keypad. When switching the relay, an acoustic alarm signal can be output.
    18240
    70152 SO250-UI MODBUS TANK SENSO SENSORS


    KNX SPECIAL CATALOGUES
    Different looks for KNX push buttons
    Push buttons
    Smart metering
    Iddero Verso Interactive Presentation

    LEARN
    Free webinars
    uBrick Tutorials
    VideoTutorials CBSE


    PARTICIPATE
    µBrick Trivia
    KNX Tips & tricks
    TEST
    Free test of CBSE visualization

    LATEST KNX NEWS
    All news

    LATEST KNX OFFERS
    All offers
    DOWNLOADS
    KNX - All brands

    FUTURASMUS KNX GROUP
    Contact
    Location
    Futurasmus in the world
    FOLLOW US
    YouTube Channel
    Facebook
    LinkedIN
    Google+
    Twitter

    KNX++ TRAINING CENTER
    Futurasmus Zentrum

    CERTIFIED KNX TEST LAB
    Futurasmus KNX Lab
    SPECIALIZED KNX WHOLESALER CERTIFIED KNX TRAINING CENTRE
    Futurasmus KNX Group is a highly specialized and internationally active KNX Wholesaler, being our forte the excellent technical support we provide. You can visit our online catalogue in this website and, if you are a professional, ask for a non binding offer for your KNX projects. Should you be interested in buying KNX components, you are welcome to read our General Sales Conditions and contact our technicians and commercial agents per telephone, e-mail or online help. Since 2003 we have been a Certified Training Centre KNX++, which means that we are entitled to impart the KNX Basic Course as well as the KNX Advanced Course and KNX Tutor Course. We are manufacturer-independent and also offer other specialized and monographic KNX seminars. After teaching more than 1.500 KNX partners, our KNX Trainers have quite a large and positive expertise. Please, contact us for customized KNX training worldwide (groups of at least 8 people) at training@futurasmus-knxgroup.org
    USE OF COOKIES
    We use our own and third-party cookies, analyzing your browsing habits in out website, with the finality of ensuring the quality, security and improvement of the offered services through the same. In the case that the user does not explicitly state whether to accept the installation of cookies, but continues using our website, it will mean that he has consented expressly, informing him about the possibility to block or remove the installed cookies on his computer by configuring the appropriate settings of the browser. You can get more information on this subject reading our "Cookies Policy".